Organs-on-Chips with combined multi-electrode array and transepithelial electrical resistance measurement capabilities
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Combined integration of TEER and MEA sensors in a single endothelialized Organ-on-Chip platform.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The epithelial monolayer formed in this device could be probed from both the apical and basal sides of the epithelium, and this enabled quantification of tight junction barrier function31, 32 and absorption of nutrients33 and drugs.30, 34”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [32]
Citations
Cites
Fiji: an open-source platform for biological-image analysis
Schindelin, J., Arganda-Carreras, I., Frise, E., Kaynig, V., Longair, M., Pietzsch, T., Preibisch, S., Rueden, C., Saalfeld, S., Schmid, B., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2019 · Cited by 66,890
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationBhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Self-citationTEER Measurement Techniques for In Vitro Barrier Model Systems
Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J. (2015) · SLAS Technology · doi:10.1177/2211068214561025 · Cited by 2,145
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Instrumented cardiac microphysiological devices via multimaterial three-dimensional printing
Lind, J. U., Busbee, T. A., Valentine, A. D., Pasqualini, F. S., Yuan, H., Yadid, M., Park, S.-J., Kotikian, A., Nesmith, A. P., Campbell, P. H., et al. (2017) · Nature Materials · doi:10.1038/nmat4782 · Cited by 863
Self-citationCharacterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
Griep, L. M., Wolbers, F., de Wagenaar, B., ter Braak, P. M., Weksler, B. B., Romero, I. A., Couraud, P. O., Vermes, I., van der Meer, A. D., & van den Berg, A. (2013) · Biomedical Microdevices · doi:10.1007/s10544-012-9699-7 · Cited by 537
The role of tumor necrosis factor in the pathophysiology of heart failure
Feldman, A. M., Combes, A., Wagner, D., Kadakomi, T., Kubota, T., You Li, Y., & McTiernan, C. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00600-2 · Cited by 506
Research works printed but not linked: 2
- Kim, 2015, Proc. Natl. Acad. Sci. U. S. A., 113, 201522193
- Dewi, 2004, Methods, 121, 171
Cited by
Items 101–200 of 272
Heart-on-a-chip systems: disease modeling and drug screening applications
Butler, D., & Reyes, D. R. (2024) · Lab on a Chip · doi:10.1039/d3lc00829k · Cited by 47
Scalable Fabrication of Stretchable, Dual Channel, Microfluidic Organ Chips
Novak, R., Didier, M., Calamari, E. L., Ng, C. F., Choe, Y., Clauson, S. L., Nestor, B., Puerta, J., Fleming, R. C., Jalili‐Firoozinezhad, S., et al. (2018) · Journal of Visualized Experiments · doi:10.3791/58151 · Cited by 47
Self-citationChapin, A. A., Rajasekaran, P. R., Quan, D. N., Hu, L., Herberholz, J., Bentley, W. E., & Ghodssi, R. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-00184-4 · Cited by 43
Organ-on-a-chip with integrated semitransparent organic electrodes for barrier function monitoring
Marrero, D., Guimerà‐Brunet, A., Maes, L., Villa, R., Álvarez, M., & Illa, X. (2023) · Lab on a Chip · doi:10.1039/d2lc01097f · Cited by 41
Shanmugam, D. K., Anitha, S., Souresh, V., Madhavan, Y., Sampath, S., Venugopal, D. C., & Saravanan, M. (2023) · Materials Technology · doi:10.1080/10667857.2023.2242732 · Cited by 46
“In comparison to other methods mentioned, this can modify human reactions such that they can be effectively mimicked in the laboratory [27].”
ResultWhat Can an Organ-on-a-Chip Teach Us About Human Lung Pathophysiology?
