The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Integration of field effect transistor-based biosensors with a digital microfluidic device for a lab-on-a-chip application
Abstract
A new platform for lab-on-a-chip system is suggested that utilizes a biosensor array embedded in a digital microfluidic device. With field effect transistor (FET)-based biosensors embedded in the middle of droplet-driving electrodes, the proposed digital microfluidic device can electrically detect avian influenza antibody (anti-AI) in real time by tracing the drain current of the FET-based biosensor without a labeling process. Digitized transport of a target droplet enclosing anti-AI from an inlet to the embedded sensor is enabled by the actuation of electrowetting-on-dielectrics (EWOD). A reduction of the drain current is observed when the target droplet is merged with a pre-existing droplet on the embedded sensor. This reduction of the drain current is attributed to the specific binding of the antigen and the antibody of the AI. The proposed hybrid device consisting of the FET-based sensor and an EWOD device, built on a coplanar substrate by monolithic integration, is fully compatible with current fabrication technology for control and read-out circuitry. Such a completely electrical manner of inducing the transport of bio-molecules, the detection of bio-molecules, the recording of signals, signal processing, and the data transmission process does not require a pump, a fluidic channel, or a bulky transducer. Thus, the proposed platform can contribute to the construction of an all-in-one chip.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Srinivasan, V., Pamula, V. K., & Fair, R. B. (2004) · Lab on a Chip · doi:10.1039/b403341h · Cited by 1,066
Digital microfluidics: is a true lab-on-a-chip possible?
Fair, R. B. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0161-8 · Cited by 1,063
A dielectric-modulated field-effect transistor for biosensing
Im, H., Huang, X.-J., Gu, B., & Choi, Y.-K. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.180 · Cited by 635
Self-citationSubthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
The Digital Revolution: A New Paradigm for Microfluidics
Abdelgawad, M., & Wheeler, A. R. (2009) · Advanced Materials · doi:10.1002/adma.200802244 · Cited by 382
Integrated polymerase chain reaction chips utilizing digital microfluidics
Chang, Y.-H., Lee, G.-B., Huang, F.-C., Chen, Y.-Y., & Lin, J.-L. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-8171-y · Cited by 324
Moon, H., Wheeler, A. R., Garrell, R. L., Loo, J. A., & Kim, C.-J. ?. (2006) · Lab on a Chip · doi:10.1039/b601954d · Cited by 296
Cited by
Luka, G., Ahmadi, A., Najjaran, H., Alocilja, E., DeRosa, M., Wolthers, K., Malki, A., Aziz, H., Althani, A., & Hoorfar, M. (2015) · Sensors · doi:10.3390/s151229783 · Cited by 566
“According to the International Union of Pure and Applied Chemistry (IUPAC) [11], a biosensor is defined as “an independently integrated receptor transducer device, which is capable of providing selective quantitative or semi-quantitative analytical information using a biological recognition element”.”
BackgroundA review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
Foudeh, A. M., Fatanat Didar, T., Veres, T., & Tabrizian, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40630f · Cited by 457
Digital microfluidics: a versatile tool for applications in chemistry, biology and medicine
Jebrail, M. J., Bartsch, M. S., & Patel, K. D. (2012) · Lab on a Chip · doi:10.1039/c2lc40318h · Cited by 324
Kovarik, M. L., Ornoff, D. M., Melvin, A. T., Dobes, N. C., Wang, Y., Dickinson, A. J., Gach, P. C., Shah, P. K., & Allbritton, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac3031543 · Cited by 218
Lagus, T. P., & Edd, J. F. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/11/114005 · Cited by 213
“On the other hand, ‘digital microfluidics’ utilizes microfabricated electrode arrays programmed to move, mix, react, analyse and split droplets through electrowetting on a dielectric-coated substrate [9, 10].”
