CoChat

Electric field standing wave artefacts in FTIR micro-spectroscopy of biological materials

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Abstract

FTIR absorption micro-spectroscopy is a widely used, powerful technique for analysing biological materials. In principle it is a straightforward linear absorption spectroscopy, but it can be affected by artefacts that complicate the interpretation of the data. In this article, artefacts produced by the electric-field standing-wave (EFSW) in micro-reflection-absorption (transflection) spectroscopy are investigated. An EFSW is present at reflective metallic surfaces due to the interference of incident and reflected light. The period of this standing wave is dependent on the wavelength of the radiation and can produce non-linear changes in absorbance with increasing sample thickness (non-Beer-Lambert like behaviour). A protein micro-structure was produced as a simple experimental model for a biological cell and used to evaluate the differences between FTIR spectra collected in transmission and transflection. By varying the thickness of the protein samples, the relationship between the absorbance and sample thickness in transflection was determined, and shown to be consistent with optical interference due to the EFSW coupled with internal reflection from the sample top surface. FTIR spectral image data from MCF 7 breast adenocarcinoma cells was then analysed to determine the severity of the EFSW artefact in data from a real sample. The results from these measurements confirmed that the EFSW artefact has a profound effect on transflection spectra, and in this case the main spectral variations were related to the sample thickness rather than any biochemical differences.

Overview

Integrity signals

Registry

Crossref · 10.1039/c2an15995c

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Research works printed but not linked: 1

  1. Filik, J. Phys.: Conf. Ser.

Cited by

See all 122

Metadata

Authors
Filik, J., Frogley, M. D., Pijanka, J. K., Wehbe, K., & Cinque, G.
Affiliations
Diamond Light Source (GB)
Corresponding author
Frogley, Mark D.
Venue
The Analyst
Published
2012
Volume
137
Issue
4
Pages
853
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W1995206944
Cited by
122
References
34
Citations by year
2026: 2 · 2025: 4 · 2024: 2 · 2023: 1 · 2022: 10 · 2021: 3 · 2020: 12 · 2019: 5 · 2018: 7 · 2017: 8 · 2016: 12 · 2015: 17 · 2014: 11 · 2013: 21 · 2012: 7
FWCI
8.20
Type
journal article
Language
en
Open access
closed
Locations
  • The Analyst (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Near-Field Optical Microscopy
Keywords
sample thickness dependence, optical interference, spectral image analysis
MeSH terms
Absorption, Breast Neoplasms, Female, Humans, Scattering, Radiation, Artifacts, Spectroscopy, Fourier Transform Infrared, Cell Line, Tumor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.