Bai, H., & Ingber, D. E. (2022) · Physiology · doi:10.1152/physiol.00012.2022 · Cited by 42
Self-citationSpatial trans-epithelial electrical resistance (S-TEER) integrated in organs-on-chips
Renous, N., Kiri, M. D., Barnea, A. R., Rauti, R., Leichtmann‐Bardoogo, Y., & Maoz, B. M. (2021) · Lab on a Chip · doi:10.1039/d1lc00789k · Cited by 41
Self-citationChapron, A., Chapron, B. D., Hailey, D. W., Chang, S., Imaoka, T., Thummel, K. E., Kelly, E. J., Himmelfarb, J., Shen, D. D., & Yeung, C. K. (2020) · ACS Pharmacology & Translational Science · doi:10.1021/acsptsci.9b00078 · Cited by 40
Advancements in modelling human blood brain-barrier on a chip
Guarino, V., Zizzari, A. T., Bianco, M., Gigli, G., Moroni, L., & Arima, V. (2023) · Biofabrication · doi:10.1088/1758-5090/acb571 · Cited by 39
“Indeed, OoCs were found to be more effective in predicting human response than the traditional in vitro cell cultures and in vivo methods of animal testing and, therefore, to be efficient in preclinical predictions [78].”
BackgroundIntegrating mechanical sensor readouts into organ-on-a-chip platforms
Anaya, I., Boghdady, C.-M., Campbell, B. E., & Moraes, C. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.1060895 · Cited by 40
“to integrate both MEA and TEER electrodes on a heart-on-a-chip platform, permitting real-time measurement of electrical activity across the cardiomyocyte cultures (Maoz et al., 2017).”
BackgroundZhang, F., Cheng, H., Qu, K.-Y., Qian, X., Lin, Y., Zhang, Y., Qian, S.-C., Huang, N., Cui, C., & Chen, M. (2023) · Materials Today Bio · doi:10.1016/j.mtbio.2023.100626 · Cited by 53
Advances in the Model Structure of In Vitro Vascularized Organ-on-a-Chip
Yin, H., Wang, Y., Liu, N., Zhong, S., Li, L., Zhang, Q., Liu, Z., & Yue, T. (2024) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0107 · Cited by 43
“[114] integrated a vertical dual-channel chip (Fig.”
Sorption of Neuropsychopharmaca in Microfluidic Materials for In Vitro Studies
Winkler, T. E., & Herland, A. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c07639 · Cited by 38
Self-citationRecapitulating essential pathophysiological characteristics in lung-on-a-chip for disease studies
Zhang, Y., Wang, X., Yang, Y. L., Yan, J., Xiong, Y., Wang, W., Lei, J., & Jiang, T. (2023) · Frontiers in Immunology · doi:10.3389/fimmu.2023.1093460 · Cited by 40
“Oxygen, temperature, and lung disease biomarker sensors also measure the physical parameters of the lung-on-a-chip (69, 70).”
BackgroundEngineering cardiac microphysiological systems to model pathological extracellular matrix remodeling
Ariyasinghe, N. R., Lyra‐Leite, D. M., & McCain, M. L. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00110.2018 · Cited by 40
“The endothelial cell layer was used to regulate drug transport to the underlying cardiac myocytes, which more closely recapitulates the relationship between these cells in vivo (112).”
MethodTang, Y., Tian, F., Miao, X., Wu, D., Wang, Y., Wang, H., You, K., Li, Q., Zhao, S., & Wang, W. (2022) · Biofabrication · doi:10.1088/1758-5090/ac975d · Cited by 39
“Maoz et al [23] reported firstly a heart-on-a-chip system with an integrated endothelial layer based on a commercial polyethylene terephthalate (PET) membrane, and their results preliminarily showed the influence of the endothelial layer on the effect of isoproterenol (ISP) on CMs.”
InfluentialIn situ biosensing technologies for an organ-on-a-chip
Kim, J., Kim, J., Jin, Y., & Cho, S. (2023) · Biofabrication · doi:10.1088/1758-5090/aceaae · Cited by 36
“Since multi-organ systems generate many signals, it might be difficult to detect and quantify all the signals via single sensing technology [90, 91].”
Low, L. A., Sutherland, M. L., Lumelsky, N. L., Selimović, Š., Lundberg, M. S., & Tagle, D. A. (2020) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-36588-2_3 · Cited by 37
Gholizadeh, H., Ong, H. X., Bradbury, P., Kourmatzis, A., Traini, D., Young, P. M., Li, M., & Cheng, S. (2021) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2021.1873274 · Cited by 34
“ferent microfluidic and electrode designs to facilitate the quantification of epithelial and endothelial barrier functions in microfluidic devices such as blood-brain-barrier-on-chip [16], pulmonary epithelium on-chip, gut-on-a-chip [17,18], and heart-on-a-chip [19].”
