CoChat

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Integration of field effect transistor-based biosensors with a digital microfluidic device for a lab-on-a-chip application

Abstract

A new platform for lab-on-a-chip system is suggested that utilizes a biosensor array embedded in a digital microfluidic device. With field effect transistor (FET)-based biosensors embedded in the middle of droplet-driving electrodes, the proposed digital microfluidic device can electrically detect avian influenza antibody (anti-AI) in real time by tracing the drain current of the FET-based biosensor without a labeling process. Digitized transport of a target droplet enclosing anti-AI from an inlet to the embedded sensor is enabled by the actuation of electrowetting-on-dielectrics (EWOD). A reduction of the drain current is observed when the target droplet is merged with a pre-existing droplet on the embedded sensor. This reduction of the drain current is attributed to the specific binding of the antigen and the antibody of the AI. The proposed hybrid device consisting of the FET-based sensor and an EWOD device, built on a coplanar substrate by monolithic integration, is fully compatible with current fabrication technology for control and read-out circuitry. Such a completely electrical manner of inducing the transport of bio-molecules, the detection of bio-molecules, the recording of signals, signal processing, and the data transmission process does not require a pump, a fluidic channel, or a bulky transducer. Thus, the proposed platform can contribute to the construction of an all-in-one chip.

Overview

Integrity signals

Registry

Crossref · 10.1039/c2lc21203j

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Cited by

See all 77

Metadata

Authors
Choi, K., Kim, J.-Y., Ahn, J.-H., Choi, J.-M., Im, M., & Choi, Y.-K.
Affiliations
  • Korea Advanced Institute of Science and Technology (KR)
  • Harvard University (US)
Corresponding author
Choi, Yang-Kyu
Venue
Lab on a Chip
Published
2012
Volume
12
Issue
8
Pages
1533
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2079944525
Cited by
77
References
23
Citations by year
2026: 7 · 2025: 7 · 2024: 7 · 2023: 6 · 2022: 5 · 2021: 3 · 2020: 5 · 2019: 5 · 2018: 6 · 2017: 3 · 2016: 8 · 2015: 2 · 2014: 5 · 2013: 3 · 2012: 5
FWCI
3.07
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
Keywords
field-effect transistor biosensors, digital microfluidics, electrowetting-on-dielectric, label-free biosensing, drain current, droplet transport, antigen-antibody reaction, monolithic integration
MeSH terms
Animals, Antibodies, Birds, Electrodes, Equipment Design, Influenza in Birds, Influenza A virus, Biosensing Techniques, Microfluidic Analytical Techniques, Limit of Detection, Electrowetting

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.