Organs-on-Chips with combined multi-electrode array and transepithelial electrical resistance measurement capabilities
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Combined integration of TEER and MEA sensors in a single endothelialized Organ-on-Chip platform.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The epithelial monolayer formed in this device could be probed from both the apical and basal sides of the epithelium, and this enabled quantification of tight junction barrier function31, 32 and absorption of nutrients33 and drugs.30, 34”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [32]
Citations
Cites
Fiji: an open-source platform for biological-image analysis
Schindelin, J., Arganda-Carreras, I., Frise, E., Kaynig, V., Longair, M., Pietzsch, T., Preibisch, S., Rueden, C., Saalfeld, S., Schmid, B., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2019 · Cited by 66,890
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationBhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Self-citationTEER Measurement Techniques for In Vitro Barrier Model Systems
Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J. (2015) · SLAS Technology · doi:10.1177/2211068214561025 · Cited by 2,145
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Instrumented cardiac microphysiological devices via multimaterial three-dimensional printing
Lind, J. U., Busbee, T. A., Valentine, A. D., Pasqualini, F. S., Yuan, H., Yadid, M., Park, S.-J., Kotikian, A., Nesmith, A. P., Campbell, P. H., et al. (2017) · Nature Materials · doi:10.1038/nmat4782 · Cited by 863
Self-citationCharacterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
Griep, L. M., Wolbers, F., de Wagenaar, B., ter Braak, P. M., Weksler, B. B., Romero, I. A., Couraud, P. O., Vermes, I., van der Meer, A. D., & van den Berg, A. (2013) · Biomedical Microdevices · doi:10.1007/s10544-012-9699-7 · Cited by 537
The role of tumor necrosis factor in the pathophysiology of heart failure
Feldman, A. M., Combes, A., Wagner, D., Kadakomi, T., Kubota, T., You Li, Y., & McTiernan, C. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00600-2 · Cited by 506
Research works printed but not linked: 2
- Kim, 2015, Proc. Natl. Acad. Sci. U. S. A., 113, 201522193
- Dewi, 2004, Methods, 121, 171
Cited by
Items 201–272 of 272
Casanova, A., Alimohammadzadeh, E., McCormirk, S., Thomas, Y. R. J., den Dulk, R., Baldi, A., Fernández‐Sánchez, C., Ghaemmaghami, A. M., & Mailley, P. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118981 · Cited by 6
Engineered in vitro models: mimicking in vivo physiology
Shah, L., & Tirella, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823966-7.00002-5 · Cited by 5
Automation and opportunities for industry scale-up of microphysiological systems
Dehne, E., Erfurth, H., Muhsmann, A.-K., & Marx, U. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00014-0 · Cited by 6
Construction, evaluation, and applications of renal barrier-on-a-chip system
Naren, T., Lv, W., Aazmi, A., Wang, Y., Yu, H., Lee, J. Y., Yang, H., Yu, M., Jiang, X., Yang, H., et al. (2026) · Bioactive Materials · doi:10.1016/j.bioactmat.2025.12.032 · Cited by 4
“It is dynamically measured in real-time using integrated microelectrodes in OoCs, providing continuous data on barrier stability over days or weeks [267,268].”
Mares, A. G., Feiner‐Gracia, N., Muela, Y., Martínez, G., Delgado, L., Albertazzi, L., & Pujals, S. (2021) · Applied Nano · doi:10.3390/applnano2040021 · Cited by 4
“TEER is used to measure the integrity of the epithelial barrier, and has been applied to gut- and lung-ona-chip models, to reveal the viability of the systems, as well as barrier disruptions [5,30].”
MethodBató, L., Fürjes, P., Bozorádi, J. M., Tadić, V., Odry, P., & Vizvári, Z. (2025) · Sensors · doi:10.3390/s25206393 · Cited by 3
“In OoC models, TEER has been applied to study the blood–brain barrier [15], the lung [16], the gut [17], and the skin [18], among many others.”
