A microfabricated nerve-on-a-chip platform for rapid assessment of neural conduction in explanted peripheral nerve fibers
Open accessAbstract
Peripheral nerves are anisotropic and heterogeneous neural tissues. Their complex physiology restricts realistic in vitro models, and high resolution and selective probing of axonal activity. Here, we present a nerve-on-a-chip platform that enables rapid extracellular recording and axonal tracking of action potentials collected from tens of myelinated fibers. The platform consists of microfabricated stimulation and recording microchannel electrode arrays. First, we identify conduction velocities of action potentials traveling through the microchannel and propose a robust data-sorting algorithm using velocity selective recording. We optimize channel geometry and electrode spacing to enhance the algorithm reliability. Second, we demonstrate selective heat-induced neuro-inhibition of peripheral nerve activity upon local illumination of a conjugated polymer (P3HT) blended with a fullerene derivative (PCBM) coated on the floor of the microchannel. We demonstrate the nerve-on-a-chip platform is a versatile tool to optimize the design of implantable peripheral nerve interfaces and test selective neuromodulation techniques ex vivo.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Microchannel electrodes' good recording properties and ease of use have found use for them in ex vivo applications such as nerve-on-a-chip platforms.
“Their good recording properties and ease of use have, however, found use for them in ex vivo applications such as nerve-on-a-chip platforms (Gribi et al., 2018).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Gribi et al., 2018
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · see citing works
The dual effect of membrane potential on sodium conductance in the giant axon of Loligo
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004719 · Cited by 1,608 · see citing works
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · see citing works
CONDUCTION VELOCITY AND DIAMETER OF NERVE FIBERS
Hursh, J. B. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.1.131 · Cited by 916 · see citing works
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862 · see citing works
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
Soft, stretchable, fully implantable miniaturized optoelectronic systems for wireless optogenetics
Park, S. I., Brenner, D. S., Shin, G., Morgan, C. D., Copits, B. A., Chung, H. U., Pullen, M. Y., Noh, K. N., Davidson, S., Oh, S. J., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3415 · Cited by 794 · see citing works
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · see citing works
Local control of neurite development by nerve growth factor
Campenot, R. B. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.10.4516 · Cited by 747 · see citing works
A brain–spine interface alleviating gait deficits after spinal cord injury in primates
Capogrosso, M., Milekovic, T., Borton, D., Wagner, F., Moraud, E. M., Mignardot, J.-B., Buse, N., Gandar, J., Barraud, Q., Xing, D., et al. (2016) · Nature · doi:10.1038/nature20118 · Cited by 635 · see citing works
Automated whole-cell patch-clamp electrophysiology of neurons in vivo
Kodandaramaiah, S. B., Franzesi, G. T., Chow, B. Y., Boyden, E. S., & Forest, C. R. (2012) · Nature Methods · doi:10.1038/nmeth.1993 · Cited by 245 · see citing works
Stasheff, S. F. (2008) · Journal of Neurophysiology · doi:10.1152/jn.00144.2007 · Cited by 230 · see citing works
Virally mediated optogenetic excitation and inhibition of pain in freely moving nontransgenic mice
Iyer, S. M., Montgomery, K. L., Towne, C. L., Lee, S. Y., Ramakrishnan, C., Deisseroth, K. A., & Delp, S. L. (2014) · Nature Biotechnology · doi:10.1038/nbt.2834 · Cited by 218 · see citing works
Dragas, J., Viswam, V., Shadmani, A., Chen, Y., Bounik, R., Stettler, A., Radivojević, M., Geissler, S. A., Obien, M. E. J., Müller, J., et al. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2686580 · Cited by 207 · see citing works
Photothermal cellular stimulation in functional bio-polymer interfaces
Martino, N., Feyen, P., Porro, M., Bossio, C., Zucchetti, E., Ghezzi, D., Benfenati, F., Lanzani, G., & Antognazza, M. R. (2015) · Scientific Reports · doi:10.1038/srep08911 · Cited by 168 · see citing works
Self-citationOptogenetic Control of Targeted Peripheral Axons in Freely Moving Animals
Towne, C., Montgomery, K. L., Iyer, S. M., Deisseroth, K., & Delp, S. L. (2013) · PLoS ONE · doi:10.1371/journal.pone.0072691 · Cited by 156 · see citing works
A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007186 · Cited by 123 · see citing works
Self-citationTwo-dimensional monitoring of spiking networks in acute brain slices
