Liver injury-on-a-chip: microfluidic co-cultures with integrated biosensors for monitoring liver cell signaling during injury
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A microfluidic platform is used to study paracrine signaling during model liver injury. Such a microchip allows to study dynamics of paracrine crosstalk between two groups of liver cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hepatic Stellate Cells: Protean, Multifunctional, and Enigmatic Cells of the Liver
Friedman, S. L. (2008) · Physiological Reviews · doi:10.1152/physrev.00013.2007 · Cited by 2,842
Boulter, L., Govaere, O., Bird, T. G., Radulescu, S., Ramachandran, P., Pellicoro, A., Ridgway, R. A., Seo, S. S., Spee, B., Van Rooijen, N., et al. (2012) · Nature Medicine · doi:10.1038/nm.2667 · Cited by 747
TGF-β in progression of liver disease
Dooley, S., & ten Dijke, P. (2012) · Cell and Tissue Research · doi:10.1007/s00441-011-1246-y · Cited by 718
Alcoholic fatty liver: its pathogenesis and mechanism of progression to inflammation and fibrosis
Lieber, C. S. (2004) · Alcohol · doi:10.1016/j.alcohol.2004.07.008 · Cited by 699
Cited by
Organ-on-a-chip: recent breakthroughs and future prospects
Wu, Q., Liu, J., Wang, X., Feng, L., Wu, J., Zhu, X., Wen, W., & Gong, X. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-0752-0 · Cited by 701
Multiorgan-on-a-Chip: A Systemic Approach To Model and Decipher Inter-Organ Communication
Picollet-D’hahan, N., Zuchowska, A., Lemeunier, I., & Le Gac, S. (2021) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.11.014 · Cited by 379
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
A critical perspective on 3D liver models for drug metabolism and toxicology studies
Serras, A. S., Rodrigues, J. S., Cipriano, M., Rodrigues, A. V., Oliveira, N. G., & Miranda, J. P. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.626805 · Cited by 138
Simulating drug concentrations in PDMS microfluidic organ chips
Grant, J., Özkan, A., Oh, C., Mahajan, G., Prantil-Baun, R., & Ingber, D. E. (2021) · Lab on a Chip · doi:10.1039/d1lc00348h · Cited by 133
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
“The same group developed another cell-culture/biosensor platform with the same device, using the similar sensing approach for detection of TGF-β1 from activated stellate cells (Figure 6C) (109).”
BackgroundMethodInfluentialEngineered Liver Platforms for Different Phases of Drug Development
Ware, B. R., & Khetani, S. R. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.08.001 · Cited by 90
“Finally, other groups have developed microfluidic devices with incorporated antibody-based biosensors for monitoring transforming growth factor (TGF)-β1, an activator of HSCs [58,59].”
BackgroundInfluentialBridging the gap: microfluidic devices for short and long distance cell–cell communication
Vu, T. Q., de Castro, R. M. B., & Qin, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01367h · Cited by 63
Soucy, J. R., Bindas, A. J., Koppes, A. N., & Koppes, R. A. (2019) · iScience · doi:10.1016/j.isci.2019.10.052 · Cited by 62
Bioartificial livers: a review of their design and manufacture
Tuerxun, K., He, J., Ibrahim, I., Yusupu, Z., Yasheng, A., Xu, Q., Tang, R., Aikebaier, A., Wu, Y., Tuerdi, M., et al. (2022) · Biofabrication · doi:10.1088/1758-5090/ac6e86 · Cited by 24
“Cellular components in liver tissue microenvironments can also be reproduced and rearranged by co-culturing parenchymal hepatocytes and non-parenchymal cells, such as endothelial cells [153], stellate cells [154], and Kupffer cells [155], in the form of sheets [149] or spheroids [156].”
Dufva, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-35043-5 · Cited by 14
Metadata
- Authors
- Zhou, Q., Patel, D., Kwa, T., Haque, A., Matharu, Z., Stybayeva, G., Gao, Y., Diehl, A. M., & Revzin, A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 15
- Issue
- 23
- Pages
- 4467-4478
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2117934122
- Cited by
- 138
- References
- 4
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.