Electric field standing wave artefacts in FTIR micro-spectroscopy of biological materials
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
FTIR absorption micro-spectroscopy is a widely used, powerful technique for analysing biological materials. In principle it is a straightforward linear absorption spectroscopy, but it can be affected by artefacts that complicate the interpretation of the data. In this article, artefacts produced by the electric-field standing-wave (EFSW) in micro-reflection-absorption (transflection) spectroscopy are investigated. An EFSW is present at reflective metallic surfaces due to the interference of incident and reflected light. The period of this standing wave is dependent on the wavelength of the radiation and can produce non-linear changes in absorbance with increasing sample thickness (non-Beer-Lambert like behaviour). A protein micro-structure was produced as a simple experimental model for a biological cell and used to evaluate the differences between FTIR spectra collected in transmission and transflection. By varying the thickness of the protein samples, the relationship between the absorbance and sample thickness in transflection was determined, and shown to be consistent with optical interference due to the EFSW coupled with internal reflection from the sample top surface. FTIR spectral image data from MCF 7 breast adenocarcinoma cells was then analysed to determine the severity of the EFSW artefact in data from a real sample. The results from these measurements confirmed that the EFSW artefact has a profound effect on transflection spectra, and in this case the main spectral variations were related to the sample thickness rather than any biochemical differences.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Matplotlib: a 2D graphics environment
Hunter, J. D. (2007) · Computing in Science & Engineering · doi:10.1109/mcse.2007.55 · Cited by 39,249
WSXM: A software for scanning probe microscopy and a tool for nanotechnology
Horcas, I., Fernández, R., Gómez-Rodríguez, J. M., Colchero, J., Gómez-Herrero, J., & Baro, A. M. (2007) · Review of Scientific Instruments · doi:10.1063/1.2432410 · Cited by 7,738
Capillary flow as the cause of ring stains from dried liquid drops
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (1997) · Nature · doi:10.1038/39827 · Cited by 6,435
Python for scientific computing
Oliphant, T. E. (2007) · Computing in Science & Engineering · doi:10.1109/mcse.2007.58 · Cited by 3,303
The Use and Misuse of FTIR Spectroscopy in the Determination of Protein Structure
Jackson, M., & Mantsch, H. H. (1995) · Critical Reviews in Biochemistry and Molecular Biology · doi:10.3109/10409239509085140 · Cited by 2,037
Infrared Study of Adsorbed Molecules on Metal Surfaces by Reflection Techniques
Greenler, R. G. (1966) · The Journal of Chemical Physics · doi:10.1063/1.1726462 · Cited by 1,526
Hansen, W. N. (1968) · Journal of the Optical Society of America · doi:10.1364/josa.58.000380 · Cited by 729
Pulsed terahertz spectroscopy of DNA, bovine serum albumin and collagen between 0.1 and 2.0 THz
Markelz, A. G., Roitberg, A., & Heilweil, E. J. (2000) · Chemical Physics Letters · doi:10.1016/s0009-2614(00)00227-x · Cited by 705
Applications of ATR-FTIR spectroscopic imaging to biomedical samples
Kazarian, S. G., & Chan, K. L. A. (2006) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2006.02.011 · Cited by 379
Infrared Spectra of Monolayers on Metal Mirrors
Francis, S. A., & Ellison, A. H. (1959) · Journal of the Optical Society of America · doi:10.1364/josa.49.000131 · Cited by 343
Research works printed but not linked: 1
- Filik, J. Phys.: Conf. Ser.