Ogawa, T., Yamatake, R., Kanno, Y., Nisisako, T., Hunge, Y. M., Ino, K., Liu, S., Li, C.-Z., Yoshinobu, T., Shiku, H., et al. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118414 · Cited by 3
Hu, W., & Lv, X. (2025) · International Journal of Electrochemical Science · doi:10.1016/j.ijoes.2025.101178 · Cited by 3
Emerging strategies in 3D printed tissue models for in vitro biomedical research
Pless, C. J., Radeke, C., Cakal, S. D., Kajtez, J., Pasqualini, F. S., & Lind, J. U. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-85430-6.00007-8 · Cited by 3
Cytocentric measurement for regenerative medicine
Henn, A. D., Pereira, T., Hunsberger, J. G., Mitra, K., Izadifar, Z., Somara, S., Lindström, L., Farb-Horch, T. F., Boy, J., Muschler, G. F., et al. (2023) · Frontiers in Medical Technology · doi:10.3389/fmedt.2023.1154653 · Cited by 3
Sade, O., Boneberg, R., Weiss, Y., Beldjilali‐Labro, M., Leichtmann‐Bardoogo, Y., Talpir, I., Gottfried, I., Ashery, U., Rauti, R., & Maoz, B. M. (2023) · Biomedical Optics Express · doi:10.1364/boe.498038 · Cited by 3
Self-citationRogal, J., Zamproni, L. N., Nikolakopoulou, P., Ygberg, S. E., Wedell, A., Wredenberg, A., & Herland, A. (2024) · Stem Cells Translational Medicine · doi:10.1093/stcltm/szae021 · Cited by 3
Self-citationChen, Y., Wang, Z., Liu, Q., Zhao, M., Ye, H., Zheng, Z., Tang, R., Wang, Y., Pan, T., Zhang, X., et al. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136999 · Cited by 2
Dubourg, G., Prabhakaran, D., Dawson, H., Radonić, V., Joksović, S., Stanojev, J., & Homs-Corbera, A. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116413 · Cited by 2
Advances in sensor integration for real-time monitoring of joint-on-chips
Mantegazza, A., Materne, S., Rasponi, M., & Occhetta, P. (2026) · Biophysics Reviews · doi:10.1063/5.0287852 · Cited by 2
Artificial intelligence-augmented organ- and organoid-on-a-chip for drug screening
Song, C., Li, T., Guan, H., Zhang, T., Zhu, J., Lei, J., Dong, F., Liu, C., Song, Z., & Huang, L. (2026) · Lab on a Chip · doi:10.1039/d6lc00365f · Cited by 3
Gut‐on‐chip with integrated sensors: Enables in‐situ monitoring and real‐time evaluation of the chip
Li, Y., Xiang, Z., Yuan, Z., Zhang, H., & Shi, A. (2024) · Electroanalysis · doi:10.1002/elan.202400188 · Cited by 2
Netala, V. R., Hou, T., & Zhang, Z. (2025) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2025.107171 · Cited by 4
Microfabrication of Embedding a Flexible Parylene-Based Microelectrode Array within Body-on-a-Chip
Omaki, T., Hirai, Y., Kamei, K., Tsuchiya, T., & Tabata, O. (2017) · EUROSENSORS Conference (EUROSENSORS) · doi:10.3390/proceedings1040302 · Cited by 2
“This is because real-time read-out of in vitro systems can provide temporally resolved high-content information on pharmacodynamic drug responses, compared to the dead cell assay [3].”
BackgroundMiyazaki, T., Hirai, Y., Kamei, K., Tsuchiya, T., & Tabata, O. (2020) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.140.285 · Cited by 2
“Lung-on-a-chip” as an instrument for studying the pathophysiology of human respiration
Zhukova, O. A., Ozerskaya, I. V., Basmanov, D. V., Stolyarov, V. Y., Bogush, V. G., Kolesov, V. V., Zykov, K. A., Yusubalieva, G. M., & Baklaushev, V. P. (2024) · Journal of clinical practice · doi:10.17816/clinpract637140 · Cited by 1
“Однако интегральная регистрация TEER в микрофлюидном устройстве имеет свои ограничения, поскольку даже небольшой участок нарушения целостности клеток значительно снижает общее TEER, несмо-тря на наличие плотного монослоя на всех осталь-ных участках [91].”
