The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A water-soluble boronate-based fluorescent probe for the selective detection of peroxynitrite and imaging in living cells
Open accessAbstract
A water-soluble boronate-based fluorescent probe was evaluated for the detection of peroxynitrite (ONOO−) in the presence of a monosaccharide. The enhanced fluorescence of the probe when bound with D-fructose was switched off in the presence of peroxynitrite. In contrast, other reactive oxygen/nitrogen species (ROS/RNS) led to only slight fluorescence decreases due to protection by an internal N–B interaction. The interaction of the probe with D-fructose not only strengthens the fluorescence signal, but also protects the boronic acid from oxidation by other ROS/RNS. Therefore, under conditions generating various ROS/RNS, the boronate-based saccharide complex preferentially reacts with peroxynitrite. The probe was used in cell imaging experiments for the detection of endogenous and exogenous peroxynitrite. The sensor displays good “on–off” responses towards peroxynitrite, both in RAW 264.7 cells and HeLa cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peroxynitrite: biochemistry, pathophysiology and development of therapeutics
Szabó, C., Ischiropoulos, H., & Radi, R. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2222 · Cited by 2,134
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Self-citationMolecular imaging of hydrogen peroxide produced for cell signaling
Miller, E. W., Tulyathan, O., Isacoff, E. Y., & Chang, C. J. (2007) · Nature Chemical Biology · doi:10.1038/nchembio871 · Cited by 450
Neurodegenerative disorders: the role of peroxynitrite
Torreilles, F., Salman-Tabcheh, S., Guérin, M.-C., & Torreilles, J. (1999) · Brain Research Reviews · doi:10.1016/s0165-0173(99)00014-4 · Cited by 430
Cited by
Glucose Sensing in Supramolecular Chemistry
Sun, X., & James, T. D. (2015) · Chemical Reviews · doi:10.1021/cr500562m · Cited by 386
Self-citationCheng, D., Peng, J., Lv, Y., Su, D., Liu, D., Chen, M., Yuan, L., & Zhang, X. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b01374 · Cited by 308
Nitroxidative signaling mechanisms in pathological pain
Grace, P. M., Gaudet, A. D., Staikopoulos, V., Maier, S. F., Hutchinson, M. R., Salvemini, D., & Watkins, L. R. (2016) · Trends in Neurosciences · doi:10.1016/j.tins.2016.10.003 · Cited by 128
Metadata
- Authors
- Sun, X., Xu, Q., Kim, G., Flower, S. E., Lowe, J. P., Yoon, J., Fossey, J. S., Qian, X., Bull, S. D., & James, T. D.
- Venue
- Chemical Science
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014-05-23
- Volume
- 5
- Issue
- 9
- Pages
- 3368
- ISSN
- 2041-6520 (ISSN-L)
- 2041-6539
- OpenAlex
- W2150822249
- Cited by
- 218
- References
- 4
- FWCI
- 10.48
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A water-soluble boronate-based fluorescent probe for the selective detection of peroxynitrite and imaging in living cells. https://app.cochat.ai/papers/10.1039/c4sc01417k
- The paper
- Sun, X., Xu, Q., Kim, G., Flower, S. E., Lowe, J. P., Yoon, J., Fossey, J. S., Qian, X., Bull, S. D., & James, T. D. (2014). A water-soluble boronate-based fluorescent probe for the selective detection of peroxynitrite and imaging in living cells. Chemical Science. https://doi.org/10.1039/c4sc01417k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.