A cell-based biosensor for real-time detection of cardiotoxicity using lensfree imaging
Open accessThe DOI matches its Crossref record.
Abstract
A portable and cost-effective real-time cardiotoxicity biosensor was developed using a CMOS imaging module extracted from a commercially available webcam. The detection system consists of a CMOS imaging module, a white LED and a pinhole. Real-time image processing was conducted by comparing reference and live frame images. To evaluate the engineered system, the effects of two different drugs, isoprenaline and doxorubicin, on the beating rate and beat-to-beat variations of ESC-derived cardiomyocytes were measured. The detection system was used to conclude that the beat-to-beat variability increased under treatment with both isoprenaline and doxorubicin. However, the beating rates increased upon the addition of isoprenaline but decreased for cultures supplemented with doxorubicin. Moreover, the response time for both the beating rates and the beat-to-beat variability of ESC-derived cardiomyocytes under treatment of isoprenaline was shorter than for doxorubicin, although the amount of isoprenaline used in the measurement was three orders of magnitude lower than that of doxorubicin. Given its ability to perform real-time cell monitoring in a simple and inexpensive manner, the proposed system may be useful for a range of cell-based biosensing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioprinting 3D microfibrous scaffolds for engineering endothelialized myocardium and heart-on-a-chip
Zhang, Y. S., Arneri, A., Bersini, S., Shin, S.-R., Zhu, K., Goli-Malekabadi, Z., Aleman, J., Colosi, C., Busignani, F., Dell'Erba, V., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.09.003 · Cited by 951
Self-citationCarbon-Nanotube-Embedded Hydrogel Sheets for Engineering Cardiac Constructs and Bioactuators
Shin, S. R., Jung, S. M., Zalabany, M., Kim, K., Zorlutuna, P., Kim, S. B., Nikkhah, M., Khabiry, M., Azize, M., Kong, J., et al. (2013) · ACS Nano · doi:10.1021/nn305559j · Cited by 946
“, Natick, MA).(45) First, the reference image, which was taken from the first frame, and the images from consecutive frames were transformed to binary images and stored as two different matrices.”
Self-citationThree-Dimensional Cell Cultures in Drug Discovery and Development
Fang, Y., & Eglen, R. M. (2017) · SLAS Discovery · doi:10.1177/1087057117696795 · Cited by 849
“Heart-on-achip devices were useful for assessing drug-induced cardiotoxicity.(60,61) The lung-on-chip model developed by Huh et al.”
MethodOrganoid-on-a-chip and body-on-a-chip systems for drug screening and disease modeling
Skardal, A., Shupe, T., & Atala, A. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.07.003 · Cited by 512
“Significant reduction of size, together with improvements in biosensing and diagnostic technology [72,73,85], (S.”
BackgroundOptical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Metadata
- Authors
- Kim, S. B., Bae, H., Cha, J. M., Moon, S. J., Dokmeci, M. R., Cropek, D. M., & Khademhosseini, A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 10
- Pages
- 1801
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1990573381
- Cited by
- 96
- References
- 0
- FWCI
- 6.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A cell-based biosensor for real-time detection of cardiotoxicity using lensfree imaging. https://app.cochat.ai/papers/10.1039/c1lc20098d
- The paper
- Kim, S. B., Bae, H., Cha, J. M., Moon, S. J., Dokmeci, M. R., Cropek, D. M., & Khademhosseini, A. (2011). A cell-based biosensor for real-time detection of cardiotoxicity using lensfree imaging. Lab on a Chip. https://doi.org/10.1039/c1lc20098d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.