The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Point-of-care colorimetric detection with a smartphone
Abstract
Paper-based immunoassays are becoming powerful and low-cost diagnostic tools, especially in resource-limited settings. Inexpensive methods for quantifying these assays have been shown using desktop scanners, which lack portability, and cameras, which suffer from the ever changing ambient light conditions. In this work, we introduce a novel approach of quantifying colors of colorimetric diagnostic assays with a smartphone that allows high accuracy measurements in a wide range of ambient conditions, making it a truly portable system. Instead of directly using the red, green, and blue (RGB) intensities of the color images taken by a smartphone camera, we use chromaticity values to construct calibration curves of analyte concentrations. We demonstrate the high accuracy of this approach in pH measurements with linear response ranges of 1-12. These results are comparable to those reported using a desktop scanner or silicon photodetectors. To make the approach adoptable under different lighting conditions, we developed a calibration technique to compensate for measurement errors due to variability in ambient light. This technique is applicable to a number of common light sources, such as sun light, fluorescent light, or smartphone LED light. Ultimately, the entire approach can be integrated in an "app" to enable one-click reading, making our smartphone based approach operable without any professional training or complex instrumentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Color Science, Concepts and Methods. Quantitative Data and Formulas
Wright, W. D. (1967) · Physics Bulletin · doi:10.1088/0031-9112/18/10/010 · Cited by 3,540
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Low-Cost Printing of Poly(dimethylsiloxane) Barriers To Define Microchannels in Paper
Bruzewicz, D. A., Reches, M., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac702605a · Cited by 616
Nano/Microfluidics for diagnosis of infectious diseases in developing countries
Lee, W. G., Kim, Y.-G., Chung, B. G., Demirci, U., & Khademhosseini, A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.016 · Cited by 357
Fu, E., Liang, T., Spicar-Mihalic, P., Houghtaling, J., Ramachandran, S., & Yager, P. (2012) · Analytical Chemistry · doi:10.1021/ac300689s · Cited by 272
Wang, S., Zhao, X., Khimji, I., Akbas, R., Qiu, W., Edwards, D., Cramer, D. W., Ye, B., & Demirci, U. (2011) · Lab on a Chip · doi:10.1039/c1lc20479c · Cited by 254
Advances in developing HIV-1 viral load assays for resource-limited settings
Wang, S., Xu, F., & Demirci, U. (2010) · Biotechnology Advances · doi:10.1016/j.biotechadv.2010.06.004 · Cited by 158
A simple and smart telemedicine device for developing regions: a pocket-sized colorimetric reader
Lee, D.-S., Jeon, B. G., Ihm, C., Park, J., & Jung, M. Y. (2010) · Lab on a Chip · doi:10.1039/c0lc00209g · Cited by 112
Microfluidic whole-blood immunoassays
Jiang, H. M., Weng, X., & Li, D. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0718-9 · Cited by 111
Color for Science, Art and Technology
NASSAU, K. (1998) · Cited by 107
Plastic ELISA-on-a-Chip Based on Sequential Cross-Flow Chromatography
Cho, J., Han, S.-M., Paek, E.-H., Cho, I.-H., & Paek, S. (2006) · Analytical Chemistry · doi:10.1021/ac051453v · Cited by 101
Telemedicine and teledermatology: Past, present and future
Wurm, E. M. T., Hofmann‐Wellenhof, R., Wurm, R., & Soyer, H. P. (2007) · JDDG Journal der Deutschen Dermatologischen Gesellschaft · doi:10.1111/j.1610-0387.2007.06440.x · Cited by 95
Rapid automated cell quantification on HIV microfluidic devices
Alyassin, M. A., Moon, S., Keleş, H. O., Manzur, F., Lin, R. L., Hæggström, E., Kuritzkes, D. R., & Demirci, U. (2009) · Lab on a Chip · doi:10.1039/b911882a · Cited by 76
Tohda, K., & Gratzl, M. (2006) · Analytical Sciences · doi:10.2116/analsci.22.383 · Cited by 35
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Light in diagnosis, therapy and surgery
Yun, S. H., & Kwok, S. J. J. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0008 · Cited by 793
Emerging Technologies for Next-Generation Point-of-Care Testing
Vashist, S. K., Luppa, P. B., Yeo, L. Y., Ozcan, A., & Luong, J. H. T. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.001 · Cited by 705
Metadata
- Authors
- Shen, L., Hagen, J. A., & Papautsky, I.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 21
- Pages
- 4240
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2120243796
- Cited by
- 609
- References
- 17
- FWCI
- 17.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.