BackgroundYang, C., Gan, X., Zeng, Y., Xu, Z., Xu, L., Hu, C., Ma, H., Chai, B., Hu, S., & Chai, B. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115723 · Cited by 88
Optical Biosensors for Diagnostics of Infectious Viral Disease: A Recent Update
Sharma, A., Mishra, R. K., Goud, K. Y., Mohamed, M. A., Kummari, S., Tiwari, S., Li, Z., Narayan, R. J., Stanciu, L., & Marty, J. (2021) · Diagnostics · doi:10.3390/diagnostics11112083 · Cited by 85
Biosensors Based on Microfluidic Devices Lab-on-a-Chip and Microfluidic Technology
Nikoleli, G., Siontorou, C. G., Nikolelis, D. P., Bratakou, S., Karapetis, S. K., & Tzamtzis, N. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813855-7.00013-1 · Cited by 96
Recent Advances in Graphene Field‐Effect Transistor Toward Biological Detection
Sun, M., Zhang, C., Lu, S., Mahmood, S., Wang, J., Sun, C., Pang, J., Han, L. G., & Liu, H. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202405471 · Cited by 90
Rackus, D. G., Dryden, M. D. M., Lamanna, J., Zaragoza, A. A., Lam, B., Kelley, S. O., & Wheeler, A. R. (2015) · Lab on a Chip · doi:10.1039/c5lc00660k · Cited by 68
Advances in integrated digital microfluidic platforms for point-of-care diagnosis: a review
Zhang, Y., & Liu, Y. (2022) · Sensors & Diagnostics · doi:10.1039/d2sd00031h · Cited by 63
Perspectives on digital microfluidics
Freire, S. L. S. (2016) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2016.08.007 · Cited by 64
Zhang, Q., Zhang, M., Djeghlaf, L., Bataille, J., Gamby, J., Haghiri‐Gosnet, A., & Pallandre, A. (2017) · Electrophoresis · doi:10.1002/elps.201600429 · Cited by 61
A Vertically Stacked Nanosheet Gate-All-Around FET for Biosensing Application
Li, C., Liu, F., Han, R., & Zhuang, Y. (2021) · IEEE Access · doi:10.1109/access.2021.3074906 · Cited by 60
“Field-effect transistor (FET) based biosensors have drawn increasing attention in the field of medical and food security for label-free detection of biomolecules [1], [2].”
BackgroundSpecific and label-free immunosensing of protein-protein interactions with silicon-based immunoFETs
Bhattacharyya, I. M., Cohen, S., Shalabny, A., Bashouti, M. Y., Akabayov, B., & Shalev, G. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.03.003 · Cited by 60
Microfluidic Devices for Label-Free DNA Detection
Dutta, G., Rainbow, J., Zupančič, U., Papamatthaiou, S., Estrela, P., & Moschou, D. C. (2018) · Chemosensors · doi:10.3390/chemosensors6040043 · Cited by 59
“With the realization of all the previously reported efforts, the true potential of Lab-on-Chip technology can be realized in sample-in-answer-out devices.”
BackgroundInfluentialTong, Z., Shen, C., Li, Q., Yin, H., & Mao, H. (2023) · The Analyst · doi:10.1039/d2an01707e · Cited by 56
Kim, J.-Y., Choi, K., Moon, D., Ahn, J., Park, T. J., Lee, S. Y., & Choi, Y. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.08.036 · Cited by 59
“Therefore, a passivation layer (Kim et al., 2012; Choi et al., 2012) is necessary, and its surface wettability may result in an enhancement of sensitivity.”
BackgroundSelf-citation“Plug-n-Play” Sensing with Digital Microfluidics
de Campos, R. P. S., Rackus, D. G., Shih, R., Zhao, C., Liu, X., & Wheeler, A. R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05375 · Cited by 54
Mukhopadhyay, S. J., Majumdar, B., Chappanda, K. N., Mukhopadhyay, S. C., & Kanungo, S. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3103998 · Cited by 55
Samiei, E., Luka, G., Najjaran, H., & Hoorfar, M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.03.035 · Cited by 47
“This requires the removal of certain parts of the hydrophobic layer on the DMF device (Malic et al., 2011; Choi et al., 2012).”
BackgroundMethodInfluentialLab-on-chip systems for integrated bioanalyses
Conde, J. P., Madaboosi, N., Soares, R. R. G., Fernandes, J. T. S., Novo, P., Moulas, G., & Chu, V. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150013 · Cited by 52
Kuşcu, M., & Akan, Ö. B. (2018) · PLoS ONE · doi:10.1371/journal.pone.0192202 · Cited by 41
“…to the studies targeting microfluidic surface-based biosensing technologies, such as planar thin gold film SPR sensors [10], semiconductor bioFETs [11], a considerable amount of efforts has been devoted to modeling and control of the complex interplay between convection, diffusion and reaction to…”
BackgroundWoo, K., Kang, W., Lee, K., Lee, P., Kim, Y., Yoon, T., Cho, C., Park, K., Ha, M.-W., & Lee, H. H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112186 · Cited by 35
Raut, P., Nanda, U., & Panda, D. K. (2023) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/acc35a · Cited by 32
Chen, T., Yang, T.-H., Wu, N.-T., Chen, Y.-T., & Huang, J. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.01.050 · Cited by 29
Liang, T., Qiu, Y. L., Gan, Y., Sun, J., Zhou, S., Wan, H., & Wang, P. (2019) · Sensors · doi:10.3390/s19194294 · Cited by 29
Tayal, S., Majumdar, B., Bhattacharya, S., & Kanungo, S. (2022) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2022.3172702 · Cited by 28
“The compatibility with complementary metal-oxide-semiconductor process flow and the scope of on-chip integration of FET biosensors are considered highly encouraging for the lab-on-chip (LOC) based point-of-care (POC) diagnosis applications [2]–[4].”