BackgroundMicrofluidic platforms for monitoring cardiomyocyte electromechanical activity
Wang, W., Su, W., Han, J., Song, W., Li, X., Xu, C., Sun, Y., & Wang, L. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00751-z · Cited by 33
“For example, endothelialized heart-on-a-chips were created by integrating MEAs and electrodes for epithelial resistance measurements into a micro fl uidic chip 98 .”
Challenges in Permeability Assessment for Oral Drug Product Development
Koziolek, M., Augustijns, P., Berger, C., Cristofoletti, R., Dahlgren, D., Keemink, J., Matsson, P., McCartney, F., Metzger, M., Mezler, M., et al. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15102397 · Cited by 34
“Membrane integrity is often evaluated using transepithelial electrical resistance (TEER) [56,59] or paracellular permeability measurements with fluorescently labeled dextran [53,56,60].”
BackgroundMalik, M., Steele, S. A., Mitra, D., Long, C. J., & Hickman, J. J. (2025) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2025.100588 · Cited by 43
Ugodnikov, A., Persson, H., & Simmons, C. A. (2024) · Lab on a Chip · doi:10.1039/d3lc01027a · Cited by 32
Integration of biological systems with electronic-mechanical assemblies
Yi, N., Cui, H., Zhang, L. G., & Cheng, H. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.04.032 · Cited by 33
Transforming a well into a chip: A modular 3D-printed microfluidic chip
Rauti, R., Ess, A., Roi, B. L., Kreinin, Y., Epshtein, M., Korin, N., & Maoz, B. M. (2021) · APL Bioengineering · doi:10.1063/5.0039366 · Cited by 29
Self-citationGuttenplan, A. P. M., Birgani, Z. N. T., Giselbrecht, S., Truckenmüller, R. K., & Habibović, P. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100371 · Cited by 34
Park, S. M., Eom, S., Hong, H., Yoon, J., Lee, S. J., Kim, B. C., Kim, H. W., & Kim, D. S. (2018) · Microelectronic Engineering · doi:10.1016/j.mee.2018.10.010 · Cited by 31
Engineering Neurovascular Unit and Blood–Brain Barrier for Ischemic Stroke Modeling
Liu, Z., Tang, Y., Zhang, Z., Liu, Q., Wang, M., Li, W., & Yang, G. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202202638 · Cited by 30
Mainardi, A., Cambria, E., Occhetta, P., Martín, I., Barbero, A., Schären, S., Mehrkens, A., & Krupkova, O. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.826867 · Cited by 29
Organ-on-a-Chip: Ubi sumus? Fundamentals and Design Aspects
Morais, A. S., Mendes, M., Cordeiro, M. A., Sousa, J., Pais, A. A. C. C., Mihaila, S. M., & Vitorino, C. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16050615 · Cited by 26
“Initially, OoaC incorporated different analysis techniques, such as the enzyme im-munoabsorption assay (ELISA), electrical transepithelial resistance (TEER), and multiple electrode matrices (MEA) [45–47].”
MethodToward continuous monitoring systems: emerging trends of on-chip sensors in organ-on-a-chip
Ling, S., Xu, C., Jiang, Y., Xu, F., Jin, H., Chen, H. H., Chen, S., Ding, Z., & Sun, D. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-01142-8 · Cited by 29
“In cardiac tissue models, treatment with the in fl ammatory cytokine TNF-α led to endothelial barrier damage, with TEER dropping from 230 ± 45 Ω to 15 ± 13 Ω , fl uorescence microscopy further con fi rmed severe barrier disruption 141 .”
