Integration of intra- and extravasation in one cell-based microfluidic chip for the study of cancer metastasis
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Most studies of cancer metastasis focus on cancer cell invasion utilizing adhesion assays that are performed independently, and are thus limited in their ability to mimic complex cancer metastasis on a chip. Here we report the development of an integrated cell-based microfluidic chip for intra- and extravasation that combines two assays on one chip for the study of the complex cascade of cancer metastasis. This device consists of two parts; one is an intravasation chamber for the three-dimensional (3-D) culture of cancer cells using a Matrigel matrix, and the other is an extravasation chamber for the detection of metastasized cancer cells by adhesion molecules expressed by epithelial cells. In this novel system, the intravasation and extravasation processes of cancer metastasis can be studied simultaneously using four screw valves. Metastatic LOVO and non-metastatic SW480 cells were used in this study, and the invasion of LOVOs was found to be higher compared to SW480. In contrast, invasion of cells treated with metalloproteinase (MMP) inhibitors decreased within the intravasation chamber. Degraded cancer cells from the intravasation chamber were detected within the extravasation chamber under physiological conditions of shear stress, and differences in binding efficiency were also detected when CA19-9 antibody, an inhibitor of cancer cell adhesion, was used to treat degraded cancer cells. Our results support the potential usefulness of this new 3D cell-based microfluidic system as a drug screening tool to select targets for the development of new drugs and to verify their effectiveness.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Microfluidic assays have been designed to replicate certain aspects of several of these steps, such as EMT[13, 14], cancer cell invasion and adhesion[15–17], and intra-[18, 19] and extravasation[17, 20– 22] (see Text Box 3).”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [16]
Citations
Cites
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Metastasis: from dissemination to organ-specific colonization
Nguyen, D. X., Bos, P. D., & Massagué, J. (2009) · Nature Reviews Cancer · doi:10.1038/nrc2622 · Cited by 2,649
Zaman, M. H., Trapani, L. M., Sieminski, A. L., MacKellar, D., Gong, H., Kamm, R. D., Wells, A., Lauffenburger, D. A., & Matsudaira, P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604460103 · Cited by 1,160
Matrix metalloproteinases: multifunctional contributors to tumor progression
McCawley, L. J., & Matrisian, L. M. (2000) · Molecular Medicine Today · doi:10.1016/s1357-4310(00)01686-5 · Cited by 643
General mechanisms of metastasis
Woodhouse, E. C., Chuaqui, R. F., & Liotta, L. A. (1997) · Cancer · doi:10.1002/(sici)1097-0142(19971015)80:8+<1529::aid-cncr2>3.3.co;2-# · Cited by 609
General mechanisms of metastasis
Woodhouse, E. C., Chuaqui, R. F., & Liotta, L. A. (1997) · Cancer · doi:10.1002/(sici)1097-0142(19971015)80:8+<1529::aid-cncr2>3.0.co;2-f · Cited by 581
Cell migration into scaffolds under co-culture conditions in a microfluidic platform
Chung, S., Sudo, R., Mack, P. J., Wan, C.-R., Vickerman, V., & Kamm, R. D. (2009) · Lab Chip · doi:10.1039/b807585a · Cited by 519
The role of gelatinases in colorectal cancer progression and metastasis
Mook, O. R. F., Frederiks, W. M., & Van Noorden, C. J. F. (2004) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2004.09.006 · Cited by 511
Critical determinants of metastasis
Fidler, I. J. (2002) · Seminars in Cancer Biology · doi:10.1006/scbi.2001.0416 · Cited by 413
Microfluidic Shear Devices for Quantitative Analysis of Cell Adhesion
Lu, H., Koo, L. Y., Wang, W. M., Lauffenburger, D. A., Griffith, L. G., & Jensen, K. F. (2004) · Analytical Chemistry · doi:10.1021/ac049837t · Cited by 405
