The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Catalytic interconversion between hydrogen and formic acid at ambient temperature and pressure
Abstract
Interconversion between hydrogen and formic acid in water at ambient temperature and pressure has been made possible by using a [C,N] cyclometalated organoiridium complex, [IrIII(Cp*)(4-(1H-pyrazol-1-yl-κN2)benzoic acid-κC3)(H2O)]2SO4 [1]2·SO4, as an efficient catalyst for both directions depending on pH. Hydrogenation of carbon dioxide by hydrogen occurs in the presence of a catalytic amount of 1 under an atmospheric pressure of H2 and CO2 in weakly basic water (pH 7.5) at room temperature, whereas formic acid efficiently decomposes to afford H2 and CO2 in the presence of 1 in acidic water (pH 2.8).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Efficient Dehydrogenation of Formic Acid Using an Iron Catalyst
Boddien, A., Mellmann, D., Gärtner, F., Jackstell, R., Junge, H., Dyson, P. J., Laurenczy, G., Ludwig, R., & Beller, M. (2011) · Science · doi:10.1126/science.1206613 · Cited by 832
Cited by
Artz, J., Müller, T. E., Thenert, K., Kleinekorte, J., Meys, R., Sternberg, A., Bardow, A., & Leitner, W. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00435 · Cited by 2,436
Frontiers, Opportunities, and Challenges in Biochemical and Chemical Catalysis of CO 2 Fixation
Appel, A. M., Bercaw, J. E., Bocarsly, A. B., Dobbek, H., DuBois, D. L., Dupuis, M., Ferry, J. G., Fujita, E., Hille, R., Kenis, P. J. A., et al. (2013) · Chemical Reviews · doi:10.1021/cr300463y · Cited by 2,193
Wang, W.-H., Himeda, Y., Muckerman, J. T., Manbeck, G. F., & Fujita, E. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00197 · Cited by 1,507
Centi, G., Quadrelli, E. A., & Perathoner, S. (2013) · Energy & Environmental Science · doi:10.1039/c3ee00056g · Cited by 1,257
Homogeneous Catalysis for Sustainable Hydrogen Storage in Formic Acid and Alcohols
Sordakis, K., Tang, C., Vogt, L. K., Junge, H., Dyson, P. J., Beller, M., & Laurenczy, G. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00182 · Cited by 1,110
Mellmann, D., Sponholz, P., Junge, H., & Beller, M. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00618j · Cited by 872
Liquid organic and inorganic chemical hydrides for high-capacity hydrogen storage
Zhu, Q.-L., & Xu, Q. (2015) · Energy & Environmental Science · doi:10.1039/c4ee03690e · Cited by 862
Klankermayer, J., Wesselbaum, S., Beydoun, K., & Leitner, W. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201507458 · Cited by 856
Liquid-phase chemical hydrogen storage materials
Yadav, M., & Xu, Q. (2012) · Energy & Environmental Science · doi:10.1039/c2ee22937d · Cited by 845
Liquid Organic Hydrogen Carrier (LOHC)—Assessment based on chemical and economic properties
Niermann, M., Beckendorff, A., Kaltschmitt, M., & Bonhoff, K. (2019) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2019.01.199 · Cited by 635
Hydrogen energy future with formic acid: a renewable chemical hydrogen storage system
Singh, A. K., Singh, S., & Kumar, A. (2016) · Catalysis Science & Technology · doi:10.1039/c5cy01276g · Cited by 543
Hydrogen storage: beyond conventional methods
Dalebrook, A. F., Gan, W., Grasemann, M., Moret, S., & Laurenczy, G. (2013) · Chemical Communications · doi:10.1039/c3cc43836h · Cited by 503
Towards Sustainable Production of Formic Acid
Bulushev, D. A., & Ross, J. R. H. (2018) · ChemSusChem · doi:10.1002/cssc.201702075 · Cited by 442
Bi, Q., Lin, J., Liu, Y., He, H., Huang, F., & Cao, Y. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201605961 · Cited by 357
Liquid organic hydrogen carriers
He, T., Pei, Q., & Chen, P. (2015) · Journal of Energy Chemistry · doi:10.1016/j.jechem.2015.08.007 · Cited by 272
Production of hydrogen peroxide as a sustainable solar fuel from water and dioxygen
Kato, S., Jung, J., Suenobu, T., & Fukuzumi, S. (2013) · Energy & Environmental Science · doi:10.1039/c3ee42815j · Cited by 270
Self-citationZinc Catalysts for On-Demand Hydrogen Generation and Carbon Dioxide Functionalization
Sattler, W., & Parkin, G. (2012) · Journal of the American Chemical Society · doi:10.1021/ja308500s · Cited by 260
Wang, W.-H., Hull, J. F., Muckerman, J. T., Fujita, E., & Himeda, Y. (2012) · Energy & Environmental Science · doi:10.1039/c2ee21888g · Cited by 256
Enabling storage and utilization of low-carbon electricity: power to formic acid
Chatterjee, S., Dutta, I., Lum, Y., Lai, Z., & Huang, K.-W. (2021) · Energy & Environmental Science · doi:10.1039/d0ee03011b · Cited by 255
Bi, Q., Lin, J., Liu, Y., He, H., Huang, F., & Cao, Y. (2016) · Angewandte Chemie · doi:10.1002/ange.201605961 · Cited by 44
Metadata
- Authors
- Maenaka, Y., Suenobu, T., & Fukuzumi, S.
- Venue
- Energy & Environmental Science
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 5
- Issue
- 6
- Pages
- 7360
- ISSN
- 1754-5692 (ISSN-L)
- 1754-5706
- OpenAlex
- W2095825218
- Cited by
- 209
- References
- 1
- FWCI
- 10.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.