Imaging therapeutic peptide transport across intestinal barriers
Larsen, J. B., Taebnia, N., Dolatshahi‐Pirouz, A., Eriksen, A. Z., Hjørringgaard, C. U., Kristensen, K., Larsen, N. W., Larsen, N. B., Marie, R., Mündler, A.-K., et al. (2021) · RSC Chemical Biology · doi:10.1039/d1cb00024a · Cited by 27
da Silva, G. G., Sacomani, D. P., de Carvalho, B. G., Porcionatto, M. A., Gobbi, Â. L., Lima, R. S., & de la Torre, L. G. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c02221 · Cited by 26
Oyunbaatar, N., Shanmugasundaram, A., Jeong, Y., Lee, B.-K., Kim, E., & Lee, D. (2019) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2019.110682 · Cited by 25
Emerging Biosensor Trends in Organ-on-a-Chip
Rothbauer, M., & Ertl, P. (2020) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2020_129 · Cited by 26
Membrane-based microfluidic systems for medical and biological applications
Calzuola, S. T., Newman, G., Feaugas, T., Perrault, C. M., Blondé, J.-B., Roy, E., Porrini, C., Stojanović, G. M., & Vidić, J. (2024) · Lab on a Chip · doi:10.1039/d4lc00251b · Cited by 24
“Despite their importance, these aspects are often neglected in OOC in which membranes are typically obtained from commercial Transwell inserts 66 – 75 or filter membranes 76 – 84 .”
Yuan, S., Yuan, H., Hay, D. C., Hu, H., & Wang, C. (2024) · Biosensors · doi:10.3390/bios14090425 · Cited by 26
“Different methods are used for detecting pH and oxygen levels [27].”
MethodBlood brain barrier-on-a-chip to model neurological diseases
Reshma, S. C., Megha, K. B., Amir, S., Rukhiya, S., & Mohanan, P. V. (2023) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2023.104174 · Cited by 24
Badiola-Mateos, M., Giuseppe, D. D., Paoli, R., Lopez-Martinez, M. J., Mencattini, A., Samitier, J., & Martinelli, E. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.129599 · Cited by 24
Building blocks of microphysiological system to model physiology and pathophysiology of human heart
Vuorenpää, H., Björninen, M., Välimäki, H., Ahola, A., Kroon, M., Honkamäki, L., Koivumäki, J. T., & Pekkanen-Mattila, M. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1213959 · Cited by 24
“In studies involving characterization of diseases in heart-on-chip models and the need for understanding electromechanical coupling, electrical measurements and/or calcium imaging has been included, with MEAs being a typically used means of electrical measurement (Mathur et al., 2015; Ellis et al., 2017; Maoz et al.,…”
MethodDeir, S., Mofrad, Y. M., Mashayekhan, S., Shamloo, A., & Mansoori-Kermani, A. (2023) · Talanta · doi:10.1016/j.talanta.2023.124901 · Cited by 25
Trends in organ-on-a-chip for pharmacological analysis
Xu, X., Cheung, S., Jia, X., Fan, G., Ai, Y., Zhang, Y., & Liang, Q. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117905 · Cited by 24
A layered cancer-on-a-chip system for anticancer drug screening and disease modeling
Flont, M., Dybko, A., & Jastrzębska, E. (2023) · The Analyst · doi:10.1039/d3an00959a · Cited by 21
Strategies for directing cells into building functional hearts and parts
Jafarkhani, M., Salehi, Z., Kowsari‐Esfahan, R., Shokrgozar, M. A., Mohammadi, M. R., Rajadas, J., & Mozafari, M. (2018) · Biomaterials Science · doi:10.1039/c7bm01176h · Cited by 20
Sivakumar, R., Trinh, K. T. L., & Lee, N. Y. (2020) · RSC Advances · doi:10.1039/d0ra02332a · Cited by 20
New Endeavors of (Micro)Tissue Engineering: Cells Tissues Organs on-Chip and Communication Thereof
Ahmed, H. M. M., & Teixeira, L. M. (2021) · Cells Tissues Organs · doi:10.1159/000516356 · Cited by 19
Organ-on-a-chip and 3D printing as preclinical models for medical research and practice
Jain, A., Mathur, T., Pandian, N. K. R., & Selahi, A. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-819178-1.00009-5 · Cited by 25
Lung on a Chip Development from Off-Stoichiometry Thiol–Ene Polymer
Rimša, R., Galvanovskis, A., Plūme, J., Rūmnieks, F., Grindulis, K., Paidere, G., Erentraute, S., Mozoļevskis, G., & Ābols, A. (2021) · Micromachines · doi:10.3390/mi12050546 · Cited by 19
“In both processes, the temperature limiting factor is membrane material used in OOC devices [68].”