Research works printed but not linked: 2
- Chakravorty, 2006, Biorheology, 43, 71
- Sul, 1995, Journal of Korean cancer association, 27, 209
Cited by
Biofabrication: A Guide to Technology and Terminology
Moroni, L., Boland, T., Burdick, J. A., De Maria, C., Derby, B., Forgacs, G., Groll, J., Li, Q., Malda, J., Mironov, V. A., et al. (2018) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.10.015 · Cited by 636
A microfluidic 3D in vitro model for specificity of breast cancer metastasis to bone
Bersini, S., Jeon, J. S., Dubini, G., Arrigoni, C., Chung, S., Charest, J. L., Moretti, M., & Kamm, R. D. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.050 · Cited by 534
Chen, M. B., Whisler, J. A., Fröse, J., Yu, C., Shin, Y., & Kamm, R. D. (2017) · Nature Protocols · doi:10.1038/nprot.2017.018 · Cited by 385
Chiang, S. P. H., Cabrera, R. M., & Segall, J. E. (2016) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00238.2015 · Cited by 311
Gut-on-a-chip: Current progress and future opportunities
Ashammakhi, N., Nasiri, R., Barros, N. R. D., Tebon, P., Thakor, J., Goudie, M., Shamloo, A., Martin, M. G., & Khademhosseini, A. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120196 · Cited by 235
Rizvi, I., Gurkan, U. A., Tasoglu, S., Alagic, N., Celli, J. P., Mensah, L. B., Mai, Z., Demirci, U., & Hasan, T. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1216989110 · Cited by 234
“Microfluidic systems also have been used to mimic intravasation and extravasation to study cancer metastasis (69, 70).”
MethodIn vitro model of tumor cell extravasation
Jeon, J. S., Zervantonakis, I. K., Chung, S., Kamm, R. D., & Charest, J. L. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056910 · Cited by 233
“Recent studies have begun to address this need using advanced microfluidics [21,22,23], but each is has In Vitro Model of Tumor Cell Extravasation”
BackgroundMicrofluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
Biomedical Applications of Microfluidic Devices: A Review
Gharib, G., Bütün, İ., Muganlı, Z., Kozalak, G., Namlı, İ., Sarraf, S. S., Ahmadi, V. E., Toyran, E., van Wijnen, A. J., & Koşar, A. (2022) · Biosensors · doi:10.3390/bios12111023 · Cited by 215
Chen, Y.-C., Allen, S. G., Ingram, P. N., Buckanovich, R., Merajver, S. D., & Yoon, E. (2015) · Scientific Reports · doi:10.1038/srep09980 · Cited by 163
Vasculature-On-A-Chip for In Vitro Disease Models
Kim, S., Kim, W., Lim, S., & Jeon, J. (2017) · Bioengineering · doi:10.3390/bioengineering4010008 · Cited by 157
Self-citationBone-on-a-chip: Microfluidic technologies and microphysiologic models of bone tissue
Mansoorifar, A., Gordon, R., Bergan, R. C., & Bertassoni, L. E. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202006796 · Cited by 142
Bioengineering 3D environments for cancer models
Alemany‐Ribes, M., & Semino, C. E. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.06.004 · Cited by 151
Applications of Microfluidics and Organ-on-a-Chip in Cancer Research
Regmi, S., Poudel, C., Adhikari, R., & Luo, K. Q. (2022) · Biosensors · doi:10.3390/bios12070459 · Cited by 143
Pisano, M., Triacca, V., Barbee, K. A., & Swartz, M. A. (2015) · Integrative Biology · doi:10.1039/c5ib00085h · Cited by 114
França, C. M., Tahayeri, A., Rodrigues, N. S., Ferdosian, S., Puppin‐Rontani, R. M., Sereda, G. A., Ferracane, J. L., & Bertassoni, L. E. (2019) · Lab on a Chip · doi:10.1039/c9lc00915a · Cited by 128
The Gut–Organ-Axis Concept: Advances the Application of Gut-on-Chip Technology
Guo, Y., Chen, X., Gong, P., Li, G., Yao, W., & Yang, W. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24044089 · Cited by 114
“These GOC systems will help improve the understanding and treatment of common diseases such as inflammatory bowel disease (IBD) [50] and colorectal cancer [51].”
