The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Smartphone based health accessory for colorimetric detection of biomarkers in sweat and saliva
Abstract
The mobile health market is rapidly expanding and portable diagnostics tools offer an opportunity to decrease costs and increase the availability of healthcare. Here we present a smartphone based accessory and method for the rapid colorimetric detection of pH in sweat and saliva. Sweat pH can be correlated to sodium concentration and sweat rate in order to indicate to users the proper time to hydrate during physical exercise and avoid the risk of muscle cramps. Salivary pH below a critical threshold is correlated with enamel decalcification, an acidic breakdown of calcium in the teeth. We conduct a number of human trials with the device on a treadmill to demonstrate the ability to monitor changes in sweat pH due to exercise and electrolyte intake and predict optimal hydration. Additionally, we perform trials to measure salivary pH over time to monitor the effects of diet on oral health risks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Journal of the Canadian Dental Association
Neustadt, E. (1937) · International Journal of Orthodontia and Oral Surgery · doi:10.1016/s1072-3498(37)80084-9 · Cited by 706
Point-of-care colorimetric detection with a smartphone
Shen, L., Hagen, J. A., & Papautsky, I. (2012) · Lab on a Chip · doi:10.1039/c2lc40741h · Cited by 609
What is the critical pH and why does a tooth dissolve in acid?
Dawes, C. (2003) · PubMed · Cited by 455
Variations in Regional Sweat Composition in Normal Human Males
Patterson, M. J., Galloway, S. D. R., & Nimmo, M. A. (2000) · Experimental Physiology · doi:10.1111/j.1469-445x.2000.02058.x · Cited by 438
A personalized food allergen testing platform on a cellphone
Coskun, A. F., Wong, J., Khodadadi, D., Nagi, R., Tey, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc41152k · Cited by 280
Hydration and Physical Performance
Murray, B. (2007) · Journal of the American College of Nutrition · doi:10.1080/07315724.2007.10719656 · Cited by 276
Control of skin blood flow, sweating, and heart rate: role of skin vs. core temperature.
Wyss, C. R., Brengelmann, G. L., Johnson, J. M., Rowell, L. B., & Niederberger, M. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.36.6.726 · Cited by 217
Exercise-Associated Hyponatremia
Rosner, M. H., & Kirven, J. (2007) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.02730806 · Cited by 215
Curto, V. F., Fay, C., Coyle, S., Byrne, R., O’Toole, C., Barry, C., Hughes, S., Moyna, N., Diamond, D., & Benito-Lopez, F. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.06.048 · Cited by 213
Acute effects of dehydration on sweat composition in men during prolonged exercise in the heat
Morgan, R. M., Patterson, M. J., & Nimmo, M. A. (2004) · Acta Physiologica Scandinavica · doi:10.1111/j.1365-201x.2004.01305.x · Cited by 192
Sodium ion concentration vs. sweat rate relationship in humans
Buono, M. J., Ball, K. D., & Kolkhorst, F. W. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00015.2007 · Cited by 186
Sweat and Sodium Losses in NCAA Football Players: A Precursor to Heat Cramps?
Stofan, J. R., Zachwieja, J. J., Horswill, C. A., Murray, R. D., Anderson, S. A., & Eichner, E. R. (2005) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.15.6.641 · Cited by 125
Death from Hyponatremia as a Result of Acute Water Intoxication in an Army Basic Trainee
Garigan, T. P., & Ristedt, D. E. (1999) · Military Medicine · doi:10.1093/milmed/164.3.234 · Cited by 122
Sweat Composition in Relation to Rate of Sweating in Patients with Cystic Fibrosis of the Pancreas
Emrich, H. M., Stoll, E., Friolet, B., Colombo, J. P., Richterich, R., & Rossi, E. (1968) · Pediatric Research · doi:10.1203/00006450-196811000-00004 · Cited by 122
Critical pH in resting and stimulated whole saliva in groups of children and adults
Anderson, P., Hector, M. P., & Rampersad, M. A. (2001) · International Journal of Paediatric Dentistry · doi:10.1046/j.1365-263x.2001.00293.x · Cited by 121
Forecasting the Cost of U.S. Health Care in 2040
Fogel, R. W. (2008) · Journal of Policy Modeling · doi:10.1016/j.jpolmod.2009.05.004 · Cited by 60
Acid Production From Different Carbohydrate Foods in Plaque and Saliva
Ludwig, T. G., & Bibby, B. G. (1957) · Journal of Dental Research · doi:10.1177/00220345570360011801 · Cited by 41
Cited by
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Lim, H., Kim, H. S., Qazi, R., Kwon, Y., Jeong, J., & Yeo, W. (2020) · Advanced Materials · doi:10.1002/adma.201901924 · Cited by 1,002
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Metadata
- Authors
- Oncescu, V., O'Dell, D., & Erickson, D.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 16
- Pages
- 3232
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2130329278
- Cited by
- 362
- References
- 18
- FWCI
- 19.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.