BackgroundBuilding Biomimetic Potency Tests for Islet Transplantation
Glieberman, A. L., Pope, B. D., Melton, D. A., & Parker, K. K. (2021) · Diabetes · doi:10.2337/db20-0297 · Cited by 19
Self-citationSpitz, S., Schobesberger, S., Brandauer, K., & Ertl, P. (2023) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10604 · Cited by 20
“49 Overall, while planar MEAs can be readily integrated into OoC platforms, they are primarily suitable for 2D applications as close proximity between electroactive cells and electrodes is required for effective use.”
BackgroundMethodNew bioimaging avenues for organs‐on‐chips by integration of bioluminescence
Teixeira, L. M., & Mezzanotte, L. (2021) · View · doi:10.1002/viw.20200177 · Cited by 17
Building Blood Vessel Chips with Enhanced Physiological Relevance
Mu, X., Gerhard‐Herman, M. D., & Zhang, Y. S. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201778 · Cited by 16
Modelling Neuromuscular Diseases in the Age of Precision Medicine
Speciale, A. A., Ellerington, R., Goedert, T., & Rinaldi, C. (2020) · Journal of Personalized Medicine · doi:10.3390/jpm10040178 · Cited by 17
“Organ on chips have been adapted for the human gut [52], heart [53], blood–brain barrier [54], and kidney [55].”
BackgroundEar-Bot: Locust Ear-on-a-Chip Bio-Hybrid Platform
Fishel, I., Amit, Y., Shvil, N., Sheinin, A., Ayali, A., Yovel, Y., & Maoz, B. M. (2021) · Sensors · doi:10.3390/s21010228 · Cited by 16
“Moreover, in order to tackle the above-mentioned challenges, we used recent developments in micro-physiological systems (MPS), also known as Organs-on-a-Chip (OoC) [22,23] in order to create a modular tissue support, and a custom algorithm for signal analysis.”
MethodSelf-citationNasiri, R., Madadelahi, M., Nikmaneshi, M. R., Gökçe, B., Bijarchi, M. A., Shah, S., Tirpáková, Z., Gastel, D. V., Taebnia, N., de Barros, N. R., et al. (2025) · Biomaterials · doi:10.1016/j.biomaterials.2025.123739 · Cited by 19
Self-citationChebotarev, O., Ugodnikov, A., & Simmons, C. A. (2024) · ACS Applied Bio Materials · doi:10.1021/acsabm.4c00114 · Cited by 15
Kawakita, S., Li, S., Nguyen, H. T., Maity, S., Haghniaz, R., Bahari, J., Yu, N., Mandal, K., Bandaru, P., Mou, L., et al. (2023) · Biomedical Microdevices · doi:10.1007/s10544-023-00669-9 · Cited by 15
Bax, M., Thorpe, J., & Romanov, V. (2023) · Frontiers in Sensors · doi:10.3389/fsens.2023.1294721 · Cited by 19
Ramírez-González, G. A., Consumi-Tubito, C., Vargas-Méndez, E., & Centeno-Cerdas, C. (2025) · Polymers · doi:10.3390/polym17091263 · Cited by 14
“Aor et al. (2020) made a chip consisting of multiple layers of chitosan and hyaluronic acid over polycarbonate, on top of which HUVECs were seeded [127].”