Cited by
Using Fourier transform IR spectroscopy to analyze biological materials
Baker, M. J., Trevisan, J., Bassan, P., Bhargava, R., Butler, H. J., Dorling, K. M., Fielden, P. R., Fogarty, S. W., Fullwood, N. J., Heys, K. A., et al. (2014) · Nature Protocols · doi:10.1038/nprot.2014.110 · Cited by 1,958
The Bouguer-Beer-Lambert Law: Shining Light on the Obscure
Mayerhöfer, T. G., Pahlow, S., & Popp, J. (2020) · ChemPhysChem · doi:10.1002/cphc.202000464 · Cited by 671
ATR-FTIR spectroscopic imaging: recent advances and applications to biological systems
Kazarian, S. G., & Chan, K. L. A. (2013) · The Analyst · doi:10.1039/c3an36865c · Cited by 414
Developing and understanding biofluid vibrational spectroscopy: a critical review
Baker, M. J., Hussain, S. R., Lovergne, L., Untereiner, V., Hughes, C., Lukaszewski, R. A., Thiéfin, G., & Sockalingum, G. D. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00585j · Cited by 358
Infrared Spectroscopic Imaging: The Next Generation
Bhargava, R. (2012) · Applied Spectroscopy · doi:10.1366/12-06801 · Cited by 280
Progress in infrared spectroscopy as an efficient tool for predicting protein secondary structure
Yang, S., Zhang, Q., Yang, H., Shi, H., Dong, A., Wang, L., & Yu, S. (2022) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.02.104 · Cited by 246
Clinical applications of infrared and Raman spectroscopy: state of play and future challenges
Baker, M. J., Byrne, H. J., Chalmers, J., Gardner, P., Goodacre, R., Henderson, A., Kazarian, S. G., Martin, F. L., Moger, J., Stone, N., et al. (2018) · The Analyst · doi:10.1039/c7an01871a · Cited by 230
Molecular pathology via IR and Raman spectral imaging
Diem, M., Mazur, A., Lenau, K., Schubert, J., Bird, B., Miljković, M., Krafft, C., & Popp, J. (2013) · Journal of Biophotonics · doi:10.1002/jbio.201300131 · Cited by 209
Fundamental developments in infrared spectroscopic imaging for biomedical applications
Pilling, M., & Gardner, P. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00846h · Cited by 165
Li, C., Butler, H. J., Martin‐Hirsch, P. L., & Martin, F. L. (2015) · Analytical Methods · doi:10.1039/c5ay02638e · Cited by 149
Kumar, S., Verma, T., Mukherjee, R., Ariese, F., Somasundaram, K., & Umapathy, S. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00540j · Cited by 145
Mid-IR hyperspectral imaging for label-free histopathology and cytology
Hermes, M., Morrish, R. B., Huot, L., Meng, L., Junaid, S., Tomko, J., Lloyd, G. R., Masselink, W. T., Tidemand‐Lichtenberg, P., Pedersen, C., et al. (2017) · Journal of Optics · doi:10.1088/2040-8986/aaa36b · Cited by 143
Bassan, P., Lee, J., Sachdeva, A., Pissardini, J., Dorling, K. M., Fletcher, J. S., Henderson, A., & Gardner, P. (2013) · The Analyst · doi:10.1039/c2an36090j · Cited by 130
Infrared Spectroscopic Imaging Advances as an Analytical Technology for Biomedical Sciences
Wróbel, T. P., & Bhargava, R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05330 · Cited by 137
High-Definition Infrared Spectroscopic Imaging
Reddy, R. K., Walsh, M. J., Schulmerich, M. V., Carney, P. S., & Bhargava, R. (2013) · Applied Spectroscopy · doi:10.1366/11-06568 · Cited by 123
“While we focus here only on the capabilities of the microscope, there are other theoretical approaches dealing comprehensively with the effects of optical properties of the sample; size and shape of domains;(16) geometry of acquisition; and microscopy optics on both spectral distortions(17,18) and image formation.(19,…”
Vibrational spectroscopic methods for cytology and cellular research
Clemens, G., Hands, J. R., Dorling, K. M., & Baker, M. J. (2014) · The Analyst · doi:10.1039/c4an00636d · Cited by 124
Vaccari, L., Birarda, G., Businaro, L., Pacor, S., & Grenci, G. (2012) · Analytical Chemistry · doi:10.1021/ac300313x · Cited by 89
Assessing the challenges of Fourier transform infrared spectroscopic analysis of blood serum
Hughes, C. S., Brown, M. D., Clemens, G., Henderson, A., Monjardez, G., Clarke, N. W., & Gardner, P. (2014) · Journal of Biophotonics · doi:10.1002/jbio.201300167 · Cited by 79
Vibrational spectroscopy for cancer diagnostics
Old, O. J., Fullwood, L. M., Scott, R. A., Lloyd, G. R., Almond, M., Shepherd, N. A., Stone, N., Barr, H., & Kendall, C. A. (2014) · Analytical Methods · doi:10.1039/c3ay42235f · Cited by 81
Louvet, L., Bazin, D. C., Büchel, J., Steppan, S., Passlick‐Deetjen, J., & Massy, Z. A. (2015) · PLoS ONE · doi:10.1371/journal.pone.0115342 · Cited by 76
“More precisely, biological objects like mammalian cells could cause slight peak shifts or deviations compared to what is theoretically expected [33, 34, 35].”