BackgroundEngineering 3D approaches to model the dynamic microenvironments of cancer bone metastasis
Qiao, H., & Tang, T. (2018) · Bone Research · doi:10.1038/s41413-018-0008-9 · Cited by 108
“Additionally, a cell-based microfluidic chip was devised in which both the intravasation and extravasation processes in metastasis could simultaneously reappear, demonstrating the detachment of malignant cells from the Matrigel matrix under sheer stress in the intravasation chamber, followed by the attachment to adhes…”
Choi, H., & Moon, A. (2018) · Archives of Pharmacal Research · doi:10.1007/s12272-018-1051-1 · Cited by 98
Microfluidics for studying metastatic patterns of lung cancer
Ruzycka, M., Cimpan, M. R., Rios-Mondragon, I., & Grudzinski, I. P. (2019) · Journal of Nanobiotechnology · doi:10.1186/s12951-019-0492-0 · Cited by 82
3D in vitro tissue models and their potential for drug screening
Kimlin, L., Kassis, J., & Virador, V. (2013) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2013.852181 · Cited by 79
“Overall metastasis potential was determined by the ability of metastatic cells to adhere to endothelial cells (EGFR-FITC antibody selectively binds to the cancer cells in the cluster) followed by the recovery of single cancer cells out of the extravasation chamber under constant fluid flow [20].”
BackgroundWang, X.-Y., Pei, Y., Xie, M., Jin, Z.-H., Xiao, Y.-S., Wang, Y., Zhang, L.-N., Li, Y., & Huang, W.-H. (2015) · Lab on a Chip · doi:10.1039/c4lc00973h · Cited by 77
Physical Biology in Cancer. 4. Physical cues guide tumor cell adhesion and migration
Stroka, K. M., & Konstantopoulos, K. (2014) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00289.2013 · Cited by 76
Paschos, K. A., Majeed, A. W., & Bird, N. C. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i14.3719 · Cited by 89
A novel microfluidic model can mimic organ-specific metastasis of circulating tumor cells
Kong, J., Luo, Y., Jin, D., An, F., Zhang, W., Liu, L., Li, J., Fang, S., Li, X., Yang, X., et al. (2016) · Oncotarget · doi:10.18632/oncotarget.9382 · Cited by 72
In vitro models of the metastatic cascade: from local invasion to extravasation
Bersini, S., Jeon, J. S., Moretti, M., & Kamm, R. D. (2014) · Drug Discovery Today · doi:10.1016/j.drudis.2013.12.006 · Cited by 71
“(e) Microfluidic platform for the study of intraand extravasation events [59].”
BackgroundPozzi, S., Scomparin, A., Dangoor, S. I., Ajamil, D. R., Ofek, P., Neufeld, L., Krivitsky, A., Vaskovich‐Koubi, D., Kleiner, R., Dey, P., et al. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.04.001 · Cited by 79
Emerging tumor-on-chips with electrochemical biosensors
Lei, L., Ma, B., Xu, C., & Liu, H. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116640 · Cited by 72
Cell chips as new tools for cell biology – results, perspectives and opportunities
Primiceri, E., Chiriacò, M. S., Rinaldi, R., & Maruccio, G. (2013) · Lab on a Chip · doi:10.1039/c3lc50550b · Cited by 61
A microfluidic model for organ-specific extravasation of circulating tumor cells
Riahi, R., Yang, Y. L., Kim, H., Jiang, L., Wong, P. K., & Zohar, Y. (2014) · Biomicrofluidics · doi:10.1063/1.4868301 · Cited by 60
Biofabrication Strategies and Engineered In Vitro Systems for Vascular Mechanobiology
Pradhan, S., Banda, O. A., Farino, C. J., Sperduto, J. L., Keller, K. A., Taitano, R. A., & Slater, J. H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901255 · Cited by 64
The Use of Microfluidic Platforms to Probe the Mechanism of Cancer Cell Extravasation
Coughlin, M. F., & Kamm, R. D. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901410 · Cited by 60
A microfluidic co-culture system to monitor tumor-stromal interactions on a chip
Menon, N. V., Chuah, Y. J., Cao, B., Lim, M., & Kang, Y. (2014) · Biomicrofluidics · doi:10.1063/1.4903762 · Cited by 53
Zhang, X., Huang, Y., Song, H., Canup, B. S. B., Gou, S., She, Z., Dai, F., Ke, B., & Xiao, B. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.08.066 · Cited by 56
Modelling the metastatic cascade by in vitro microfluidic platforms
Samatov, T. R., Shkurnikov, M. Y., Tonevitskaya, S. A., & Tonevitsky, A. (2015) · Progress in Histochemistry and Cytochemistry · doi:10.1016/j.proghi.2015.01.001 · Cited by 56
“A combined system for both intravasation and extravasation in a single chip was established using the colon cancer metastatic LOVO cells and non-metastatic SW480 cells and human umbilical vein endothelial cells (HUVECs) (Shin et al., 2011).”