Bossink, E. G. B. M., Vollertsen, A. R., Loessberg-Zahl, J., van der Meer, A. D., Segerink, L. I., & Odijk, M. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00378-y · Cited by 15
Body-on-a-Chip: Regenerative Medicine for Personalized Medicine
Skardal, A., Shupe, T. D., & Atala, A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-809880-6.00044-8 · Cited by 17
Digital Twins in Smart Manufacturing
Aziz, S., Jung, D. W., Zaman, U. K. U., & Aqeel, A. B. (2023) · CRC Press eBooks · doi:10.1201/9781003327523-6 · Cited by 15
Microfluidic devices in tissue engineering
Bahrami, S., Baheiraei, N., Najafi-Ashtiani, M., Nour, S., & Razavi, M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818791-3.00008-5 · Cited by 16
The Exciting Realities and Possibilities of iPS-Derived Cardiomyocytes
Takahashi, F., Patel, P., Kitsuka, T., & Arai, K. (2023) · Bioengineering · doi:10.3390/bioengineering10020237 · Cited by 13
“Introducing capillary permeability to heart-on-a-chip models has been challenging, with only preliminary findings exhibiting successful recreation of a permeable endotheliumlined vascular layer [104,106].”
BackgroundComplex or not too complex? One size does not fit all in next generation microphysiological systems
Bersini, S., Arrigoni, C., Talò, G., Candrian, C., & Moretti, M. (2024) · iScience · doi:10.1016/j.isci.2024.109199 · Cited by 14
“…simplified systems based on 2.5D cell cultures embedded within microfluidic devices (e.g., hydrogel matrices surrounded by monolayers of endothelial cells 12–14 ), the scientific community has been developing increasingly complex 3D, multi-culture models reproducing organ-specific microenvironments.”
BackgroundKing, O., Sunyovszki, I., & Terracciano, C. M. (2021) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-021-02557-8 · Cited by 13
“An example of this is simultaneous observation of EC barrier function (via trans-endothelial electrical resistance (TEER) measurement) and myocardial conduction velocity (via multi-electrode array (MEA)) [112].”
BackgroundProgress and Challenges in the Use of a Liver-on-a-Chip for Hepatotropic Infectious Diseases
Kulkeaw, K., & Pengsart, W. (2021) · Micromachines · doi:10.3390/mi12070842 · Cited by 13
“combined a dual biosensing system consisting of multielectrode arrays (MEAs) and electrodes for transepithelial electrical resistance (TEER) to measure the electrical activity of cardiomyocytes and ionic conductance between the paracellular space, respectively [94] (Figure 2B).”
BackgroundThe promise of Synovial Joint-on-a-Chip in rheumatoid arthritis
Zhang, X., Su, R., Wang, H., Wu, R., Fan, Y., Bin, Z., Gao, C., & Wang, C. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1408501 · Cited by 13
The Role of Silicon Technology in Organ‐On‐Chip: Current Status and Future Perspective
Skottvoll, F. S., Escobedo‐Cousin, E., & Mielnik, M. M. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202401254 · Cited by 13
Recent Advances in Integrated Organ‐Chip Sensing Toward Robust and User‐Friendly Systems
Schellberg, B. G., Koppes, R. A., & Koppes, A. N. (2025) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37876 · Cited by 16
Glial cells influence cardiac permittivity as evidenced through in vitro and in silico models
Soucy, J. R., Askaryan, J., Díaz, D. D., Koppes, A. N., Annabi, N., & Koppes, R. A. (2019) · Biofabrication · doi:10.1088/1758-5090/ab4c0a · Cited by 13
“As further validation, μTissues were treated with isoproterenol, a beta-adrenergic agonist to demonstrate the utility of this algorithm to detect a changes in physiological responses (Maoz et al 2017).”
MethodYip, J. K., Sarkar, D., Petersen, A. P., Gipson, J. N., Tao, J., Kale, S., Rexius‐Hall, M. L., Cho, N., Khalil, N. N., Kapadia, R., et al. (2021) · Lab on a Chip · doi:10.1039/d0lc00948b · Cited by 13
Electrochemical Imaging of Endothelial Permeability Using a Large-Scale Integration-Based Device
Ino, K., Pai, H.-J., Hiramoto, K., Utagawa, Y., Nashimoto, Y., & Shiku, H. (2021) · ACS Omega · doi:10.1021/acsomega.1c04931 · Cited by 13
Microphysiological stem cell models of the human heart
Arslan, U., Moruzzi, A., Nowacka‐Woszuk, J., Mummery, C. L., Eckardt, D., Loskill, P., & Orlova, V. V. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100259 · Cited by 12
“Adopting a similar strategy, self-rolling biosensor arrays which wraps around the 3D microtissue/organoid [124], or microelectrodes integrated in EHT and HoC platforms allow continuous and multiplexed recording of electrophysiological signals [88,121,125].”