Egert, U., Heck, D. H., & Aertsen, A. (2002) · Experimental Brain Research · doi:10.1007/s00221-001-0932-5 · Cited by 122 · see citing works
New technologies for the assessment of neuropathies
Gasparotti, R., Padua, L., Briani, C., & Lauria, G. (2017) · Nature Reviews Neurology · doi:10.1038/nrneurol.2017.31 · Cited by 104 · see citing works
Whole-Cell Recording of Neuronal Membrane Potential during Behavior
Petersen, C. C. H. (2017) · Neuron · doi:10.1016/j.neuron.2017.06.049 · Cited by 100 · see citing works
Light-evoked hyperpolarization and silencing of neurons by conjugated polymers
Feyen, P., Colombo, E., Endeman, D., Nova, M., Laudato, L., Martino, N., Antognazza, M. R., Lanzani, G., Benfenati, F., & Ghezzi, D. (2016) · Scientific Reports · doi:10.1038/srep22718 · Cited by 97 · see citing works
Self-citationLewandowska, M., Bakkum, D. J., Rompani, S. B., & Hierlemann, A. R. (2015) · PLoS ONE · doi:10.1371/journal.pone.0118514 · Cited by 94 · see citing works
Engineering‐Aligned 3D Neural Circuit in Microfluidic Device
Bang, S., Na, S., Jang, J., Kim, J., & Jeon, N. L. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500397 · Cited by 80 · see citing works
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76 · see citing works
Self-citationLong Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75 · see citing works
Self-citationMicroengineered peripheral nerve-on-a-chip for preclinical physiological testing
Huval, R. M., Miller, O. H., Curley, J. L., Fan, Y., Hall, B. J., & Moore, M. J. (2015) · Lab on a Chip · doi:10.1039/c4lc01513d · Cited by 71 · see citing works
Chronic multichannel neural recordings from soft regenerative microchannel electrodes during gait
Musick, K. M., Rigosa, J., Narasimhan, S., Wurth, S., Capogrosso, M., Chew, D. J., Fawcett, J. W., Micera, S., & Lacour, S. P. (2015) · Scientific Reports · doi:10.1038/srep14363 · Cited by 70 · see citing works
Self-citationTracking individual action potentials throughout mammalian axonal arbors
Radivojević, M., Franke, F., Altermatt, M., Müller, J., Hierlemann, A. R., & Bakkum, D. J. (2017) · eLife · doi:10.7554/elife.30198 · Cited by 70 · see citing works
Microchannel-based regenerative scaffold for chronic peripheral nerve interfacing in amputees
Srinivasan, A., Tahilramani, M., Bentley, J. T., Gore, R. K., Millard, D. C., Mukhatyar, V. J., Joseph, A., Haque, A. S., Stanley, G. B., English, A. W., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.11.035 · Cited by 67 · see citing works
Large Extracellular Spikes Recordable From Axons in Microtunnels
Pan, L., Alagapan, S., Franca, E., et al. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2289911 · Cited by 59 · see citing works
The effect of temperature on Na currents in rat myelinated nerve fibres
Schwarz, J. R. (1986) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00590943 · Cited by 58 · see citing works
Ultrasonic stimulation of peripheral nervous tissue: an investigation into mechanisms
Wright, C. J., Rothwell, J. C., & Saffari, N. (2015) · Journal of Physics Conference Series · doi:10.1088/1742-6596/581/1/012003 · Cited by 54 · see citing works
Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff
Schuettler, M., Donaldson, N., Seetohul, V., & Taylor, J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036016 · Cited by 50 · see citing works
Noise and selectivity of velocity-selective multi-electrode nerve cuffs
Donaldson, N., Rieger, R., Schuettler, M., & Taylor, J. (2008) · Medical and Biological Engineering and Computing · doi:10.1007/s11517-008-0365-4 · Cited by 49 · see citing works
Stretch-induced nerve conduction deficits in guinea pig ex vivo nerve
Li, J., & Shi, R. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.02.009 · Cited by 47 · see citing works
Microchannel Electrodes for Recording and Stimulation: In Vitro Evaluation
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013960 · Cited by 45 · see citing works
Self-citationOptical cuff for optogenetic control of the peripheral nervous system
Michoud, F., Sottas, L., Browne, L. E., Asboth, L., Latrémolière, A., Sakuma, M., Courtine, G., Woolf, C. J., & Lacour, S. P. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9126 · Cited by 39 · see citing works
Self-citationEngineering a functional neuro-muscular junction model in a chip
Tong, Z., Seira, O., Casas, C. C., et al. (2014) · RSC Advances · doi:10.1039/c4ra10219c · Cited by 35 · see citing works
Metcalfe, B., Chew, D. J., Clarke, C. T., Donaldson, N., & Taylor, J. T. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.05.003 · Cited by 34 · see citing works
The theory of velocity selective neural recording: a study based on simulation
Taylor, J. T., Schüettler, M., Clarke, C., et al. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0874-z · Cited by 32 · see citing works
Temperature dependence of Na currents in rabbit and frog muscle membranes.