BackgroundKanungo, S., Majumdar, B., Mukhopadhyay, S. C., Som, D., Chattopadhyay, S., & Rahaman, H. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2994295 · Cited by 27
“2994295 sensor has emerged as one of the most promising candidates for point of care (POC) diagnosis applications that have opened up exciting opportunities in the field of medical biology, starting from gene sequencing to early detection of fatal diseases like cancer [1]–[5].”
BackgroundBae, B., Baek, Y., Yang, J., Lee, H., Sonnadara, C. S. S., Jung, S., Park, M., Lee, D., Kim, S., Giri, G., et al. (2023) · InfoMat · doi:10.1002/inf2.12471 · Cited by 24
Microfluidics enhanced biosensor technology for advancing food safety monitoring
Wu, G., Li, H., Chen, J., Lai, K. W. C., Xiong, L., & Yang, R. (2024) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2024.104556 · Cited by 25
Peng, Q., Zhang, M., & Shi, G. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c05164 · Cited by 23
Electroosmosis with Augmented Mixing in Rigid to Flexible Microchannels with Surface Patterns
Mitra, S., Maity, S., Sutradhar, S., & Bandyopadhyay, D. (2019) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.9b04257 · Cited by 22
Yin, T., Song, J., Hao, X., Wen, Y., Yang, P., Gao, C., Cui, R., Li, D., Hu, Y., Xu, L., et al. (2025) · ACS Nano · doi:10.1021/acsnano.5c18891 · Cited by 21
Sultan, S. M., de Planque, M. R. R., Ashburn, P., & Chong, H. M. H. (2017) · Journal of Nanomaterials · doi:10.1155/2017/5413705 · Cited by 21
Ashima, Vaithiyanathan, D., & Raj, B. (2023) · Silicon · doi:10.1007/s12633-022-02272-8 · Cited by 27
Memristive Biosensors Integration With Microfluidic Platform
Vallero, A., Tzouvadaki, I., Puppo, F., Doucey, M., Delaloye, J.-F., Micheli, G. D., & Carrara, S. (2016) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2016.2608959 · Cited by 21
“Furthermore, a lot of research effort has been made for the integration of microfluidics to different types of nanofabricated biosensors dealing with fluid samples, since this strategy allows us to reduce waste of material and detection time by guiding the sample directly to the core of the sensor [2] [3] [4] [5] [6]…”
BackgroundEmerging Trends in Integrated Digital Microfluidic Platforms for Next-Generation Immunoassays
Su, K., Li, J., Liu, H., & Zou, Y. W. (2024) · Micromachines · doi:10.3390/mi15111358 · Cited by 20
Parmar, J. S., & Sahu, C. (2020) · IEEE Transactions on Device and Materials Reliability · doi:10.1109/tdmr.2020.3041190 · Cited by 20
“The BioFET is compatible with planar CMOS processes and can be easily integrated into digital microfluidic devices for a lab-on-chip application [6].”
MethodTheisen, J., & Davoust, L. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-014-1536-2 · Cited by 20
“…for molecular recognition at drop scale with or without EWOD technology [surface plasmon resonance (Malic et al. 2009), field effect transistor (Choi et al. 2012), cantilever detection (Leichle et al. 2006) or microresonators (Royal et al. 2013), QCM detection (Fuchiwaki et al. 2014)] rely on…”
BackgroundPalepu, J., Patel, S., Sinha, S., Mallidi, R. K., Karthik, G. V. N., Majumdar, B., Mukhopadhyay, S. C., & Kanungo, S. (2023) · Current Applied Physics · doi:10.1016/j.cap.2023.01.001 · Cited by 19
Um, T., Hong, J., Im, D. J., Lee, S. J., & Kang, I. S. (2016) · Scientific Reports · doi:10.1038/srep31901 · Cited by 17
Solid-State Microfluidics with Integrated Thin-Film Acoustic Sensors
Zhang, M., Huang, J., Lu, Y., Pang, W., Zhang, H., & Duan, X. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00412 · Cited by 15
Kim, N.-S., & Kim, J. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01211-6 · Cited by 18
“Simpli fi ed biofunctionalization strategies including silica-binding proteins enable single-step high-density immobilization, reducing process complexity while improving batch-to-batch reproducibility 135,136 .”
