The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Beating heart on a chip: a novel microfluidic platform to generate functional 3D cardiac microtissues
Abstract
The beating heart-on-a-chip (i) generates 3D cardiac constructs with well-defined geometries from cell-laden hydrogel prepolymers, (ii) provides uniaxial cyclic mechanical stimulation, (iii) allows efficient delivery of drugs and chemicals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Single-step method of RNA isolation by acid guanidinium thiocyanate-phenol-chloroform extraction
Chomczynski, P., & Sacchi, N. (1987) · Analytical Biochemistry · doi:10.1016/0003-2697(87)90021-2 · Cited by 46,426
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Tissue Engineering of a Differentiated Cardiac Muscle Construct
Zimmermann, W.-H., Schneiderbanger, K., Schubert, P., Didié, M., Münzel, F., Heubach, J. F., Kostin, S., Neuhuber, W. L., & Eschenhagen, T. (2002) · Circulation Research · doi:10.1161/hh0202.103644 · Cited by 917
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
Wang, G., McCain, M. L., Yang, L., He, A., Pasqualini, F. S., Agarwal, A., Yuan, H., Jiang, D., Zhang, D., Zangi, L., et al. (2014) · Nature Medicine · doi:10.1038/nm.3545 · Cited by 837
Universal physical responses to stretch in the living cell
Trepat, X., Deng, L., An, S. S., Navajas, D., Tschumperlin, D. J., Gerthoffer, W. T., Butler, J. P., & Fredberg, J. J. (2007) · Nature · doi:10.1038/nature05824 · Cited by 699
Electrical stimulation systems for cardiac tissue engineering
Tandon, N., Cannizzaro, C., Chao, P.-H. G., Maidhof, R., Marsano, A., Au, H. T. H., Radisic, M., & Vunjak-Novakovic, G. (2009) · Nature Protocols · doi:10.1038/nprot.2008.183 · Cited by 528
Self-citationHuman iPSC-based Cardiac Microphysiological System For Drug Screening Applications
Mathur, A., Loskill, P., Shao, K., Huebsch, N., Hong, S., Marcus, S. G., Marks, N., Mandegar, M., Conklin, B. R., Lee, L. P., et al. (2015) · Scientific Reports · doi:10.1038/srep08883 · Cited by 519
Microfluidic heart on a chip for higher throughput pharmacological studies
Agarwal, A., Goss, J. A., Cho, A., McCain, M. L., & Parker, K. K. (2013) · Lab on a Chip · doi:10.1039/c3lc50350j · Cited by 494
Boudou, T., Legant, W. R., Mu, A., Borochin, M. A., Thavandiran, N., Radisic, M., Zandstra, P. W., Epstein, J. A., Margulies, K. B., & Chen, C. S. (2012) · Tissue Engineering Part A · doi:10.1089/ten.tea.2011.0341 · Cited by 413
Engineering microscale cellular niches for three-dimensional multicellular co-cultures
Huang, C. P., Lu, J., Seon, H., Lee, A. P., Flanagan, L. A., Kim, H.-Y., Putnam, A. J., & Jeon, N. L. (2009) · Lab on a Chip · doi:10.1039/b818401a · Cited by 384
Human engineered heart tissue as a versatile tool in basic research and preclinical toxicology
Schaaf, S., Shibamiya, A., Mewe, M., Eder, A., Stöhr, A., Hirt, M. N., Rau, T., Zimmermann, W.-H., Conradi, L., Eschenhagen, T., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026397 · Cited by 365
Thickness-dependent mechanical properties of polydimethylsiloxane membranes
Liu, M., Sun, J., Sun, Y., Bock, C., & Chen, Q. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/3/035028 · Cited by 351
Huebsch, N., Loskill, P., Mandegar, M. A., Marks, N. C., Sheehan, A. S., Ma, Z., Mathur, A., Nguyen, T. N., Yoo, J. C., Judge, L. M., et al. (2015) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2014.0283 · Cited by 313
Design and formulation of functional pluripotent stem cell-derived cardiac microtissues
Thavandiran, N., Dubois, N., Mikryukov, A., Massé, S., Beca, B., Simmons, C. A., Deshpande, V. S., McGarry, J. P., Chen, C. S., Nanthakumar, K., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1311120110 · Cited by 285
Cardiac tissue engineering using perfusion bioreactor systems
Radisic, M., Marsano, A., Maidhof, R., Wang, Y., & Vunjak-Novakovic, G. (2008) · Nature Protocols · doi:10.1038/nprot.2008.40 · Cited by 273
Self-citationAn actuated pump on-chip powered by cultured cardiomyocytes
Tanaka, Y., Morishima, K., Shimizu, T., Kikuchi, A., Yamato, M., Okano, T., & Kitamori, T. (2006) · Lab on a Chip · doi:10.1039/b515149j · Cited by 211
Pulsatile Stretch Remodels Cell-to-Cell Communication in Cultured Myocytes
Zhuang, J., Yamada, K. A., Saffitz, J. E., & Kléber, A. G. (2000) · Circulation Research · doi:10.1161/01.res.87.4.316 · Cited by 204