BackgroundVisualizing cancer extravasation: from mechanistic studies to drug development
Cheng, X., & Cheng, K. (2020) · Cancer and Metastasis Reviews · doi:10.1007/s10555-020-09942-2 · Cited by 53
Humayun, M., Ayuso, J. M., Brenneke, R. A., Virumbrales-Muñoz, M., Lugo-Cintrón, K., Kerr, S., Ponik, S. M., & Beebe, D. J. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2020.120640 · Cited by 46
Macaraniag, C., Luan, Q., Zhou, J., & Papautsky, I. (2022) · APL Bioengineering · doi:10.1063/5.0093806 · Cited by 50
Biomimetic tumor microenvironment on a microfluidic platform
Ma, H., Xu, H., & Qin, J. (2013) · Biomicrofluidics · doi:10.1063/1.4774070 · Cited by 46
Kucińska, M., Murias, M., & Nowak-Sliwinska, P. M. (2016) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2016.09.002 · Cited by 41
Virumbrales-Muñoz, M., Ayuso, J. M., Lacueva, A., Randelovic, T., Livingston, M. K., Beebe, D. J., Oliván, S., Pereboom, D., Doblare, M., Fernández, L., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-42529-8 · Cited by 41
A Microfluidic System for the Investigation of Tumor Cell Extravasation
Kühlbach, C., Da Luz, S., Baganz, F., Hass, V. C., & Mueller, M. M. (2018) · Bioengineering · doi:10.3390/bioengineering5020040 · Cited by 38
“Independent of the model geometry or of the type of endothelial cells that are used, most of these devices are made of Polydimethylsiloxane (PDMS), which is frequently activated by plasma-treatment and is bonded to glass [17,31,33,34].”
BackgroundMethodInfluentialCancer Metastasis‐on‐a‐Chip for Modeling Metastatic Cascade and Drug Screening
Brooks, A., Zhang, Y., Chen, J., & Zhao, C. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202302436 · Cited by 44
3D functional and perfusable microvascular networks for organotypic microfluidic models
Bersini, S., & Moretti, M. (2015) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-015-5520-5 · Cited by 44
A microfluidic device for isolation and characterization of transendothelial migrating cancer cells
Cui, X., Guo, W., Sun, Y., Sun, B., Hu, S., Sun, D., & Lam, R. H. W. (2017) · Biomicrofluidics · doi:10.1063/1.4974012 · Cited by 37
In vitro Studies of Transendothelial Migration for Biological and Drug Discovery
Salminen, A. T., Allahyari, Z., Gholizadeh, S., McCloskey, M. C., Ajalik, R. E., Cottle, R. N., Gaborski, T. R., & McGrath, J. L. (2020) · Frontiers in Medical Technology · doi:10.3389/fmedt.2020.600616 · Cited by 47
Microfluidic applications on circulating tumor cell isolation and biomimicking of cancer metastasis
Xu, X., Jiang, Z., Wang, J., Ren, Y., & Wu, A. (2020) · Electrophoresis · doi:10.1002/elps.201900402 · Cited by 38
Bertulli, C., Gerigk, M., Piano, N., Liu, Y., Zhang, D., Müller, T., Knowles, T. P. J., & Huang, Y. Y. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-30776-0 · Cited by 36
Wang, R., Zhang, C., Li, D., & Yao, Y. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.1057913 · Cited by 33
Angeli, S., Neophytou, C., Kalli, M., Stylianopoulos, T., & Mpekris, F. (2025) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2025.1564626 · Cited by 41
Wei, M., Zhang, R., Zhang, F., Zhang, Y., Li, G., Miao, R., & Shao, S. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01061 · Cited by 28
High‐Throughput Cellular Heterogeneity Analysis in Cell Migration at the Single‐Cell Level
Zhou, M., Ma, Y., Chiang, C., Rock, E. C., Luker, K. E., Luker, G. D., & Chen, Y. (2022) · Small · doi:10.1002/smll.202206754 · Cited by 28
Yamamoto, S., Hotta, M. M., Okochi, M., & Honda, H. (2014) · PLoS ONE · doi:10.1371/journal.pone.0103502 · Cited by 32
