CoChat

Cross talk between cancer and immune cells: exploring complex dynamics in a microfluidic environment

The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.

Abstract

The reconstitution of a complex microenvironment on microfluidic chips is one of the cornerstones to demonstrate the improved flexibility of these devices with respect to macroscale in vitro approaches. In this work, we realised an on-chip model to investigate the interactions between cancer and immune system. To this end, we exploited mice deficient (Knock Out, KO) for interferon regulatory factor 8 (IRF-8), a transcription factor essential for the induction of competent immune responses, to investigate how IRF-8 gene expression contributes to regulate immune and melanoma cells crosstalk. In vivo, IRF-8 KO mice are highly permissive to B16 melanoma growth due to failure of immune cells to properly exert immunosurveillance. B16 cells and immune cells isolated from the spleen of wild type (WT) and IRF-8 KO mice were co-cultured for one week in a PDMS platform and monitored by fluorescence microscopy and time-lapse recordings. We observed that WT spleen cells migrated through microchannels connecting the culturing chambers towards B16 cells and tightly interacted with tumor cells, forming clusters of activation. In contrast, IRF-8 KO immune cells poorly interacted with melanoma cells. In parallel, B16 cells were more attracted towards microchannels, acquiring a more invasive behaviour in the presence of IRF-8 KO spleen cells, with respect to WT cells. Our results strongly confirm the in vivo observations and highlight the value of on-chip co-culture systems as a useful in vitro…

Overview

Integrity signals

Registry

Crossref · 10.1039/c2lc40887b

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

1 retracted

Research works printed but not linked: 8

  1. Khetani, 2008, Nat Biotechnol, 26
  2. Huh, 2010, Science, 328
  3. Weibel, 2007, Nature Reviews, 5, 210
  4. Prager-Khoutorsky, 2011, Nature Cell Biology, 13
  5. Ghiringhelli, Cancer Immunol Immunother, 2006
  6. Shahshahan, 2011, Am J Cancer Res, 1, 913
  7. Poste, 1982, Cancer Res, 42, 2770
  8. Mattei, 2009, Eur. J. Immunol., 39, S621, 10.1002/eji.200939233 · DOI · Paper page

Cited by

See all 162

Metadata

Authors
Businaro, L., De Ninno, A., Schiavoni, G., Lucarini, V., Ciasca, G., Gerardino, A., Belardelli, F., Gabriele, L., & Mattei, F.
Affiliations
  • National Research Council (IT)
  • Istituto Superiore di Sanità (IT)
Corresponding author
  • Businaro, Luca
  • Mattei, Fabrizio
Venue
Lab Chip
Published
2013
Volume
13
Issue
2
Pages
229-239
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2033651938
Cited by
162
References
52
Citations by year
2026: 8 · 2025: 8 · 2024: 14 · 2023: 11 · 2022: 17 · 2021: 18 · 2020: 11 · 2019: 14 · 2018: 18 · 2017: 12 · 2016: 10 · 2015: 7 · 2014: 4 · 2013: 8
FWCI
3.64
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
  • IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
Keywords
IRF8, B16 melanoma, tumor surveillance, microfluidics, PDMS microchannel, leukocyte migration, tumor invasion, splenocytes, anti-tumor therapy
MeSH terms
Interferon Regulatory Factor-8, Animals, Cell Communication, Cell Movement, Cells, Cultured, Flow Cytometry, Melanoma, Mice, Inbred C57BL, Microscopy, Fluorescence, Spleen, Stress, Physiological, Mice, Knockout, Coculture Techniques, Microfluidic Analytical Techniques, Interferon Regulatory Factors, Mice, Time-Lapse Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.