BackgroundMethodLow-Impedance PEDOT:PSS MEA Integrated in a Stretchable Organ-on-Chip Device
Waafi, A. K., Gaio, N., Quirós-Solano, W. F., Dijkstra, P., Sarro, P. M., & Dekker, R. H. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2946854 · Cited by 12
“Previous work has addressed this issue by combining commercially available MEAs with soft-lithography based microfluidic channels [8]–[10].”
Das, P., van der Meer, A. D., Vivas, A., Arık, Y. B., Remigy, J., Lahitte, J., Lammertink, R. G. H., & Bacchin, P. (2019) · Tissue Engineering Part A · doi:10.1089/ten.tea.2019.0021 · Cited by 12
Dehne, E., & Marx, U. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00013-9 · Cited by 14
Miyazaki, T., Hirai, Y., Kamei, K., Tsuchiya, T., & Tabata, O. (2020) · Electronics and Communications in Japan · doi:10.1002/ecj.12296 · Cited by 11
Modeling the Response of Heart Muscle to Mechanical Stimulation In Vitro
Guo, J., & Huebsch, N. (2020) · Current Tissue Microenvironment Reports · doi:10.1007/s43152-020-00007-8 · Cited by 12
Non-contact monitoring of extra-cellular field potentials with a multi-electrode array
Sharf, T., Hansma, P. K., Hari, M. A., & Kosik, K. S. (2019) · Lab on a Chip · doi:10.1039/c8lc00984h · Cited by 13
Ultrapliable bioelectronic interface for mechanosensitive cardiac electrophysiology
Yu, J., Jiang, Z., Ackers-Johnson, M. A., Zou, G., Zhang, F., Zhu, M., Cao, C., Li, J., Vidyasekar, P., Li, W., et al. (2026) · Science Advances · doi:10.1126/sciadv.adz1253 · Cited by 12
Ugodnikov, A., Chebotarev, O., Persson, H., & Simmons, C. A. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.3c01898 · Cited by 10
In vitro electrochemical assays for vascular cells and organs
Utagawa, Y., Hiramoto, K., Nashimoto, Y., Ino, K., & Shiku, H. (2021) · Electrochemical Science Advances · doi:10.1002/elsa.202100089 · Cited by 10
Xiang, X., Wang, X., Shang, Y., & Ding, Y. (2023) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2023.03.006 · Cited by 11
Truong, N., Zahra, A., Lintao, R. C. V., Chauhan, R., Bento, G. F. C., Vidal, M. S., Kim, S., Lam, P. Y., Conrads, T. P., Conrads, K. A., et al. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1568389 · Cited by 10
Naquin, T. D., Naquin, C. M., Qian, W. U., Chen, Y., Canning, A. J., Yang, K., Li, Y., Zhao, S., Ling, Y., Ma, Z., et al. (2026) · Lab on a Chip · doi:10.1039/d5lc00957j · Cited by 10
Ferguson, C. A., Pini, N., Du, X., Farina, M., Hwang, J. C. M., Pietrangelo, T., & Cheng, X. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338678 · Cited by 10
Gholizadeh, H., Cheng, S., Kourmatzis, A., Xing, H., Traini, D., Young, P. M., & Ong, H. X. (2022) · Bioengineering · doi:10.3390/bioengineering9040150 · Cited by 11
Advancing Tumor Microenvironment Research by Combining Organs-on-Chips and Biosensors
Calejo, I., Heinrich, M. A., Zambito, G., Mezzanotte, L., Prakash, J., & Teixeira, L. M. (2022) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-04039-9_7 · Cited by 9
Microbiota‐gut‐brain axis multi‐organ chip construction and applications in drug evaluation
Tang, Y., Chen, H., Zhao, Z., Kang, X., Wang, W., Dai, K., Guo, Y., Liang, A., Luo, A., & Hao, Z. (2025) · iMetaOmics. · doi:10.1002/imo2.70065 · Cited by 11
“…flow and pressure under multi ‐ channel conditions [15, 158], real ‐ time monitoring and multi ‐ omics analysis of complex signals in chip [159, 160], and functional integration of organ modules — ensuring physiological positioning, connectivity, and activity — requires further optimization…”
Takata, Y., Sadeghian, R. B., Fujimoto, K., & Yokokawa, R. (2024) · The Analyst · doi:10.1039/d4an00267a · Cited by 8
Rahav, N., Marrero, D., Soffer, A., Glickman, E., Beldjilali‐Labro, M., Yaffe, Y., Tadmor, K., Leichtmann‐Bardoogo, Y., Ashery, U., & Maoz, B. M. (2024) · Advanced Science · doi:10.1002/advs.202305555 · Cited by 7
Self-citationLi, Y., Xu, M., Zhu, Z., Xu, F., & Chen, B. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1236610 · Cited by 7
“Generally, TEER detection chips comprise two layers of microfluidic chambers that are separated by a porous membrane for cellular barrier formation (Douville et al., 2010; Ferrell et al., 2010;Maoz et al., 2017; Wei et al., 2023).”
