CoChat

A microfluidic device designed to induce media flow throughout pancreatic islets while limiting shear-induced damage

Silva, Pamuditha N., Green, Brenda J., Altamentova, Svetlana M., Rocheleau, Jonathan V. · 2013 · Lab on a Chip
Cited by 70

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Pancreatic islets are heavily vascularized in vivo with fenestrated endothelial cells (ECs) to facilitate blood glucose-sensing and endocrine hormone secretion. The close proximity of insulin secreting beta cells and ECs also plays a critical role in modulating the proliferation and survival of both cell types with the mechanisms governing this interaction poorly understood. Isolated islets lose EC morphology and mass over a period of days in culture prohibiting study of this interaction in vitro. The loss of ECs also limits the efficacy of islet transplant revascularization in the treatment of Type 1 diabetes. We previously showed that microfluidically driven flow positively affects beta-cell function and EC survival in culture due to enhanced transport of media into the tissue. However, holding islets stationary in media flow using a dam-wall design also resulted in reduced glucose-stimulated metabolic and Ca(2+) responses at the periphery of the tissue consistent with shear-induced damage. We have now created a device that traps islets into sequential cup-shaped nozzles. This hydrodynamic trap design limits flow velocity around the perimeter of the islet while enhancing media flow through the tissue. We demonstrate the feasibility of this device to dynamically treat and collect effluent from islets. We further show that treating islets in this device enhances EC morphology without reducing glucose-stimulate Ca(2+) responses. These data reveal a microfluidic device to study EC and endocrine cell interaction that can be further leveraged to prime islets prior to transplantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3lc50680k

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 70

Metadata

Authors
Silva, P. N., Green, B. J., Altamentova, S. M., & Rocheleau, J. V.
Venue
Lab on a Chip
Published
2013
Volume
13
Issue
22
Pages
4374
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W1995599967
Cited by
70
References
8
FWCI
3.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A microfluidic device designed to induce media flow throughout pancreatic islets while limiting shear-induced damage. https://app.cochat.ai/papers/10.1039/c3lc50680k
The paper
Silva, P. N., Green, B. J., Altamentova, S. M., & Rocheleau, J. V. (2013). A microfluidic device designed to induce media flow throughout pancreatic islets while limiting shear-induced damage. Lab on a Chip. https://doi.org/10.1039/c3lc50680k

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.