Electric field standing wave artefacts in FTIR micro-spectroscopy of biological materials
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
FTIR absorption micro-spectroscopy is a widely used, powerful technique for analysing biological materials. In principle it is a straightforward linear absorption spectroscopy, but it can be affected by artefacts that complicate the interpretation of the data. In this article, artefacts produced by the electric-field standing-wave (EFSW) in micro-reflection-absorption (transflection) spectroscopy are investigated. An EFSW is present at reflective metallic surfaces due to the interference of incident and reflected light. The period of this standing wave is dependent on the wavelength of the radiation and can produce non-linear changes in absorbance with increasing sample thickness (non-Beer-Lambert like behaviour). A protein micro-structure was produced as a simple experimental model for a biological cell and used to evaluate the differences between FTIR spectra collected in transmission and transflection. By varying the thickness of the protein samples, the relationship between the absorbance and sample thickness in transflection was determined, and shown to be consistent with optical interference due to the EFSW coupled with internal reflection from the sample top surface. FTIR spectral image data from MCF 7 breast adenocarcinoma cells was then analysed to determine the severity of the EFSW artefact in data from a real sample. The results from these measurements confirmed that the EFSW artefact has a profound effect on transflection spectra, and in this case the main spectral variations were related to the sample thickness rather than any biochemical differences.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Matplotlib: a 2D graphics environment
Hunter, J. D. (2007) · Computing in Science & Engineering · doi:10.1109/mcse.2007.55 · Cited by 39,249
WSXM: A software for scanning probe microscopy and a tool for nanotechnology
Horcas, I., Fernández, R., Gómez-Rodríguez, J. M., Colchero, J., Gómez-Herrero, J., & Baro, A. M. (2007) · Review of Scientific Instruments · doi:10.1063/1.2432410 · Cited by 7,738
Capillary flow as the cause of ring stains from dried liquid drops
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (1997) · Nature · doi:10.1038/39827 · Cited by 6,435
Python for scientific computing
Oliphant, T. E. (2007) · Computing in Science & Engineering · doi:10.1109/mcse.2007.58 · Cited by 3,303
The Use and Misuse of FTIR Spectroscopy in the Determination of Protein Structure
Jackson, M., & Mantsch, H. H. (1995) · Critical Reviews in Biochemistry and Molecular Biology · doi:10.3109/10409239509085140 · Cited by 2,037
Infrared Study of Adsorbed Molecules on Metal Surfaces by Reflection Techniques
Greenler, R. G. (1966) · The Journal of Chemical Physics · doi:10.1063/1.1726462 · Cited by 1,526
Hansen, W. N. (1968) · Journal of the Optical Society of America · doi:10.1364/josa.58.000380 · Cited by 729
Pulsed terahertz spectroscopy of DNA, bovine serum albumin and collagen between 0.1 and 2.0 THz
Markelz, A. G., Roitberg, A., & Heilweil, E. J. (2000) · Chemical Physics Letters · doi:10.1016/s0009-2614(00)00227-x · Cited by 705
Applications of ATR-FTIR spectroscopic imaging to biomedical samples
Kazarian, S. G., & Chan, K. L. A. (2006) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2006.02.011 · Cited by 379
Infrared Spectra of Monolayers on Metal Mirrors
Francis, S. A., & Ellison, A. H. (1959) · Journal of the Optical Society of America · doi:10.1364/josa.49.000131 · Cited by 343
Bassan, P., Byrne, H. J., Bonnier, F., Lee, J., Dumas, P., & Gardner, P. (2009) · The Analyst · doi:10.1039/b904808a · Cited by 316
Vibrational spectroscopy: a clinical tool for cancer diagnostics
Kendall, C., Isabelle, M., Bazant-Hegemark, F., Hutchings, J., Orr, L., Babrah, J., Baker, R., & Stone, N. (2009) · The Analyst · doi:10.1039/b822130h · Cited by 293
Spatial resolution in infrared microspectroscopic imaging of tissues
Lasch, P., & Naumann, D. (2006) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2006.06.008 · Cited by 257
The use of synchrotron infrared microspectroscopy in biological and biomedical investigations
Dumas, P., & Miller, L. (2003) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(03)00043-2 · Cited by 230
Biomedical applications of Raman and infrared spectroscopy to diagnose tissues
Krafft, C., & Sergo, V. (2006) · Journal of Spectroscopy · doi:10.1155/2006/738186 · Cited by 206
Towards a practical Fourier transform infrared chemical imaging protocol for cancer histopathology
Bhargava, R. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1511-9 · Cited by 184
Kohler, A., Sulé-Suso, J., Sockalingum, G. D., Tobin, M., Bahrami, F., Yang, Y., Pijanka, J., Dumas, P., Cotte, M., van Pittius, D. G., et al. (2008) · Applied Spectroscopy · doi:10.1366/000370208783759669 · Cited by 179
Self-citationStehende Lichtwellen und die Schwingungsrichtung polarisirten Lichtes
Wiener, O. (1890) · Annalen der Physik · doi:10.1002/andp.18902760603 · Cited by 160