BackgroundMethodPannexin1 Channel-Mediated Inflammation in Acute Ischemic Stroke
Huang, Y., Shi, Y., Wang, M., Liu, B., Chang, X., Xiao, X., Yu, H., Cui, X., & Bai, Y. (2023) · Aging and Disease · doi:10.14336/ad.2023.0303 · Cited by 13
“This technology could be leveraged to monitor the current changes associated with the PANX1 channel on nerve cells to analyze its activity [137].”
BackgroundState of the Art in Integrated Biosensors for Organ-on-a-Chip Applications
Dey, T., Mitra, P., Chakraborty, B., Sanyal, A., Acharjee, A., Ghosh, A., & Mandal, D. (2024) · Smart nanomaterials technology · doi:10.1007/978-981-99-6597-7_10 · Cited by 9
Shukla, S., Comerci, C. J., Süel, G. M., & Jahed, Z. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116843 · Cited by 7
Angelovski, A., & Bébarová, M. (2025) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2025.07.005 · Cited by 6
Shi, Y., Sun, S., Liu, H., Zhao, M., Qin, M., Liu, J., Hu, J., Zhao, Y., Li, M., Zhang, L., et al. (2024) · Lab on a Chip · doi:10.1039/d4lc00817k · Cited by 6
Recent technological advances in lab-on-a-chip for bone remodeling
Kim, S., Rajendran, A. K., Amirthalingam, S., Kim, J. H., So, K., & Hwang, N. S.-Y. (2023) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2023.100360 · Cited by 11
Transendothelial electrical resistance (TEER) measurement system of 3D tubular vascular channel
Mori, N., Morimoto, Y., & Takeuchi, S. (2018) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2018.8346551 · Cited by 7
Metadata
- Authors
- Maoz, B. M., Herland, A., Henry, O. Y. F., Leineweber, W. D., Yadid, M., Doyle, J., Mannix, R., Kujala, V. J., FitzGerald, E. A., Parker, K. K., & Ingber, D. E.
- Affiliations
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Ingber, Donald E.
- ORCID
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2017
- Volume
- 17
- Issue
- 13
- Pages
- 2294-2302
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2621877040
- Cited by
- 266
- References
- 36
- Citations by year
- 2026: 24 · 2025: 20 · 2024: 32 · 2023: 32 · 2022: 21 · 2021: 47 · 2020: 38 · 2019: 23 · 2018: 26 · 2017: 3
- FWCI
- 11.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Defense Advanced Research Projects Agency (W911NF-12-2-0036)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- organ-on-a-chip, microelectrode arrays, transepithelial electrical resistance, integrated sensing, heart-on-a-chip, human cardiomyocytes, human endothelial cells, vascular permeability, TNF-α, isoproterenol, microfluidic cell culture, real-time monitoring
- MeSH terms
- Cell Line, Electrodes, Equipment Design, Humans, Electric Impedance, Cell Culture Techniques, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices, Human Umbilical Vein Endothelial Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.