Recent advances of microfluidic organ-on-a-chip monitoring strategies
Ebrahimi, A., Benzait, Z., Tomsuk, Ö., Özel, C., Tüfekçioğlu, E., Dordinejad, G. G., Didarian, R., Ghorbanpoor, H., Güzel, F. D., & Avcı, H. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-21519-3.00029-7 · Cited by 3
Comprehending the Membrane Properties for Emulation in Organs‐on‐a‐Chip
Sathe, T., & Bodas, D. (2025) · Advanced NanoBiomed Research · doi:10.1002/anbr.202500078 · Cited by 1
Tadevosyan, K., Yeste, J., Álvarez, M., Marrero, D., Casado-Medina, L., Richaud‐Patín, Y., Iglesias‐García, O., Litowczenko, J., Morillas-García, A., Guimerà‐Brunet, A., et al. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.202505524 · Cited by 3
“ISO responses aligned with prior reports of β -agonist effects [10, 14, 25, 46, 51], though unlike other studies [52, 53], we observed no EC-mediated attenuation of CM contractility.”
Engineering Organ-on-a-Chip Systems for Cancer Immunotherapy: Strategies and Assay Integration
Wang, J., & Wang, Z. (2026) · Bioengineering · doi:10.3390/bioengineering13050492 · Cited by 1
Emerging Regenerative Medicine for Spinal Cord Injury: Spinal Cord Organoids-on-a-Chip
Khan, M., Choi, H., Ahmad, S., Lee, S., Park, J., & Han, I. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27157060 · Cited by 1
Yip, J. K., & McCain, M. L. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813671-3.00008-6 · Cited by 1
Body-on-a-chip: three-dimensional engineered tissue models
Shupe, T. D., Skardal, A., & Atala, A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818422-6.00078-2 · Cited by 1
Advances in Micro-Bioreactor Design for Organ Cell Studies
Mandenius, C. (2018) · MDPI eBooks · doi:10.3390/books978-3-03897-232-7 · Cited by 1
Novel, Emerging Chip Models of the Blood-Brain Barrier and Future Directions
Holloway, P. M. (2022) · Methods in molecular biology · doi:10.1007/978-1-0716-2289-6_11 · Cited by 1
Organs-on-chips for the pharmaceutical development process: design perspectives and implementations
Christoffersson, J. (2018) · doi:10.3384/diss.diva-145300 · Cited by 3
“the beating properties of cardiomyocytes [124] or neuronal network activity [125], or by measuring the transendothelial- or transepithelial electrical resistance (TEER) over monolayers of cells [110,126].”
BackgroundChoi, G., Kim, K., Yang, H.-Y., Cho, S., Park, S.-A., Kwon, D., Cho, S.-H., Yoon, S., Kang, H., Lee, J.-H., et al. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.09.16.676208 · Cited by 2
Development of thermoplastic elastomer microfluidic systems for bio-applications
Thomée, E. (2021) · theses.fr (ABES) · doi:10.70675/d170ecfcz37b1z4139z9400z0af73d6097ea · Cited by 2
Microfluidic Platforms for Biofabrication and 3D Tissue Modeling
Nie, M., & Takeuchi, S. (2019) · Royal Society of Chemistry eBooks · doi:10.1039/9781788012683-00049
Das, P. (2018) · theses.fr (ABES) · doi:10.3990/1.159058878
Estimation de position par des techniques d’impédancemétrie : applications aux puces microfluidiques
Brazey, B. (2019) · theses.fr (ABES) · doi:10.70675/d1703b3cz14c5z49c2zac66z6b0f67f4066b
A method for rapid generation of model intestinal barriers in vitro
Nikulin, S. V., Poloznikov, A. A., & Sakharov, D. A. (2020) · Вестник Российского государственного медицинского университета · doi:10.24075/vrgmu.2020.077
Organ-on-a-chip Applications using Collagen Tubular Constructs
Chow, K. (2020) · TSpace (University of Toronto)
Internship and Monograph reports entitled”Organ-on-a-chip: current status and future prospects"
Morais, A. S. (2021) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Glial Cells in the Heart? Replicating the Diversity of the Myocardium with Low-Cost 3D ModelsPreprint
Soucy, J. R., Askaryan, J., Díaz, D. D., Koppes, A. N., Annabi, N., & Koppes, R. A. (2018) · SSRN Electronic Journal · doi:10.2139/ssrn.3205400
Falcón‐Banchs, R. (2020) · eScholarship (California Digital Library)
The artificial gut : integrating in vitro models of the human digestive tract with mass spectrometry
Santbergen, M. J. C. (2020) · doi:10.18174/532696