The effect of optical substrates on micro-FTIR analysis of single mammalian cells
Wehbe, K., Filik, J., Frogley, M. D., & Cinque, G. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6521-6 · Cited by 67
“This pattern of the loadings vector, which effectively shows opposite signal sign respectively at high and low wavenumber, has been observed before in PCA analysis of cell R data, and it has been explained as an artifact due to an electric field standing wave [22, 23].”
BackgroundSelf-citationVibrational spectroscopy of articular cartilage
Rieppo, L., Töyräs, J., & Saarakkala, S. S. (2016) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1226182 · Cited by 76
“observed in transflectance measurements (13).”
FTIR Imaging of Tissues: Techniques and Methods of Analysis
Małek, K., Wood, B. R., & Bambery, K. R. (2013) · Challenges and advances in computational chemistry and physics · doi:10.1007/978-94-007-7832-0_15 · Cited by 73
Bassan, P., Mellor, J., Shapiro, J., Williams, K. J., Lisanti, M. P., & Gardner, P. (2014) · Analytical Chemistry · doi:10.1021/ac403412n · Cited by 67
Infrared Spectroscopy of Blood
Kochan, K., Bedolla, D. E., Pérez-Guaita, D., Adegoke, J. A., Veettil, T. C. P., Martin, M., Roy, S., Pebotuwa, S., Heraud, P., & Wood, B. R. (2020) · Applied Spectroscopy · doi:10.1177/0003702820985856 · Cited by 67
Chen, L., Holman, H. N., Hao, Z., Bechtel, H. A., Martin, M. C., Wu, C., & Chu, S. (2012) · Analytical Chemistry · doi:10.1021/ac300308x · Cited by 61
Pilling, M. J., Henderson, A., Bird, B., Brown, M. D., Clarke, N. W., & Gardner, P. (2016) · Faraday Discussions · doi:10.1039/c5fd00176e · Cited by 66
Lima, C. A., Goulart, V. P., Côrrea, L., Pereira, T. M., & Zezéll, D. M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16046621 · Cited by 64
“In transflection, the low-emissivity slides commonly used as reflector substrates contribute to formation of a standing wave perpendicular to sample surface that leads to spectral changes not related to the biochemistry of sample [11–13].”
BackgroundFullwood, L. M., Griffiths, D., Ashton, K. M., Dawson, T., Lea, R. W., Davis, C., Bonnier, F., Byrne, H. J., & Baker, M. J. (2013) · The Analyst · doi:10.1039/c3an01832f · Cited by 58
Single-cell analysis using Fourier transform infrared microspectroscopy
Doherty, J., Cinque, G., & Gardner, P. (2016) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1250214 · Cited by 64
Self-citationLee, B.-J., Zhou, Y., Lee, J. S., Shin, B. K., Seo, J., Lee, D., Kim, Y.-S., & Choi, H. (2018) · PLoS ONE · doi:10.1371/journal.pone.0196315 · Cited by 57
Mayerhöfer, T. G., Pahlow, S., Hübner, U., & Popp, J. (2018) · The Analyst · doi:10.1039/c8an00526e · Cited by 56
The electric field standing wave effect in infrared transflection spectroscopy
Mayerhöfer, T. G., & Popp, J. (2018) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2017.10.033 · Cited by 55
Spectral cytopathology: new aspects of data collection, manipulation and confounding effects
Miljković, M. D., Bird, B., Lenau, K., Mazur, A. I., & Diem, M. (2013) · The Analyst · doi:10.1039/c3an00185g · Cited by 58
Butler, H. J., Cameron, J. M., Jenkins, C. A., Hithell, G., Rutherford, S. H., Hunt, N. T., & Baker, M. J. (2019) · Clinical Spectroscopy · doi:10.1016/j.clispe.2020.100003 · Cited by 52
“employment of reflective substrates [21].”