“Although current invasive studies using 3D microfluidic models have been developed to overcome these limitations [5,22,23], such studies are largely”
BackgroundHu, W., Wang, Y., Han, J., Zhang, W., Chen, J., Li, X., & Wang, L. (2025) · Biomaterials Science · doi:10.1039/d4bm01273a · Cited by 30
Vitale, C., Fedi, A., Marrella, A., Varani, G., Fato, M., & Scaglione, S. (2020) · Polymers · doi:10.3390/polym12112467 · Cited by 24
Dynamic in vitro models for tumor tissue engineering
Karami, D., Richbourg, N. R., & Sikavitsas, V. I. (2019) · Cancer Letters · doi:10.1016/j.canlet.2019.01.043 · Cited by 28
Hydrogels as a New Platform to Recapitulate the Tumor Microenvironment
Ermis, M., Çalamak, S., Calibasi‐Kocal, G., Güven, S., Durmus, N. G., Rizvi, I., Hasan, T. G., Hasırcı, N., Hasırcı, V., & Demirci, U. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813339-2.00015-3 · Cited by 39
Gao, A., Tian, Y., Shi, Z., & Yu, L. D. (2015) · BioChip Journal · doi:10.1007/s13206-016-0108-9 · Cited by 18
Kaiser, K. N., Snyder, J. R., Koppes, R. A., & Koppes, A. N. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202409718 · Cited by 17
Tissue engineering perfusable cancer models
Fong, E. L. S., Santoro, M. M., Farach‐Carson, M. C., Kasper, F. K., & Mikos, A. G. (2014) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2013.12.008 · Cited by 17
Weller, A., Hansen, M. B., Marie, R., Hundahl, A. C., Hempel, C., Kempen, P. J., Frandsen, H. L., Parhamifar, L., Larsen, J. B., & Andresen, T. L. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.965200 · Cited by 13
A Versatile Microfluidic Platform for Extravasation Studies Based on DNA Origami—Cell Interactions
García‐Chamé, M., Wadhwani, P., Pfeifer, J., Schepers, U., Niemeyer, C. M., & Domínguez, C. M. (2024) · Angewandte Chemie International Edition · doi:10.1002/anie.202318805 · Cited by 15
Unraveling Cancer Metastatic Cascade Using Microfluidics-based Technologies
Hakim, M., Kermanshah, L., Abouali, H., Hashemi, H. M., Yari, A., Khorasheh, F., Alemzadeh, I., & Vossoughi, M. (2022) · Biophysical Reviews · doi:10.1007/s12551-022-00944-8 · Cited by 15
“Consequently, matrix degradation by invasive cancer cells was suggested to be an important factor in producing high intravasation rates (Shin et al. 2011).”
BackgroundAdvancements in Three Dimensional In‐Vitro Cell Culture Models
De, S., & Singh, N. (2022) · The Chemical Record · doi:10.1002/tcr.202200058 · Cited by 12
Zhou, M., Ma, Y., Rock, E. C., Chiang, C., Luker, K. E., Luker, G. D., & Chen, Y. (2023) · Lab on a Chip · doi:10.1039/d3lc00651d · Cited by 12
Boussommier-Calleja, A. (2020) · Bioengineering Innovative Solutions for Cancer · doi:10.1016/b978-0-12-813886-1.00013-9 · Cited by 10
Application of microfluidic technology in cancer research and therapy
Azadi, S., Es, H. A., Kulasinghe, A., Bordhan, P., & Warkiani, M. E. (2020) · Advances in clinical chemistry · doi:10.1016/bs.acc.2020.02.012 · Cited by 12
Microfluidic Applications in Prostate Cancer Research
Szewczyk, K., Jiang, L., Khawaja, H., Miranti, C. K., & Zohar, Y. (2024) · Micromachines · doi:10.3390/mi15101195 · Cited by 9
Mayo, L. N., & Kutys, M. L. (2022) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00173.2022 · Cited by 9
Engineered Models of Metastasis with Application to Study Cancer Biomechanics
Chen, M. B., Kamm, R. D., & Moeendarbary, E. (2018) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-95294-9_10 · Cited by 8
“In a microfluidic endothelial layer model developed by Shin et al, it was found that following intravasation, tumor cells adhered and arrested on the endothelium and that E-selectin expression dictated the level stable attachment of tumor cells under shear flow conditions(86).”