Kirsch, G. E., & Sykes, J. S. (1987) · The Journal of General Physiology · doi:10.1085/jgp.89.2.239 · Cited by 32 · see citing works
Sakai, K., Shimba, K., Kotani, K., et al. (2017) · Integrative Biology · doi:10.1039/c7ib00051k · Cited by 30 · see citing works
Subdural grid and depth electrode monitoring in pediatric patients
Skoch, J. M., Adelson, P. D., Bhatia, S., et al. (2017) · Epilepsia · doi:10.1111/epi.13685 · Cited by 28 · see citing works
NGF Uptake and Retrograde Signaling Mechanisms in Sympathetic Neurons in Compartmented Cultures
Campenot, R. B. (2009) · Results and problems in cell differentiation · doi:10.1007/400_2009_7 · Cited by 27 · see citing works
In vitro multichannel single-unit recordings of action potentials from the mouse sciatic nerve
Chen, L., Ilham, S. J., Guo, T., Emadi, S., & Feng, B. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aa7efa · Cited by 23 · see citing works
Buckley, M. M., & O’Malley, D. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00112 · Cited by 23 · see citing works
Lewandowska, M., Radivojević, M., Jäckel, D., Müller, J., & Hierlemann, A. R. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00083 · Cited by 22 · see citing works
Kuzdas-Wood, D., Irschick, R., Theurl, M., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0136575 · Cited by 21 · see citing works
Srinivasan, A., Tipton, J., Tahilramani, M., Kharbouch, A., Gaupp, E. A., Song, C. L., Venkataraman, P., Falcone, J., Lacour, S. P., Stanley, G. B., et al. (2015) · European Journal of Neuroscience · doi:10.1111/ejn.13080 · Cited by 20 · see citing works
Self-citationVelocity-Selective Recording from Frog Nerve Using a Multi-Contact Cuff Electrode
Schüettler, M., Seetohul, V., Taylor, J. T., & Donaldson, N. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260335 · Cited by 15 · see citing works
Effects of electrode size on the performance of neural recording microelectrodes
Hughes, M. P., Bustamante, K. D., Banks, D., & Ewins, D. J. (2002) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2000.893776 · Cited by 14 · see citing works
Fohlmeister, J. F. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00551.2014 · Cited by 13 · see citing works
Metcalfe, B., Chew, D. J., Clarke, C., Donaldson, N., & Taylor, J. T. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944166 · Cited by 12 · see citing works
Design Strategies for Multi-Channel Low-Noise Recording Systems
Rieger, R., Pan, Y.-Y., & Taylor, J. T. (2007) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2007.378695 · Cited by 9 · see citing works
Metcalfe, B., Chew, D. J., Clarke, C., et al. (2014) · doi:10.1109/embc.2014.6944528 · Cited by 8 · see citing works
PDMS microchannel scaffolds for neural interfaces with the peripheral nervous system
Choi, Y., Park, S., Chung, Y., et al. (2014) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/memsys.2014.6765780 · Cited by 6 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
“Their good recording properties and ease of use have, however, found use for them in ex vivo applications such as nerve-on-a-chip platforms (Gribi et al., 2018).”
BackgroundPhotovoltaic organic interface for neuronal stimulation in the near-infrared
Airaghi Leccardi, M. J. I., Chenais, N. A. L., Ferlauto, L., Kawecki, M., Zollinger, E. G., & Ghezzi, D. (2020) · Communications Materials · doi:10.1038/s43246-020-0023-4 · Cited by 63 · see citing works
Self-citation
- Authors
- Gribi, S., du Bois de Dunilac, S., Ghezzi, D., & Lacour, S. P.
- Affiliations
- École Polytechnique Fédérale de Lausanne (CH)
- Corresponding author
- Lacour, Stéphanie P.
- Venue
- Nature Communications
- Published
- 2018-10-23
- Volume
- 9
- Issue
- 1
- Pages
- 4403-4403
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC6199302
- OpenAlex
- W2896281700
- Cited by
- 72
- References
- 56
- Citations by year
- 2026: 11 · 2025: 3 · 2024: 16 · 2023: 12 · 2022: 8 · 2021: 7 · 2020: 8 · 2019: 7
- FWCI
- 2.51
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Nature Communications (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Funders
- National Science Foundation
- Fondation Bertarelli
- King's College London
- École Polytechnique Fédérale de Lausanne
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Life Sciences › Neuroscience › Cognitive Neuroscience › Undergraduate Neuroscience Education and Research
- Keywords
- peripheral nerves, nerve conduction, action potential recording, conduction velocity, myelinated axons
- MeSH terms
- Algorithms, Animals, Hot Temperature, Male, Neural Conduction, Neural Inhibition, Peripheral Nerves, Polymers, Rats, Inbred Lew, Microtechnology, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review