Microengineered peripheral nerve-on-a-chip for preclinical physiological testing
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
A microscale, organotypic in vitro model of sensory peripheral nerve tissue may be assessed with clinically-relevant morphological and physiological measures for use as a drug screening assay for selecting promising lead compounds with higher chances of late-stage success.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The price of innovation: new estimates of drug development costs
DiMasi, J. A., Hansen, R. W., & Grabowski, H. G. (2003) · Journal of Health Economics · doi:10.1016/s0167-6296(02)00126-1 · Cited by 4,265
Can the pharmaceutical industry reduce attrition rates?
Kola, I., & Landis, J. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1470 · Cited by 4,167
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Why Drugs Fail - A Study on Side Effects in New Chemical Entities
Schuster, D., Laggner, C., & Langer, T. (2005) · Current Pharmaceutical Design · doi:10.2174/138161205774414510 · Cited by 417
Muratore, C. R., Rice, H. C., Srikanth, P., Callahan, D. G., Shin, T., Benjamin, L. N. P., Walsh, D. M., Selkoe, D. J., & Young-Pearse, T. L. (2014) · Human Molecular Genetics · doi:10.1093/hmg/ddu064 · Cited by 379
Biomimetic tissues on a chip for drug discovery
Ghaemmaghami, A. M., Hancock, M. J., Harrington, H., Kaji, H., & Khademhosseini, A. (2012) · Drug Discovery Today · doi:10.1016/j.drudis.2011.10.029 · Cited by 359
Approaching the in vitro clinical trial: engineering organs on chips
Capulli, A. K., Tian, K., Mehandru, N., Bukhta, A., Choudhury, S. F., Suchyta, M., & Parker, K. K. (2014) · Lab on a Chip · doi:10.1039/c4lc00276h · Cited by 111
Modality-Specific Axonal Regeneration: Toward Selective Regenerative Neural Interfaces
Lotfi, P., Garde, K., Chouhan, A. K., Bengali, E., & Romero-Ortega, M. I. (2011) · Frontiers in Neuroengineering · doi:10.3389/fneng.2011.00011 · Cited by 42
Cited by
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Advances in Hydrogels in Organoids and Organs‐on‐a‐Chip
Liu, H., Wang, Y., Cui, K., Guo, Y., Zhang, X., & Qin, J. (2019) · Advanced Materials · doi:10.1002/adma.201902042 · Cited by 353
Gribi, S., du Bois de Dunilac, S., Ghezzi, D., & Lacour, S. P. (2018) · Nature Communications · doi:10.1038/s41467-018-06895-7 · Cited by 72
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
“microengineered a biomimetic sensory neural fiber tract model capable of electrophysiological and histopathological assessment (Figure 3J) (Huval et al., 2015).”
BackgroundAdvances in microfluidic 3D cell culture for preclinical drug development
(2022) · Progress in Molecular Biology and Translational Science · doi:10.1016/bs.pmbts.2021.07.022 · Cited by 23
Metadata
- Authors
- Huval, R. M., Miller, O. H., Curley, J. L., Fan, Y., Hall, B. J., & Moore, M. J.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 15
- Issue
- 10
- Pages
- 2221-2232
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2050064271
- Cited by
- 71
- References
- 8
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.