The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Sensing through signal amplification
Abstract
The naked eye detection of single molecules in a complex mixture is the ultimate detection limit. Since a single molecule is unable to generate a strong enough signal, sensing methodologies able to reach that limit by necessity need to rely on signal amplification. This tutorial review describes various molecular approaches towards signal amplification in which a single analyte molecule affects the properties of a multitude of reporter molecules. Sensing by advanced instrumentation or changes in the physical properties of materials are excluded. The review is divided into four parts (catalysts, macromolecules, metal surfaces and supramolecular aggregates) depending on the species responsible for generating reporter molecules. Although on first sight apparently very diverse in nature, the majority of approaches rely on two key concepts: catalysis and multivalency. The ability of a catalyst to convert a multitude of substrate molecules into product (defined by the turn over number) makes a catalyst an intrinsic signal amplifier in case the chemical conversion of the substrate is accompanied by a measurable change in physical properties. For sensing purposes, catalytic activity must depend on the interaction between the analyte and the catalyst. Sensing using multivalent structures such as polymers and functionalized nanoparticles relies on the ability of a single analyte molecule to affect the properties of a multitude of reporter molecules collected in the multivalent structure. Chemical sensing systems will be discussed with detection limits that indeed go down to a few molecules and can rival the best biological assays. It will be shown that the most sensitive methods rely on a cascade of amplification mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Immunoassay of endogenous plasma insulin in man
Yalow, R. S., & Berson, S. A. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104130 · Cited by 3,041
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Applications of Nanoparticles in Biology
De, M., Ghosh, P. S., & Rotello, V. M. (2008) · Advanced Materials · doi:10.1002/adma.200703183 · Cited by 1,547
Asymmetric autocatalysis and amplification of enantiomeric excess of a chiral molecule
Soai, K., Shibata, T., Morioka, H., & Choji, K. (1995) · Nature · doi:10.1038/378767a0 · Cited by 1,085
Asymmetric Autocatalysis Triggered by Carbon Isotope ( 13 C/ 12 C) Chirality
Kawasaki, T., Matsumura, Y., Tsutsumi, T., Suzuki, K., Ito, M., & Soai, K. (2009) · Science · doi:10.1126/science.1170322 · Cited by 223
Signal Amplification by Allosteric Catalysis
Zhu, L., & Anslyn, E. V. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200501476 · Cited by 151
Cited by
Bissette, A. J., & Fletcher, S. P. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201303822 · Cited by 403
Shen, J., Li, Y., Gu, H., Xia, F., & Zuo, X. (2014) · Chemical Reviews · doi:10.1021/cr300248x · Cited by 273
Metadata
- Authors
- Scrimin, P., & Prins, L. J.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 40
- Issue
- 9
- Pages
- 4488
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2016494157
- Cited by
- 186
- References
- 7
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensing through signal amplification. https://app.cochat.ai/papers/10.1039/c1cs15024c
- The paper
- Scrimin, P., & Prins, L. J. (2011). Sensing through signal amplification. Chemical Society Reviews. https://doi.org/10.1039/c1cs15024c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.