The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Engineering interconnected 3D vascular networks in hydrogels using molded sodium alginate lattice as the sacrificial template
Abstract
We engineer interconnected 3D vascular networks in hydrogels using molded sodium alginate lattice as sacrificial templates. The size and morphology of simulated vascular networks were well controlled and a fully-developed endothelial layer was formed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Rapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
Cited by
Progress and potential in organoid research
Rossi, G., Manfrin, A., & Lutolf, M. P. (2018) · Nature Reviews Genetics · doi:10.1038/s41576-018-0051-9 · Cited by 1,182
Coaxial nozzle-assisted 3D bioprinting with built-in microchannels for nutrients delivery
Gao, Q., He, Y., Fu, J.-Z., Liu, A., & Ma, L. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.05.031 · Cited by 630
Microfluidic fabrication of microparticles for biomedical applications
Li, W., Zhang, L., Ge, X., Xu, B., Zhang, W., Qu, L., Choi, C.-H., Xu, J., Zhang, A., Lee, H., et al. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00263g · Cited by 585
Microfluidic 3D cell culture: from tools to tissue models
van Duinen, V., Trietsch, S. J., Joore, J., Vulto, P., & Hankemeier, T. (2015) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2015.05.002 · Cited by 500
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
Surface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices
Akther, F., Yakob, S. B., Nguyen, N.-T., & Ta, H. T. (2020) · Biosensors · doi:10.3390/bios10110182 · Cited by 182
Cardiovascular organ-on-a-chip platforms for drug discovery and development
Ribas, J., Sadeghi, H., Manbachi, A., Leijten, J., Brinegar, K., Zhang, Y. S., Ferreira, L., & Khademhosseini, A. (2016) · Applied In Vitro Toxicology · doi:10.1089/aivt.2016.0002 · Cited by 161
Flow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
Wang, X., Sun, Q., & Pei, J. (2018) · Micromachines · doi:10.3390/mi9100493 · Cited by 106
Self-citationRecapitulating the vasculature using ORGAN-ON-CHIP technology
Pollet, A. M. A. O., & den Toonder, J. M. J. (2020) · Bioengineering · doi:10.3390/bioengineering7010017 · Cited by 73
In vitro micro-physiological models for translational immunology
Ramadan, Q., & Gijs, M. A. M. (2015) · Lab on a Chip · doi:10.1039/c4lc01271b · Cited by 41
Fang, Y., Sun, W., Zhang, T., & Xiong, Z. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2021.121298 · Cited by 40
Metadata
- Authors
- Wang, X.-Y., Jin, Z.-H., Gan, B.-W., Lv, S.-W., Xie, M., & Huang, W.-H.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 14
- Issue
- 15
- Pages
- 2709-2716
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1980857674
- Cited by
- 166
- References
- 3
- FWCI
- 7.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.