Gazi, E., Dwyer, J., Lockyer, N. P., Miyan, J. A., Gardner, P., Hart, C. A., Brown, M. D., & Clarke, N. W. (2004) · Biopolymers · doi:10.1002/bip.20167 · Cited by 139
Drop coating deposition Raman spectroscopy of protein mixtures
Filik, J., & Stone, N. (2007) · The Analyst · doi:10.1039/b701541k · Cited by 123
Self-citationReflection contributions to the dispersion artefact in FTIR spectra of single biological cells
Bassan, P., Byrne, H. J., Lee, J., Bonnier, F., Clarke, C., Dumas, P., Gazi, E., Brown, M. D., Clarke, N. W., & Gardner, P. (2009) · The Analyst · doi:10.1039/b821349f · Cited by 123
Infrared micro-spectral imaging: distinction of tissue types in axillary lymph node histology
Bird, B., Miljković, M. D., Romeo, M., Smith, J. D., Stone, N., George, M. W., & Diem, M. (2008) · BMC Clinical Pathology · doi:10.1186/1472-6890-8-8 · Cited by 108
Analysis of human tear fluid by Raman spectroscopy
Filik, J., & Stone, N. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.04.036 · Cited by 108
Self-citationRomeo, M., Mohlenhoff, B., & Diem, M. (2006) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2006.04.009 · Cited by 91
Validation of the drop coating deposition Raman method for protein analysis
Ortiz, C., Zhang, D., Xie, Y., Ribbe, A. E., & Ben‐Amotz, D. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.03.025 · Cited by 91
Kopecký, V., & Baumruk, V. (2006) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2006.04.019 · Cited by 55
Pijanka, J. K., Kohler, A., Yang, Y., Dumas, P., Chio-Srichan, S., Manfait, M., Sockalingum, G. D., & Sulé-Suso, J. (2009) · The Analyst · doi:10.1039/b821112d · Cited by 55
Self-citationLee, J., Gazi, E., Dwyer, J., Brown, M. D., Clarke, N. W., Nicholson, J. M., & Gardner, P. (2007) · The Analyst · doi:10.1039/b702064c · Cited by 54
Multimode InfraRed Imaging and Microspectroscopy (MIRIAM) Beamline at Diamond
Cinque, G., Frogley, M. D., Wehbe, K., Filik, J., & Pijanka, J. K. (2011) · Synchrotron Radiation News · doi:10.1080/08940886.2011.618093 · Cited by 53
Self-citationStochastic Computational Fluid Mechanics
Lin, G., Wan, X., Su, C. H., & Karniadakis, G. E. (2007) · Computing in Science & Engineering · doi:10.1109/mcse.2007.38 · Cited by 36
Cytology by infrared micro-spectroscopy: Automatic distinction of cell types in urinary cytology
Bird, B., Romeo, M., Diem, M., Bedrossian, K., Laver, N., & Naber, S. P. (2008) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2008.03.006 · Cited by 36
A Study of Electric Field Standing Waves on Reflection Microspectroscopy of Polystyrene Particles
Brooke, H., Bronk, B. V., McCutcheon, J. N., Morgan, S. L., & Myrick, M. L. (2009) · Applied Spectroscopy · doi:10.1366/000370209789806902 · Cited by 26
Brooke, H., Perkins, D. L., Setlow, B., Setlow, P., Bronk, B. V., & Myrick, M. L. (2008) · Applied Spectroscopy · doi:10.1366/000370208785284358 · Cited by 14
Considerations of optical anisotropy in the simulation of reflection absorption infrared spectra
Pilling, M. J., Gardner, P., & Vent, S. L. (2005) · Surface Science · doi:10.1016/j.susc.2005.03.002 · Cited by 5
Research works printed but not linked: 1
- Filik, J. Phys.: Conf. Ser.
Cited by
Using Fourier transform IR spectroscopy to analyze biological materials
Baker, M. J., Trevisan, J., Bassan, P., Bhargava, R., Butler, H. J., Dorling, K. M., Fielden, P. R., Fogarty, S. W., Fullwood, N. J., Heys, K. A., et al. (2014) · Nature Protocols · doi:10.1038/nprot.2014.110 · Cited by 1,958
The Bouguer-Beer-Lambert Law: Shining Light on the Obscure
Mayerhöfer, T. G., Pahlow, S., & Popp, J. (2020) · ChemPhysChem · doi:10.1002/cphc.202000464 · Cited by 671
ATR-FTIR spectroscopic imaging: recent advances and applications to biological systems
Kazarian, S. G., & Chan, K. L. A. (2013) · The Analyst · doi:10.1039/c3an36865c · Cited by 414
Developing and understanding biofluid vibrational spectroscopy: a critical review
Baker, M. J., Hussain, S. R., Lovergne, L., Untereiner, V., Hughes, C., Lukaszewski, R. A., Thiéfin, G., & Sockalingum, G. D. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00585j · Cited by 358
Infrared Spectroscopic Imaging: The Next Generation
Bhargava, R. (2012) · Applied Spectroscopy · doi:10.1366/12-06801 · Cited by 280
Metadata
- Authors
- Filik, J., Frogley, M. D., Pijanka, J. K., Wehbe, K., & Cinque, G.
- Affiliations
- Diamond Light Source (GB)
- Corresponding author
- Frogley, Mark D.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 137
- Issue
- 4
- Pages
- 853
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W1995206944
- Cited by
- 122
- References
- 34
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 2 · 2023: 1 · 2022: 10 · 2021: 3 · 2020: 12 · 2019: 5 · 2018: 7 · 2017: 8 · 2016: 12 · 2015: 17 · 2014: 11 · 2013: 21 · 2012: 7
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Analyst (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Near-Field Optical Microscopy
- Keywords
- sample thickness dependence, optical interference, spectral image analysis
- MeSH terms
- Absorption, Breast Neoplasms, Female, Humans, Scattering, Radiation, Artifacts, Spectroscopy, Fourier Transform Infrared, Cell Line, Tumor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.