Loutherback, K., Birarda, G., Chen, L., & Holman, H. N. (2016) · Protein and Peptide Letters · doi:10.2174/0929866523666160106154035 · Cited by 57
“While there remains concerns about electric field standing wave effects during transflection measurement [104], this material would allow cheap, rapid device fabrication and the inclusion of multilayer structures with a large suite of features including valves and mixers [105].”
Pilling, M. J., Henderson, A., Shanks, J. H., Brown, M. D., Clarke, N. W., & Gardner, P. (2016) · The Analyst · doi:10.1039/c6an02224c · Cited by 51
Lee, B.-J., Kim, H.-Y., Lim, S. R., Huang, L., & Choi, H. (2017) · PLoS ONE · doi:10.1371/journal.pone.0186664 · Cited by 40
The Electric Field Standing Wave Effect in Infrared Transmission Spectroscopy
Mayerhöfer, T. G., Mutschke, H., & Popp, J. (2017) · ChemPhysChem · doi:10.1002/cphc.201700688 · Cited by 37
Clemens, G., Flower, K. R., Henderson, A. P., Whiting, A., Przyborski, S. A., Jiménez-Hernández, M. E., Ball, F., Bassan, P., Cinque, G., & Gardner, P. (2013) · Molecular BioSystems · doi:10.1039/c3mb25505k · Cited by 36
Self-citationErrico, S., Moggio, M., Diano, N., Portaccio, M., & Lepore, M. A. (2022) · Biotechnology and Applied Biochemistry · doi:10.1002/bab.2411 · Cited by 42
Wrobel, T. P., Wajnchold, B., Byrne, H. J., & Baranska, M. (2013) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2013.09.008 · Cited by 35
Comparison of FTIR transmission and transfection substrates for canine liver cancer detection
Kochan, K., Heraud, P., Kiupel, M., Yuzbasiyan‐Gurkan, V., McNaughton, D., Barańśka, M., & Wood, B. R. (2014) · The Analyst · doi:10.1039/c4an01901f · Cited by 35
Staniszewska-Slezak, E., Rygula, A., Malek, K., & Baranska, M. (2015) · The Analyst · doi:10.1039/c4an01842g · Cited by 34
Ghosh, A., Chaudhuri, D., Adhikary, S., Chatterjee, K., Chowdhury, A. R., Das, A. K., & Barui, A. (2022) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2022.104548 · Cited by 37
Comparison of transmission and transflectance mode FTIR imaging of biological tissue
Pilling, M. J., Bassan, P., & Gardner, P. (2015) · The Analyst · doi:10.1039/c4an01975j · Cited by 36
Hackett, M. J., Aitken, J. B., El‐Assaad, F., McQuillan, J. A., Carter, E. A., Ball, H. J., Tobin, M. J., Paterson, D., de Jonge, M. D., Siegele, R., et al. (2015) · Science Advances · doi:10.1126/sciadv.1500911 · Cited by 37
Sackett, O., Petrou, K., Reedy, B. J., Hill, R., Doblin, M. A., Beardall, J., Ralph, P. J., & Heraud, P. (2015) · The ISME Journal · doi:10.1038/ismej.2015.123 · Cited by 40
“This method has been shown to result in cellular monolayers with homogenous thickness (Cao et al., 2013; Heraud and Wood, 2013) and therefore minimize issues related to the previously reported electric field standing wave effect (Bassan et al., 2009, 2013; Filik et al., 2012).”
MethodLoutherback, K., Chen, L., & Holman, H. N. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00524 · Cited by 31
Wiens, R., Findlay, C. R. J., Baldwin, S. G., Kreplak, L., Lee, J. M., Veres, S. P., & Gough, K. M. (2016) · Faraday Discussions · doi:10.1039/c5fd00168d · Cited by 33
Alteration of Asian lacquer: in-depth insight using a physico-chemical multiscale approach
Hô, A. L., Duhamel, C., Daher, C., Bellot‐Gurlet, L., Paris, C., Regert, M., Sablier, M., André, G., Desroches, J.-P., & Dumas, P. (2013) · The Analyst · doi:10.1039/c3an00608e · Cited by 30
Pérez-Guaita, D., Heraud, P., Marzec, K. M., de la Guárdia, M., Kiupel, M., & Wood, B. R. (2015) · The Analyst · doi:10.1039/c4an02034k · Cited by 30
Bassan, P., Sachdeva, A., Lee, J., & Gardner, P. (2013) · The Analyst · doi:10.1039/c3an00363a · Cited by 31
Vibrational spectroscopic analysis and quantification of proteins in human blood plasma and serum
Cameron, J. M., Bruno, C., Parachalil, D. R., Baker, M. J., Bonnier, F., Butler, H. J., & Byrne, H. J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818610-7.00010-4 · Cited by 35
Whole organ cross-section chemical imaging using label-free mega-mosaic FTIR microscopy
Bassan, P., Sachdeva, A., Shanks, J. H., Brown, M. D., Clarke, N. W., & Gardner, P. (2013) · The Analyst · doi:10.1039/c3an01674a · Cited by 28
Mattson, E. C., Aboualizadeh, E., Barabas, M. E., Stucky, C. L., & Hirschmugl, C. J. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms141122753 · Cited by 29
“this directly impacts the intensity profiles that are detected [43,44].”
