Miniature magnetic resonance system for point-of-care diagnostics
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We have developed a next generation, miniaturized platform to diagnose disease at the point-of-care using diagnostic magnetic resonance (DMR-3). Utilizing a rapidly growing library of functionalized magnetic nanoparticles, DMR has previously been demonstrated as a versatile tool to quantitatively and rapidly detect disease biomarkers in unprocessed biological samples. A major hurdle for bringing DMR to the point-of-care has been its sensitivity to temperature variation. As an alternative to costly and bulky mechanisms to control temperature, we have implemented an automated feedback system to track and compensate for the temperature drift, which enables reliable and robust DMR measurements in realistic clinical environments (4-50 °C). Furthermore, the new system interfaces with a mobile device to facilitate system control and data sharing over wireless networks. With such features, the DMR-3 platform can function as a self-contained laboratory even in resource-limited, remote settings. The clinical potential of the new system is demonstrated by detecting trace amounts of proteins and as few as 10 bacteria (Staphylococcus aureus) in a short time frame (<30 min).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Chip–NMR biosensor for detection and molecular analysis of cells
Lee, H., Sun, E., Ham, D., & Weissleder, R. (2008) · Nature Medicine · doi:10.1038/nm.1711 · Cited by 621
Self-citation
Cited by
Protein typing of circulating microvesicles allows real-time monitoring of glioblastoma therapy
Shao, H., Chung, J., Balaj, L., Charest, A., Bigner, D. D., Carter, B. S., Hochberg, F. H., Breakefield, X. O., Weissleder, R., & Lee, H. (2012) · Nature Medicine · doi:10.1038/nm.2994 · Cited by 759
Self-citationNanoparticle-Based Immunochemical Biosensors and Assays: Recent Advances and Challenges
Farka, Z., Juřík, T., Kovář, D., Trnková, L., & Skládal, P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00037 · Cited by 694
Structure–Relaxivity Relationships of Magnetic Nanoparticles for Magnetic Resonance Imaging
Zhou, Z., Yang, L., Gao, J., & Chen, X. (2019) · Advanced Materials · doi:10.1002/adma.201804567 · Cited by 488
Point-of-care microfluidic devices for pathogen detection
Nasseri, B., Soleimani, N., Rabiee, N., Kalbasi, A., Karimi, M., & Hamblin, M. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.050 · Cited by 382
Point of care testing: The impact of nanotechnology
Syedmoradi, L., Daneshpour, M., Alvandipour, M., Gomez, F. A., Hajghassem, H., & Omidfar, K. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.084 · Cited by 367
Lin, S., Yu, Z., Chen, D., Wang, Z., Miao, J., Li, Q., Zhang, D., Song, J., & Cui, D. (2020) · Small · doi:10.1002/smll.201903916 · Cited by 353
A magneto-DNA nanoparticle system for rapid detection and phenotyping of bacteria
Chung, H. J., Castro, C. M., Im, H., Lee, H., & Weissleder, R. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.70 · Cited by 339
Self-citationRecent Developments in Magnetic Diagnostic Systems
Lee, H., Shin, T.-H., Cheon, J., & Weissleder, R. (2015) · Chemical Reviews · doi:10.1021/cr500698d · Cited by 292
Self-citationDevelopment and Applications of Portable Biosensors
Srinivasan, B., & Tung, S. (2015) · SLAS Technology · doi:10.1177/2211068215581349 · Cited by 262
van Reenen, A., de Jong, A. M., den Toonder, J. M. J., & Prins, M. W. J. (2014) · Lab Chip · doi:10.1039/c3lc51454d · Cited by 262
Diagnostic and Prognostic Potential of Extracellular Vesicles in Peripheral Blood
Revenfeld, A. L. S., Bæk, R., Nielsen, M. H., Stensballe, A., Varming, K., & Jørgensen, M. (2014) · Clinical Therapeutics · doi:10.1016/j.clinthera.2014.05.008 · Cited by 258
Combining Machine Learning and Nanofluidic Technology To Diagnose Pancreatic Cancer Using Exosomes
Ko, J., Bhagwat, N., Yee, S. S., Ortiz, N., Sahmoud, A., Black, T., Aiello, N. M., McKenzie, L., O’Hara, M., Redlinger, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b05503 · Cited by 249
Self-citationOliveira‐Rodríguez, M., López‐Cobo, S., Reyburn, H. T., Costa‐García, A., López‐Martín, S., Yáñez‐Mó, M., Cernuda‐Morollón, E., Paschen, A., Valés‐Gómez, M., & Blanco‐López, M. C. (2016) · Journal of Extracellular Vesicles · doi:10.3402/jev.v5.31803 · Cited by 173
Kaplan, R. M., & Stone, A. A. (2013) · Annual Review of Psychology · doi:10.1146/annurev-psych-113011-143736 · Cited by 144
The use of magnetic nanoparticles in cancer theranostics: Toward handheld diagnostic devices
Hajba, L., & Guttman, A. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.02.001 · Cited by 111
Cancer Extracellular Vesicles: Next-Generation Diagnostic and Drug Delivery Nanotools
Palazzolo, S., Memeo, L., Hadla, M., Duzagac, F., Steffan, A., Perin, T., Canzonieri, V., Tuccinardi, T., Caligiuri, I., & Rizzolio, F. (2020) · Cancers · doi:10.3390/cancers12113165 · Cited by 34
Metadata
- Authors
- Issadore, D., Min, C., Liong, M., Chung, J., Weissleder, R., & Lee, H.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 13
- Pages
- 2282
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2120390535
- Cited by
- 150
- References
- 2
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.