BackgroundMethodPatch type sensor module for diagnosis of acute myocardial infarction
Lee, J., Jung, J., Shin, D. H., & Kim, Y. T. (2012) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2012.6411371 · Cited by 7
Advances in microfluidic biofabrication technology for bone metastasis modeling
Khanmohammadi, M., Ahmadkhani, N., Volpi, M., Khederlou, K., Uppal, A., Hosseini, M., Zhang, Y. S., & Święszkowski, W. (2025) · Biofabrication · doi:10.1088/1758-5090/add95f · Cited by 8
Applications and Prospects of Microfluidic Chips in Orthopaedic Diseases
Yang, X., Tang, Q., Chen, L., Wu, K., & Shi, X. (2021) · Frontiers in Materials · doi:10.3389/fmats.2020.610558 · Cited by 8
“Besides, as shown in Figure 1B, Shin et al. (2011) designed a microfluidic chip with two main culture chambers.”
MethodMorita, M., Fujii, R., Ryuno, A., Morimoto, M., Inoko, A., Inoue, T., Ikenouchi, J., Atsuta, Y., Hayashi, Y., Teramoto, T., et al. (2025) · Developmental Biology · doi:10.1016/j.ydbio.2025.05.010 · Cited by 4
Microfluidics and Future of Cancer Diagnostics
Jamalian, S., Jafarnejad, M., & Aref, A. R. (2016) · Cancer drug discovery and develogment/Cancer drug discovery and development · doi:10.1007/978-3-319-45397-2_4 · Cited by 4
Study of diffusive- and convective-transport mediated microtumor growth in a controlled microchamber
Hsu, Y., Liu, W., Wu, T.-H., Lee, C. J.-T., Chen, Y.-H., & Li, P. (2019) · Biomedical Microdevices · doi:10.1007/s10544-018-0356-7 · Cited by 3
Microfluidics: A New Tool for Modeling Cancer-Immune
Boussommier-Calleja, I., Li, R., Chen, M. B., & Kamm, R. D. (2016) · Cited by 2
Lab-on-a-chip Systems for Cellomics—Materials and Technology
Kalinowska, D., Tokarska, K., Grabowska‐Jadach, I., Dybko, A., & Brzózka, Z. (2017) · Springer eBooks · doi:10.1007/978-3-319-70685-6_3 · Cited by 2
A Versatile Microfluidic Platform for Extravasation Studies Based on DNA Origami—Cell Interactions
García‐Chamé, M., Wadhwani, P., Pfeifer, J., Schepers, U., Niemeyer, C. M., & Domínguez, C. M. (2024) · Angewandte Chemie · doi:10.1002/ange.202318805 · Cited by 1
Cheng, J., Rock, E. C., Rao, M., Chen, H.-C., Ma, Y., Chang, K., & Chen, Y. (2025) · Cell Reports Methods · doi:10.1016/j.crmeth.2025.101117 · Cited by 1
“9, 15– 40 Microfluidic recreation of in vivo structural cues 16,21 to closely mimic physiological conditions.”
