CoChat

Aluminium, iron and copper in human brain tissues donated to the medical research council's cognitive function and ageing study

House, Emily, Esiri, Margaret, Forster, Gill, Ince, Paul G, Exley, Christopher · 2012 · Metallomics
Cited by 122

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Aluminium, iron and copper are all implicated in the aetiology of neurodegenerative diseases including Alzheimer's disease. However, there are very few large cohort studies of the content of these metals in aged human brains. We have used microwave digestion and TH GFAAS to measure aluminium, iron and copper in the temporal, frontal, occipital and parietal lobes of 60 brains donated to the Cognitive Function and Ageing Study. Every precaution was taken to reduce contamination of samples and acid digests to a minimum. Actual contamination was estimated by preparing a large number of (170+) method blanks which were interspersed within the full set of 700+ tissue digests. Subtraction of method blank values (MBV) from tissue digest values resulted in metal contents in all tissues in the range, MBV to 33 μg g(-1) dry wt. for aluminium, 112 to 8305 μg g(-1) dry wt. for iron and MBV to 384 μg g(-1) dry wt. for copper. While the median aluminium content for all tissues was 1.02 μg g(-1) dry wt. it was informative that 41 brains out of 60 included at least one tissue with an aluminium content which could be considered as potentially pathological (> 3.50 μg g(-1) dry wt.). The median content for iron was 286.16 μg g(-1) dry wt. and overall tissue iron contents were generally high which possibly reflected increased brain iron in ageing and in neurodegenerative disease. The median content for copper was 17.41 μg g(-1) dry wt. and overall tissue copper contents were lower than expected for aged brains but they were commensurate with aged brains showing signs of neurodegenerative disease. In this study we have shown, in particular, the value of carrying out significant numbers of method blanks to identify unknown sources of contamination. When these values are subtracted from tissue digest values the absolute metal contents could be considered as conservative and yet they may still reflect aspects of ageing and neurodegenerative disease in individual brains.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c1mt00139f

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
House, E., Esiri, M., Forster, G., Ince, P. G., & Exley, C.
Venue
Metallomics
Published
2012
Volume
4
Issue
1
Pages
56-65
ISSN
  • 1756-5901 (ISSN-L)
  • 1756-591X
OpenAlex
W2105234293
Cited by
122
References
1
FWCI
7.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.