Self-citationA Hybrid Microfluidic Electronic Sensing Platform for Life Science Applications
Panahi, A., & Ghafar‐Zadeh, E. (2022) · Micromachines · doi:10.3390/mi13030425 · Cited by 13
“Digital microfluidics was combined with a FET sensor for bioanalysis in lab-on-a-chip [54].”
MethodIsland-ground single-plate electro-wetting on dielectric device for digital microfluidic systems
Cui, W., Zhang, M., Zhang, D., Pang, W., & Zhang, H. (2014) · Applied Physics Letters · doi:10.1063/1.4889895 · Cited by 13
Partially filled electrodes for digital microfluidic devices
Pyne, D. G., Salman, W. M., Abdelgawad, M. O., & Sun, Y. (2013) · Applied Physics Letters · doi:10.1063/1.4813260 · Cited by 12
Zhao, Y., Zheng, Z., Liu, J., Dong, X., Yang, H., Wu, A., Shi, Q., & Wang, H. (2025) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0217 · Cited by 14
“As the complexity of application tasks grows, additional functional modules, such as detection and heating modules, are integrated into digital microfluidic chips (DMCs) to broaden their application scope [ 20 , 29 – 31 ].”
Fluid Transport in Partially Shielded Electrowetting on Dielectric Digital Microfluidic Devices
Madison, A. C., Royal, M., & Fair, R. B. (2016) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2016.2561699 · Cited by 11
“Multilayer and coplanar geometries are reported for the integration of resistive heaters [21]–[24] and temperature sensors [24]; windows for on-chip optical interrogation [22], [25], [26]; microelectrodes for impedance spectroscopy [27] and particle separation based on electro- and magnetophoresis [28], [29]; as well…”
BackgroundThin-Film Transistor-Based Biosensors for Determining Stoichiometry of Biochemical Reactions
Wang, Y., Chen, T., Yang, T.-H., Chang, C., Yang, T., Lo, Y., & Huang, J. (2016) · PLoS ONE · doi:10.1371/journal.pone.0169094 · Cited by 10
Gowthami, U., Prakash, M. D., Satyanarayana, B. V. V., Kumar, G. P., Panigrahy, A. K., & Dwivedi, A. K. (2025) · Results in Engineering · doi:10.1016/j.rineng.2025.105754 · Cited by 10
Microfluidic-integrated graphene optical sensors for real-time and ultra-low flow velocity detection
Wu, T., Shen, J., Li, Z., Xing, F., Xin, W., Wang, Z., Liu, G., Han, X., Man, Z., & Fu, S. (2020) · Applied Surface Science · doi:10.1016/j.apsusc.2020.148232 · Cited by 9
Mammalian cell culture and analysis in digital microfluidic platforms
Gümüşcü, B. (2025) · Lab on a Chip · doi:10.1039/d5lc00250h · Cited by 7
Biosensing on Digital Microfluidics: From Sample Preparation to Detection
Samiei, E., & Hoorfar, M. (2018) · Integrated analytical systems · doi:10.1007/978-3-319-64747-0_7 · Cited by 7
Zhu, K., Lu, H., Xue, Q., Zhou, F., Guo, W., Sun, C., & Duan, X. (2024) · Lab on a Chip · doi:10.1039/d4lc00801d · Cited by 5
Characterizations of protein-ligand reaction kinetics by transistor-microfluidic integrated sensors
Chou, C.-H., Lim, J.-C., Lai, Y.-H., Chen, Y.-T., Lo, Y., & Huang, J. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.03.012 · Cited by 5
Comparative Analysis of FinFET and NSFET Architectures for Label-Free Biosensing Applications
Gowthami, U., Rao, T. S., Tata, S., Srilakshmi, K., & Prakash, M. D. (2026) · Silicon · doi:10.1007/s12633-026-03644-0 · Cited by 6
“Food security and medicine have shown a great deal of interest in label-free biomolecule detection utilizing field-effect transistor (FET) based biosensors [1, 2].”