Garcia, A. R., & Brito, M. A. (2023) · Interdisciplinary cancer research · doi:10.1007/16833_2023_154 · Cited by 1
Advances in Micro-Bioreactor Design for Organ Cell Studies
Mandenius, C. (2018) · MDPI eBooks · doi:10.3390/books978-3-03897-232-7 · Cited by 1
Microfluidic studies on flow manipulation to assist metastasis research
Tran, D. Q. (2017) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/69578 · Cited by 1
Molecular Insights into Profilin Regulation and Its Role in Breast Cancer
Joy, M. (2017) · D-Scholarship@Pitt (University of Pittsburgh)
Microfluidic Platform for Human Diseases
Menon, N. V., Xue, P., & Kang, Y. (2014) · Springer eBooks · doi:10.1007/978-3-642-27758-0_941-9
Microfluidic Platform for Human Diseases
Menon, N. V., Xue, P., & Kang, Y. (2015) · Springer eBooks · doi:10.1007/978-1-4614-5491-5_941
Nichols, K. N., Snyder, J. R., Koppes, R. A., & Koppes, A. N. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.06.03.543561
A 3D Tumor-on-a-chip Platform to Identify Drugs that Block Breast Cancer Cell IntravasationPreprint
Perera, N. M., Coutinho, D., Morais, C., Faria, M. C., Neto, R., Roman, W., Gomes, E. R., Franco, C. A., Costa, L., Barata, D. B., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.03.19.712923
“This is an important advantage, since similar setups only focus on the quantification of intravasation via in situ imaging methods of fixed or living samples 16,20,24,26 .”
Ravi, P., Ghosh, S., Jaswandkar, S. V., Pashaki, P. V., Ha, D., Kim, J., Katti, D. R., & Katti, K. S. (2026) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.70069
Mierke, C. T. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-30048-6.00002-4
dos Santos, R. P. N., Roldan, D. C. B., Guven, M., Leite, L. C., Furlan, F. J. M., Silva, G., de Oliveira, V. A. P., Capriglione, C. D. S., da Silva, J. P., Pinto, J. C., et al. (2026) · Pharmaceutics · doi:10.3390/pharmaceutics18060679
“…such as 3D hydrodynamic flow focusing, intricate micromixer geometries, and controlled droplet generation have enabled the precise modulation of particle size, RNA loading, and surface charge, attributes that strongly influence cellular uptake, immune evasion, and biodistribution [85,86].”
Prospects of microfluidic analytical systems for biomedical applications
Singh, I., Sharma, N. K., Dakal, T. C., & Maurya, P. K. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36328-3.00001-2
Suresh, N. K., Christyraj, J. D. S., Rajagopal, T., & Baskar, H. M. (2026) · Molecular Biology Reports · doi:10.1007/s11033-026-12212-z
“The cell-based microfluidic chip integrates two distinct cham - bers that provide the analysis of altered epithelial cell adhesion molecules linked to intravasation and extravasation inside a single device, making it optimal for elucidating the metastatic behavior of cancer cells [80].”
Klyusko, I., Scardamaglia, M. G., Scalise, S., Aquila, I., Parrotta, E. I., Cuda, G., Caiazza, C., Palladino, R., Mallardo, M., Candeloro, P., et al. (2026) · Applied Sciences · doi:10.3390/app16146878
Metadata
- Authors
- Shin, M. K., Kim, S. K., & Jung, H.
- Affiliations
- Yonsei University (KR)
- Corresponding author
- Jung, Hyungil
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 22
- Pages
- 3880
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2164059729
- Cited by
- 94
- References
- 36
- Citations by year
- 2026: 7 · 2025: 5 · 2024: 5 · 2023: 4 · 2022: 10 · 2021: 3 · 2020: 10 · 2019: 7 · 2018: 7 · 2017: 7 · 2016: 6 · 2015: 6 · 2014: 9 · 2013: 7 · 2012: 1
- FWCI
- 3.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- metastasis, intravasation, extravasation, microfluidics, 3D cell culture, Matrigel, cell invasion, metalloproteinase inhibitors, tumor cell adhesion, shear stress, LoVo cells, SW480 cells, drug screening
- MeSH terms
- Cell Adhesion, Cell Separation, Cell Survival, Colonic Neoplasms, Humans, Neoplasm Invasiveness, Neoplasm Metastasis, Stress, Mechanical, Cell Adhesion Molecules, Gene Expression Regulation, Neoplastic, Systems Integration, Cell Line, Tumor, Microfluidic Analytical Techniques, Human Umbilical Vein Endothelial Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.