The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Enhanced cell sorting and manipulation with combined optical tweezer and microfluidic chip technologies
Abstract
Sorting (or isolation) and manipulation of rare cells with high recovery rate and purity are of critical importance to a wide range of physiological applications. In the current paper, we report on a generic single cell manipulation tool that integrates optical tweezers and microfluidic chip technologies for handling small cell population sorting with high accuracy. The laminar flow nature of microfluidics enables the targeted cells to be focused on a desired area for cell isolation. To recognize the target cells, we develop an image processing methodology with a recognition capability of multiple features, e.g., cell size and fluorescence label. The target cells can be moved precisely by optical tweezers to the desired destination in a noninvasive manner. The unique advantages of this sorter are its high recovery rate and purity in small cell population sorting. The design is based on dynamic fluid and dynamic light pattern, in which single as well as multiple laser traps are employed for cell transportation, and a recognition capability of multiple cell features. Experiments of sorting yeast cells and human embryonic stem cells are performed to demonstrate the effectiveness of the proposed cell sorting approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Embryonic Stem Cell Lines Derived from Human Blastocysts
Thomson, J. A., Itskovitz-Eldor, J., Shapiro, S. S., Waknitz, M. A., Swiergiel, J. J., Marshall, V. S., & Jones, J. M. (1998) · Science · doi:10.1126/science.282.5391.1145 · Cited by 15,926
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Biological Applications of Optical Forces
Svoboda, K., & Block, S. M. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.001335 · Cited by 1,792
Forces of a single-beam gradient laser trap on a dielectric sphere in the ray optics regime
Ashkin, A. (1992) · Biophysical Journal · doi:10.1016/s0006-3495(92)81860-x · Cited by 1,681
Massively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444
Microfluidic sorting in an optical lattice
MacDonald, M. P., Spalding, G. C., & Dholakia, K. (2003) · Nature · doi:10.1038/nature02144 · Cited by 1,246
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Microfluidic sorting of mammalian cells by optical force switching
Wang, M. M., Tu, E., Raymond, D. E., Yang, J. M., Zhang, H., Hagen, N., Dees, B., Mercer, E. M., Forster, A. H., Kariv, I., et al. (2005) · Nature Biotechnology · doi:10.1038/nbt1050 · Cited by 690
Laser-Induced Heating in Optical Traps
Peterman, E. J. G., Gittes, F., & Schmidt, C. F. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74946-7 · Cited by 608
Xue, T., Cho, H. C., Akar, F. G., Tsang, S.-Y., Jones, S. P., Marbán, E., Tomaselli, G. F., & Li, R. A. (2005) · Circulation · doi:10.1161/01.cir.0000151313.18547.a2 · Cited by 480
Self-citationPetersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T. (2005) · Lab Chip · doi:10.1039/b405748c · Cited by 360
Continuous microfluidic immunomagnetic cell separation
Inglis, D. W., Riehn, R., Austin, R. H., & Sturm, J. C. (2004) · Applied Physics Letters · doi:10.1063/1.1823015 · Cited by 353
Optical tweezers applied to a microfluidic system
Enger, J., Goksör, M., Ramser, K., Hagberg, P., & Hanstorp, D. (2004) · Lab Chip · doi:10.1039/b307960k · Cited by 245
Automated trapping, assembly, and sorting with holographic optical tweezers
Chapin, S. C., Germain, V., & Dufresne, E. R. (2006) · Optics Express · doi:10.1364/oe.14.013095 · Cited by 205
Microfluidic sorting system based on optical waveguide integration and diode laser bar trapping
Applegate Jr., R. W., Squier, J., Vestad, T., Oakey, J., Marr, D. W. M., Bado, P., Dugan, M. A., & Said, A. A. (2006) · Lab on a Chip · doi:10.1039/b512576f · Cited by 191
Tan, Y., Sun, D., Wang, J., & Huang, W. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2042448 · Cited by 158
Self-citationArai, F., Ichikawa, A., Ogawa, M., Fukuda, T., Horio, K., & Itoigawa, K. (2001) · Electrophoresis · Cited by 148
Yao, B., Luo, G., Feng, X., Wang, W., Chen, L.-X., & Wang, Y. (2004) · Lab on a Chip · doi:10.1039/b408422e · Cited by 139
Mechanical force characterization in manipulating live cells with optical tweezers
Wu, Y., Sun, D. B., & Huang, W. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.10.034 · Cited by 103
Self-citationMicrofluidic-Based Cell Sorting of Francisella tularensis Infected Macrophages Using Optical Forces
Perroud, T. D., Kaiser, J. N., Sy, J. C., Lane, T. W., Branda, C., Singh, A. K., & Patel, K. D. (2008) · Analytical Chemistry · doi:10.1021/ac8007779 · Cited by 93
Fractionation of polydisperse colloid with acousto-optically generated potential energy landscapes
Milne, G., Rhodes, D. P., MacDonald, M. P., & Dholakia, K. (2007) · Optics Letters · doi:10.1364/ol.32.001144 · Cited by 87
Optical manipulation and microfluidics for studies of single cell dynamics
Eriksson, E., Scrimgeour, J., Granéli, A., et al. (2007) · Journal of Optics A Pure and Applied Optics · doi:10.1088/1464-4258/9/8/s02 · Cited by 65
Mechanical Modeling of Red Blood Cells During Optical Stretching
Tan, Y., Sun, D. B., & Huang, W. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4001042 · Cited by 31
Self-citation
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Self-citationInnovations to culturing the uncultured microbial majority
Lewis, W. H., Tahon, G., Geesink, P., Sousa, D. Z., & Ettema, T. J. G. (2021) · Nature Reviews Microbiology · doi:10.1038/s41579-020-00458-8 · Cited by 605
Guidelines for the use of flow cytometry and cell sorting in immunological studies *
Cossarizza, A., Chang, H., Radbruch, A., Akdis, M., Andrä, I., Annunziato, F., Bacher, P., Barnaba, V., Battistini, L., Bauer, W. M., et al. (2017) · European Journal of Immunology · doi:10.1002/eji.201646632 · Cited by 542
Optical tweezers — from calibration to applications: a tutorial
Gieseler, J., Gomez-Solano, J. R., Magazzù, A., Pérez Castillo, I., Pérez García, L., Gironella-Torrent, M., Viader-Godoy, X., Ritort, F., Pesce, G., Arzola, A. V., et al. (2021) · Advances in Optics and Photonics · doi:10.1364/aop.394888 · Cited by 282
Metadata
- Authors
- Wang, X., Chen, S., Kong, M., Wang, Z., Costa, K. D., Li, R. A., & Sun, D.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 21
- Pages
- 3656
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2017348445
- Cited by
- 440
- References
- 23
- FWCI
- 14.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.