From cardiac tissue engineering to heart-on-a-chip: beating challenges
Zhang, Y. S., Aleman, J., Arneri, A., Bersini, S., Piraino, F., Shin, S. R., Dokmeci, M. R., & Khademhosseini, A. (2015) · Biomedical Materials · doi:10.1088/1748-6041/10/3/034006 · Cited by 189
Advancing functional engineered cardiac tissues toward a preclinical model of human myocardium
Turnbull, I. C., Karakikes, I., Serrao, G. W., Backeris, P., Lee, J., Xie, C., Senyei, G., Gordon, R. E., Li, R. A., Akar, F. G., et al. (2014) · The FASEB Journal · doi:10.1096/fj.13-228007 · Cited by 184
Salameh, A., Wustmann, A., Karl, S., Blanke, K., Apel, D., Rojas-Gomez, D., Franke, H., Mohr, F. W., Janousek, J., & Dhein, S. (2010) · Circulation Research · doi:10.1161/circresaha.109.214429 · Cited by 170
Controlled electromechanical cell stimulation on-a-chip
Pavesi, A., Adriani, G., Rasponi, M., Zervantonakis, I. K., Fiore, G. B., & Kamm, R. D. (2015) · Scientific Reports · doi:10.1038/srep11800 · Cited by 119
Self-citationValve-based microfluidic compression platform: single axon injury and regrowth
Hosmane, S., Fournier, A. J., Wright, R. M., Rajbhandari, L., Siddique, R., Yang, I. H., Ramesh, K. T., Venkatesan, A., & Thakor, N. V. (2011) · Lab on a Chip · doi:10.1039/c1lc20549h · Cited by 100
Jonsson, M. K. B., Wang, Q., & Becker, B. (2011) · Assay and Drug Development Technologies · doi:10.1089/adt.2011.0396 · Cited by 94
van den Heuvel, N. H. L., van Veen, T. A. B., Lim, B., & Jonsson, M. K. B. (2013) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2013.12.011 · Cited by 88
Chen, H., Cornwell, J. A., Zhang, H., Lim, T., Resurreccion, R., Port, T., Rosengarten, G., & Nordon, R. E. (2013) · Lab on a Chip · doi:10.1039/c3lc50123j · Cited by 80
Engineered approaches to the stem cell microenvironment for cardiac tissue regeneration
Ghafar‐Zadeh, E., Waldeisen, J. R., & Lee, L. P. (2011) · Lab on a Chip · doi:10.1039/c1lc20284g · Cited by 78
Marsano, A., Maidhof, R., Wan, L. Q., Wang, Y., Gao, J., Tandon, N. M., & Vunjak‐Novakovic, G. (2010) · Biotechnology Progress · doi:10.1002/btpr.435 · Cited by 77
Self-citationUgolini, G. S., Rasponi, M., Pavesi, A., Santoro, R., Kamm, R. D., Fiore, G. B., Pesce, M., & Soncini, M. (2015) · Biotechnology and Bioengineering · doi:10.1002/bit.25847 · Cited by 59
Self-citationKurazumi, H., Kubo, M., Ohshima, M., Yamamoto, Y., Takemoto, Y., Suzuki, R., Ikenaga, S., Mikamo, A., Udo, K., Hamano, K., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0028890 · Cited by 57
Microsystems for biomimetic stimulation of cardiac cells
Simmons, C. S., Petzold, B. C., & Pruitt, B. L. (2012) · Lab on a Chip · doi:10.1039/c2lc40308k · Cited by 52
Bioengineering heart tissue for in vitro testing
Cimetta, E., Godier-Furnémont, A., & Vunjak‐Novakovic, G. (2013) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.07.002 · Cited by 33
Cited by
Organs-on-chips: into the next decade
Low, L. A., Mummery, C., Berridge, B. R., Austin, C. P., & Tagle, D. A. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0079-3 · Cited by 1,029
Bioprinting 3D microfibrous scaffolds for engineering endothelialized myocardium and heart-on-a-chip
Zhang, Y. S., Arneri, A., Bersini, S., Shin, S.-R., Zhu, K., Goli-Malekabadi, Z., Aleman, J., Colosi, C., Busignani, F., Dell'Erba, V., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.09.003 · Cited by 951
Self-citationOrgan-on-a-chip: recent breakthroughs and future prospects
Wu, Q., Liu, J., Wang, X., Feng, L., Wu, J., Zhu, X., Wen, W., & Gong, X. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-0752-0 · Cited by 701
Organs-on-a-Chip: A Fast Track for Engineered Human Tissues in Drug Development
Ronaldson-Bouchard, K., & Vunjak-Novakovic, G. (2018) · Cell Stem Cell · doi:10.1016/j.stem.2018.02.011 · Cited by 657
Organ-on-a-Chip: A New Paradigm for Drug Development
Ma, C., Peng, Y., Li, H., & Chen, W. (2021) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2020.11.009 · Cited by 576
Metadata
- Authors
- Marsano, A., Conficconi, C., Lemme, M., Occhetta, P., Gaudiello, E., Votta, E., Cerino, G., Redaelli, A., & Rasponi, M.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2016
- Volume
- 16
- Issue
- 3
- Pages
- 599-610
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2213652914
- Cited by
- 447
- References
- 35
- FWCI
- 11.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.