BackgroundWróbel, T. P., Mateuszuk, Ł., Kostogrys, R. B., Chłopicki, S., & Barańśka, M. (2013) · The Analyst · doi:10.1039/c3an01050c · Cited by 27
Tiwari, S., & Bhargava, R. (2015) · PubMed Central · Cited by 36
Chwiej, J. G., Dróźdż, A., Janeczko, K. J., Kutorasinska, J., Matusiak, K., Figiel, H., Dumas, P., Sandt, C., & Setkowicz, Z. (2015) · The Analyst · doi:10.1039/c4an01857e · Cited by 27
Determination of cell cycle phases in live B16 melanoma cells using IRMS
Bedolla, D. E., Kenig, S., Mitri, E., Ferraris, P. C., Marcello, A., Grenci, G., & Vaccari, L. (2013) · The Analyst · doi:10.1039/c3an00318c · Cited by 27
The Convergence of FTIR and EVs: Emergence Strategy for Non-Invasive Cancer Markers Discovery
Wong, L.-W., Mak, S.-H., Goh, B. H., & Lee, W.-L. (2022) · Diagnostics · doi:10.3390/diagnostics13010022 · Cited by 27
“[108] showed that variations in the thickness of bovine serum albumin (BSA) films, ranging from 200 to 1200 nm, gave rise to a different extent of the EFSW artifact, which exerted a significant effect on the transflection spectra by having a non-linear relationship with the IR wavelength.”
BackgroundInvestigation of intervertebral disc degeneration using multivariate FTIR spectroscopic imaging
Mader, K. T., Peeters, M., Detiger, S. E. L., Helder, M. N., Smit, T. H., Maitre, C. L. L., & Sammon, C. (2016) · Faraday Discussions · doi:10.1039/c5fd00160a · Cited by 26
Hackett, M. J., Lee, J., El‐Assaad, F., McQuillan, J. A., Carter, E. A., Grau, G. E., Hunt, N. H., & Lay, P. A. (2012) · ACS Chemical Neuroscience · doi:10.1021/cn300093g · Cited by 26
Polarised infrared microspectroscopy of edge-oriented graphene oxide papers
Frogley, M. D., Wang, C., Cinque, G., & Barber, A. H. (2014) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2014.07.005 · Cited by 22
Self-citationPurandare, N. C., Trevisan, J., Patel, I. I., Gajjar, K. B., Mitchell, A. L., Theophilou, G., Valasoulis, G., Martin, M., Bünau, G. V., Kyrgiou, M., et al. (2013) · Bioanalysis · doi:10.4155/bio.13.233 · Cited by 22
Tiwari, S., Reddy, V., Bhargava, R., & Raman, J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0125183 · Cited by 22
Progress in Fourier Transform Infrared Spectroscopic Imaging Applied to Venereal Cancer Diagnosis
Wood, B. R., Kiupel, M., & McNaughton, D. (2013) · Veterinary Pathology · doi:10.1177/0300985813501340 · Cited by 22
“nonlinear change in absorbance with sample thickness.(7,27) This can be overcome to some degree in tissue, where the refractive index is essentially the same across the specimen, by having even tissue section depths and by using second-derivative spectra, which are sensitive to changes in band profiles and not solely…”
BackgroundDeVetter, B. M., Kenkel, S., Mittal, S., Bhargava, R., & Wróbel, T. P. (2016) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2016.09.001 · Cited by 22
Infrared imaging in histopathology: Is a unified approach possible?