Advances and prospects of field-effect transistor biosensors in cancer liquid biopsy
Li, Y., Han, Y., Xia, Y., Cheng, S., & Zhang, G.-J. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118821 · Cited by 6
Digital Microfluidics for Bioanalysis
Ruan, Q., Guo, J., Wang, Y., Zou, F., Lin, X., Wang, W., & Yang, C. J. (2019) · doi:10.1002/9783527818341.ch2 · Cited by 4
Hanif, M., Zahoor, F., Alzahrani, A., Duffy, R., May, Z. B., & Bashir, F. I. (2025) · Materials Science in Semiconductor Processing · doi:10.1016/j.mssp.2025.110274 · Cited by 3
Automation and interfaces for chemistry and biochemistry in digital microfluidics
Shah, G. J., Tata, U., & van Dam, R. M. (2014) · TECHNOLOGY · doi:10.1142/s2339547814300030 · Cited by 3
A Versatile Automated Platform for Micro-scale Cell Stimulation Experiments
Sinha, A., Jebrail, M. J., Kim, H., Patel, K. D., & Branda, S. S. (2013) · Journal of Visualized Experiments · doi:10.3791/50597 · Cited by 3
Microfluidic Point-of-Care Diagnostic Devices: A Contemporary Relevance
Handa, S., & Kaur, A. (2022) · Springer eBooks · doi:10.1007/978-981-16-4345-3_22 · Cited by 2
Medical Devices Development: The Bottom-Up or The Top-Down Approach?
Wacogne, B. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2017.03.00079 · Cited by 2
A Novel Thermo-FET Sensing System for Binary Chemical Solvent Monitoring Applications
Panahi, A., Tabrizi, H. O., Ayala‐Charca, G., Roshanfar, A., Ghafar-Zadeh, M., Tahernezhad, Y., Magierowski, S., & Ghafar‐Zadeh, E. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3502720 · Cited by 1
Wang, K., & Fatoyinbo, H. O. (2014) · Royal Society of Chemistry eBooks · doi:10.1039/9781849737609-00084 · Cited by 1
Measurement and analytical techniques
Grochala, D., Paleczek, A., López‐Muñoz, G. A., & Rydosz, A. M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15384-6.00003-3
Microfluidic systems in diagnostic and prognostic applications
Kotkar, A., Chandankar, S., & Kar, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95533-1.00009-6
pН-СЕНСОР С РАСШИРЕННЫМ ЗАТВОРОМ И КОНТАКТОМ К ЖИДКОСТИ НА ОБРАТНОЙ СТОРОНЕ ПОДЛОЖКИ
Кацеро, А. М., Габдрахманов, А. Э., Ryazantsev, D. V., Komarova, N. V., & Kuznetsov, A. E. (2025) · Nanoindustry Russia · doi:10.22184/1993-8578.2025.18.12s.150.154
Park, S., Lee, G., Seo, J., Yu, S. E., Kang, J., Lee, J., & Lee, Y. T. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118541
Kumar, A., Gill, S. S., & Sharma, K. (2025) · International Conference on Advancement in Electronics & Communication Engineering (AECE) · doi:10.1109/aece67531.2025.11386686
Development of a high-sensitivity Ge-source DGTFET biosensor
Kumar, A., Gill, S. S., & Sharma, K. (2026) · Analog Integrated Circuits and Signal Processing · doi:10.1007/s10470-026-02579-1 · Cited by 1
Jiang, R., Guo, J., Wang, Z., Cheng, J., Zhang, H., Zhang, Q., Zhang, L. D., ZHAO, Y., Huang, C. J., & Li, M. (2026) · The Analyst · doi:10.1039/d6an00306k
Jakher, S., & Yadav, R. (2026) · World Journal of Engineering · doi:10.1108/wje-01-2026-0029
Metadata
- Authors
- Choi, K., Kim, J.-Y., Ahn, J.-H., Choi, J.-M., Im, M., & Choi, Y.-K.
- Affiliations
- Korea Advanced Institute of Science and Technology (KR)
- Harvard University (US)
- Corresponding author
- Choi, Yang-Kyu
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 8
- Pages
- 1533
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2079944525
- Semantic Scholar
- a309d573e2c908744358f3bfe931508fb3475a96
- Cited by
- 77
- References
- 23
- Citations by year
- 2026: 7 · 2025: 7 · 2024: 7 · 2023: 6 · 2022: 5 · 2021: 3 · 2020: 5 · 2019: 5 · 2018: 6 · 2017: 3 · 2016: 8 · 2015: 2 · 2014: 5 · 2013: 3 · 2012: 5
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- field-effect transistor biosensors, digital microfluidics, electrowetting-on-dielectric, label-free biosensing, drain current, droplet transport, antigen-antibody reaction, monolithic integration
- MeSH terms
- Animals, Antibodies, Birds, Electrodes, Equipment Design, Influenza in Birds, Influenza A virus, Biosensing Techniques, Microfluidic Analytical Techniques, Limit of Detection, Electrowetting
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.