The DOI matches its Crossref record; 100 of the 100 references it cites were found in a registry or an index.
Isothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review
Abstract
Nucleic Acid Testing (NAT) promises rapid, sensitive and specific diagnosis of infectious, inherited and genetic disease. The next generation of diagnostic devices will interrogate the genetic determinants of such conditions at the point-of-care, affording clinicians prompt reliable diagnosis from which to guide more effective treatment. The complex biochemical nature of clinical samples, the low abundance of nucleic acid targets in the majority of clinical samples and existing biosensor technology indicate that some form of nucleic acid amplification will be required to obtain clinically relevant sensitivities from the small samples used in point-of-care testing (POCT). This publication provides an overview and thorough review of existing technologies for nucleic acid amplification. The different methods are compared and their suitability for POCT adaptation are discussed. Current commercial products employing isothermal amplification strategies are also investigated. In conclusion we identify the factors impeding the integration of the methods discussed in fully automated, sample-to-answer POCT devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primer-Directed Enzymatic Amplification of DNA with a Thermostable DNA Polymerase
Saiki, R. K., Gelfand, D. H., Stoffel, S., Scharf, S. J., Higuchi, R., Horn, G. T., Mullis, K. B., & Erlich, H. A. (1988) · Science · doi:10.1126/science.2448875 · Cited by 17,719
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Holland, P. M., Abramson, R. D., Watson, R., & Gelfand, D. H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.16.7276 · Cited by 2,693
DNA Detection Using Recombination Proteins
Piepenburg, O., Williams, C. H., Stemple, D. L., & Armes, N. A. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040204 · Cited by 2,482
Genetical Implications of the Structure of Deoxyribonucleic Acid
WATSON, J. D., & CRICK, F. H. C. (1953) · Nature · doi:10.1038/171964b0 · Cited by 2,197
Accelerated reaction by loop-mediated isothermal amplification using loop primers
Nagamine, K., Hase, T., & Notomi, T. (2002) · Molecular and Cellular Probes · doi:10.1006/mcpr.2002.0415 · Cited by 2,045
Mori, Y., Nagamine, K., Tomita, N., & Notomi, T. (2001) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2001.5921 · Cited by 1,711
Bias in template-to-product ratios in multitemplate PCR
Polz, M. F., & Cavanaugh, C. M. (1998) · Applied and Environmental Microbiology · doi:10.1128/aem.64.10.3724-3730.1998 · Cited by 1,484
Mutation detection and single-molecule counting using isothermal rolling-circle amplification
Lizardi, P. M., Huang, X., Zhu, Z., Bray-Ward, P., Thomas, D. C., & Ward, D. C. (1998) · Nature Genetics · doi:10.1038/898 · Cited by 1,442
Cited by
Isothermal Amplification of Nucleic Acids
Zhao, Y., Chen, F., Li, Q., Wang, L., & Fan, C. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00428 · Cited by 1,775
Diagnosing COVID-19: The Disease and Tools for Detection
Udugama, B., Kadhiresan, P., Kozlowski, H. N., Malekjahani, A., Osborne, M., Li, V. Y. C., Chen, H., Mubareka, S., Gubbay, J. B., & Chan, W. C. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c02624 · Cited by 1,754
Recombinase polymerase amplification: Basics, applications and recent advances
Lobato, I. M., & O'Sullivan, C. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.10.015 · Cited by 1,146
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Recombinase Polymerase Amplification for Diagnostic Applications
Daher, R. K., Stewart, G., Boissinot, M., & Bergeron, M. G. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.245829 · Cited by 740
Review: a comprehensive summary of a decade development of the recombinase polymerase amplification
Li, J., Macdonald, J., & von Stetten, F. (2019) · The Analyst · doi:10.1039/c8an01621f · Cited by 648
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application
Gong, M. M., & Sinton, D. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00024 · Cited by 573
Review on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe-Desmonts, L., & Benito-Lopez, F. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 515
Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies
Jung, W., Han, J., Choi, J.-W., & Ahn, C. H. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.09.024 · Cited by 510
McConnell, E. M., Cozma, I., Mou, Q., Brennan, J. D., Lu, Y., & Li, Y. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00240f · Cited by 477
Foudeh, A. M., Fatanat Didar, T., Veres, T., & Tabrizian, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40630f · Cited by 457
Becherer, L., Borst, N., Bakheit, M., Frischmann, S., Zengerle, R., & von Stetten, F. (2020) · Analytical Methods · doi:10.1039/c9ay02246e · Cited by 429
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip
Yeh, E.-C., Fu, C.-C., Hu, L., Thakur, R., Feng, J., & Lee, L. P. (2017) · Science Advances · doi:10.1126/sciadv.1501645 · Cited by 347
Current and Emerging Legionella Diagnostics for Laboratory and Outbreak Investigations
Mercante, J. W., & Winchell, J. M. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00029-14 · Cited by 339
Reid, M. S., Le, X. C., & Zhang, H. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201712217 · Cited by 338
Ultra-sensitive and high-throughput CRISPR-p owered COVID-19 diagnosis
Huang, Z., Tian, D., Liu, Y., Lin, Z., Lyon, C. J., Lai, W., Fusco, D., Drouin, A., Yin, X., Hu, T., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112316 · Cited by 332
Jiang, Y. (., Li, B., Milligan, J. N., Bhadra, S., & Ellington, A. D. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4023978 · Cited by 292
Development and Applications of Portable Biosensors
Srinivasan, B., & Tung, S. (2015) · SLAS Technology · doi:10.1177/2211068215581349 · Cited by 262
Microfluidic Point-of-Care Testing: Commercial Landscape and Future Directions
Sachdeva, S., Davis, R. W., & Saha, A. K. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.602659 · Cited by 262
Yuan, C., Tian, T., Sun, J., Hu, M., Wang, X., Xiong, E., Cheng, M., Bao, Y., Lin, W., Jiang, J., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05597 · Cited by 257
Metadata
- Authors
- Craw, P., & Balachandran, W.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 14
- Pages
- 2469
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2141012160
- Cited by
- 766
- References
- 100
- FWCI
- 21.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.