Goormaghtigh, E. (2016) · Biomedical Spectroscopy and Imaging · doi:10.3233/bsi-160151 · Cited by 22
Lee, J. (2017) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2017.03.007 · Cited by 20
Discrimination of skin cancer cells using Fourier transform infrared spectroscopy
Peñaranda, F., Naranjo, V., Lloyd, G. R., Kastl, L., Kemper, B., Schnekenburger, J., Nallala, J., & Stone, N. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.06.023 · Cited by 22
Fourier transform infrared applications to investigate induced biochemical changes in liver
Liyanage, S., & Abidi, N. (2019) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2019.1692307 · Cited by 19
Cao, J., Ng, E. S., McNaughton, D., Stanley, E. G., Elefanty, A. G., Tobin, M. J., & Heraud, P. (2013) · The Analyst · doi:10.1039/c3an00321c · Cited by 18
Towards a quantum cascade laser-based implant for the continuous monitoring of glucose
Isensee, K., Müller, N., Pucci, A., & Petrich, W. H. (2018) · The Analyst · doi:10.1039/c8an01382a · Cited by 18
Hanifi, A., McGoverin, C., Ou, Y.-T., Safadi, F. F., Spencer, R. G. S., & Pleshko, N. L. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.03.053 · Cited by 17
Majzner, K., Wróbel, T. P., Fedorowicz, A., Chłopicki, S., & Barańśka, M. (2013) · The Analyst · doi:10.1039/c3an00455d · Cited by 19
Rosi, F., Legan, L., Miliani, C., & Ropret, P. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0260-7 · Cited by 19
“Moreover, also in a pure transflection regime, spectral variations due to the reflection from a metallic-like surface generating electric-field standing waves (EFSWs) are expected [8, 12].”
BackgroundRicciardi, V., Portaccio, M., Perna, G., Lasalvia, M., Capozzi, V., Cammarata, F. P., Pisciotta, P., Petringa, G., Delfino, I., Manti, L., et al. (2021) · Applied Sciences · doi:10.3390/app11020540 · Cited by 14
Insights on diagnosis of oral cavity pathologies by infrared spectroscopy: A review
Giorgini, E., Balercia, P., Conti, C., Ferraris, P. C., Sabbatini, S., Rubini, C., & Tosi, G. (2013) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2013.08.007 · Cited by 15
Tonoue, R., Katsura, M., Hamamoto, M., Bessho, H., & Nakashima, S. (2014) · Applied Spectroscopy · doi:10.1366/13-07063 · Cited by 15
Vibrational Biospectroscopy: An Alternative Approach to Endometrial Cancer Diagnosis and Screening
Schiemer, R., Furniss, D., Phang, S., Seddon, A. B., Atiomo, W., & Gajjar, K. B. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23094859 · Cited by 16
“Transflection was shown to introduce spectral artefacts and so has lost favour [91,92].”
BackgroundElectric field standing wave effects in internal reflection and ATR spectroscopy
Mayerhöfer, T. G., & Popp, J. (2017) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2017.10.007 · Cited by 15
Wongwattanakul, M., Hahnvajanawong, C., Tippayawat, P., Chio‐Srichan, S., Leelayuwat, C., Limpaiboon, T., Jearanaikoon, P., & Heraud, P. (2016) · Journal of Biophotonics · doi:10.1002/jbio.201500253 · Cited by 13
Liberda, D., Hermes, M., Kozioł, P., Stone, N., & Wróbel, T. P. (2020) · Journal of Biophotonics · doi:10.1002/jbio.202000122 · Cited by 13
Khambatta, K., Hollings, A. L., Sauzier, G., Sanglard, L. V. P., Klein, A. R., Tobin, M. J., Vongsvivut, J. P., Gibberd, M., Payne, A. D., Naim, F., et al. (2021) · Advanced Science · doi:10.1002/advs.202101902 · Cited by 13
Shakya, B. R., Teppo, H., & Rieppo, L. (2022) · The Analyst · doi:10.1039/d1an01999f · Cited by 13
Bosio, G. N., Parisi, J. M., Einschlag, F. S. G., & Mártire, D. O. (2018) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2018.01.027 · Cited by 10
“Corrections due to standing wave effect [24] were not performed because we focused on band shifts that should not be affected by these effects.”
BackgroundWróbel, T. P., Liberda, D., Kozioł, P., Paluszkiewicz, C., & Kwiatek, W. M. (2020) · Infrared Physics & Technology · doi:10.1016/j.infrared.2020.103291 · Cited by 9
Veettil, T. C. P., Kochan, K., Edler, K. J., Bank, P. D., Heraud, P., & Wood, B. R. (2021) · Applied Spectroscopy · doi:10.1177/00037028211012722 · Cited by 8
Improved tissue preparation for multimodal vibrational imaging of biological tissues
Gassner, C., Adegoke, J. A., Patel, S. K., Sharma, V. J., Kochan, K., Burrell, L. M., Raman, J., & Wood, B. R. (2022) · Clinical Spectroscopy · doi:10.1016/j.clispe.2022.100021 · Cited by 8
Morphological analysis of vibrational hyperspectral imaging data
Filik, J., Rutter, A. V., Sulé‐Suso, J., & Cinque, G. (2012) · The Analyst · doi:10.1039/c2an35914f · Cited by 7
Self-citationMonitoring the Progress and Healing Status of Burn Wounds Using Infrared Spectroscopy
de Castro, P. A. A., Lima, C. A., Morais, M., Zorn, T. M. T., & Zezéll, D. M. (2020) · Applied Spectroscopy · doi:10.1177/0003702820919446 · Cited by 7
Vibrational imaging of proteins: changes in the tissues and cells in the lifestyle disease studies
Majzner, K., Czamara, K., Pacia, M. Z., Dybaś, J., Bik, E., Chrabąszcz, K., Wiercigroch, E., Borek-Dorosz, A., Wislocka, A., Marzec, K. M., et al. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818610-7.00007-4 · Cited by 7
Tiwari, S., Zong, X., Holton, S. E., Prasanth, K. V., & Bhargava, R. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2082347 · Cited by 6
Multimodal imaging of tissue using the combination of vibrational spectroscopy and mass spectrometry
Zetterström, A., Lockyer, N. P., & Gardner, P. (2025) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2025.2488469 · Cited by 5
Liberda, D., Kozioł, P., Raczkowska, M. K., Kwiatek, W. M., & Wróbel, T. P. (2020) · The Analyst · doi:10.1039/d0an01565b · Cited by 6
Molecular Pathology via Infrared and Raman Spectral Imaging 1)
Diem, M., Mazur, A. I., Lenau, K., Schubert, J., Fore, J. L., Bird, B., Miljković, M. D., Krafft, C., & Popp, J. (2014) · Wiley eBooks · doi:10.1002/9783527681921.ch3 · Cited by 5
Zhao, X., Shao, J., Tian, Y., Gui, Z., Tang, P. T. P., Li, Q., Wang, Z., & Wu, C. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c06805 · Cited by 4
Sun, Y., Zhao, H., Shen, Y., & Wang, P. (2025) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2025.109077 · Cited by 6
Tang, Y.-Q.-N., Li, L., Lin, T., Lin, L., Li, Y., & Xia, B. (2022) · Molecules · doi:10.3390/molecules27144640 · Cited by 4
“However, the obtained FT-IR spectra can be affected by the characteristics of samples in thickness and particle size [12,13], so the acquired raw data should be normalized.”
Background
Metadata
- Authors
- Filik, J., Frogley, M. D., Pijanka, J. K., Wehbe, K., & Cinque, G.
- Affiliations
- Diamond Light Source (GB)
- Corresponding author
- Frogley, Mark D.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 137
- Issue
- 4
- Pages
- 853
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W1995206944
- Cited by
- 122
- References
- 34
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 2 · 2023: 1 · 2022: 10 · 2021: 3 · 2020: 12 · 2019: 5 · 2018: 7 · 2017: 8 · 2016: 12 · 2015: 17 · 2014: 11 · 2013: 21 · 2012: 7
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Analyst (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Near-Field Optical Microscopy
- Keywords
- sample thickness dependence, optical interference, spectral image analysis
- MeSH terms
- Absorption, Breast Neoplasms, Female, Humans, Scattering, Radiation, Artifacts, Spectroscopy, Fourier Transform Infrared, Cell Line, Tumor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.