Measurement and analytical techniques
Grochala, D., Paleczek, A., López‐Muñoz, G. A., & Rydosz, A. M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15384-6.00003-3
Multiorgans-on-a-chip for subacute toxicity
Chiome, T. J., M.V.S.S.T., S. R., & Srinivasan, A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-13782-2.00021-8
Baranowska, P., Flont, M., Żuchowska, A., Brzózka, Z., & Jastrzębska, E. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15978-7.00048-5
Emerging technologies for the integration of flexible electronics into Heart-on-a-Chip platforms
Choo, J. (2025) · Journal of High School Science · doi:10.64336/001c.142193
Kefallinou, D. (2024) · DSpace - NTUA (National Technical University of Athens) · doi:10.26240/heal.ntua.26483
Reconstructing the cardiac conduction system in vitro
Devalla, H. D. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-24142-0.00012-6
Experimental and computational methods for monitoring of dynamic arterial cellular organization
Chashchiná, O. (2020) · theses.fr (ABES) · doi:10.70675/8e1eab05z6fb7z467bza238z406981a36fcd
Interdigitated ITO sensor for ECIS monitoring of breast cancer cells
Santamaria, J. A. M. (2019) · theses.fr (ABES) · doi:10.70675/bde3946dza818z434bz8dd6z7374dc3a47a7
Scalable microfluidic blood oxygenator with compliant membrane for improved performance
Calzuola, S. T. (2024) · theses.fr (ABES) · doi:10.70675/ba5166b4ze915z4b43zb98fz2b278bb6ee65
Monchablon, M. (2023) · theses.fr (ABES) · doi:10.70675/1674d15ez05eaz4b9ezb932z6d4cd7d64426
Delaney, W. H., Faulkner, S. A., Lam, W. A., Boulis, N. M., Qiu, Y., & Lei, K. (2026) · Materials Today Advances · doi:10.1016/j.mtadv.2026.100770
“MEAs are grids of microscale electrodes that can detect field potentials or action potentials from cells [123].”
Intelligent organ-on-chip platforms: Machine learning in predictive and personalized drug delivery
Khurana, T., Ganguly, S., & Kiran Raj, M. (2026) · Biomicrofluidics · doi:10.1063/5.0306883
Jiang, S., Wu, S., Ye, S., Sun, J., Bai, H., Zhang, Y. S., Xie, X., & Li, Y. (2026) · Journal of Future Foods · doi:10.1016/j.jfutfo.2026.05.011
Hernández-Castro, J. A., Lussier, F., Malic, L., Geißler, M., Kim, T.-H., Moon, B., Li, K., Zhao, Y., Clime, L., Brassard, D., et al. (2026) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2026.115945
Li, J., Xin, J., Qu, L., Xu, L., Huang, Y., Gu, Z., Qi, L., & Wang, Z. (2026) · Biofabrication · doi:10.1088/1758-5090/ae9ef3
“These systems facilitate in situ and synchronous acquisition of parameters such as pH, oxygen concentration, electrochemical signals, and cellular morphology, thereby enabling the dynamic and continuous tracking of complex in vitro physiological processes [9, 10].”
Advanced Techniques in Metal Neurotoxicity
Jimoh-Abdulghaffaar, H. O., Rabiu, S. O., & Amidu, S. B. (2026) · IGI Global eBooks · doi:10.4018/979-8-2600-1403-5.ch014
Николаевич, К. А., Krasnoselskaya, E. N., Khanova, A. R., & Николаевич, Ф. С. (2026) · Biomaterials Advances · doi:10.1016/j.bioadv.2026.215141
Organ-on-a-chip platforms for disease modeling and in vitro diagnostic applications
Hao, P., Jingrong, D., & Xu, J. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1956618
“Bone marrow-on-a-chip systems with vascularized niches have sustained CD34 + hematopoietic stem/ (Stucki et al., 2015; Maoz et al., 2017; Henry et al., 2017; Cao et al., 2022; Thacker et al., 2020) Liver HepaRG/HepG2 hepatocytes; hiPSC-derived hepatocytes; HUVECs Electrochemical (O 2 ), fluorescent…”
Steger-Polt, M.-H., Thomas, Y. R. J., Pham, P., & Mailley, P. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119274
Steger-Polt, M.-H., Pham, P., Mandula, O., Mailley, P., & Thomas, Y. R. J. (2026) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2026.109474
Design and engineering of multiorgan systems
Shupe, T. D., Campbell, J., & Atala, A. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-16110-0.00010-8
The concept of organ-on-a-chip and body-on-a-chip devices
Zhang, Y. S., & Atala, A. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-16110-0.00014-5
Microfabrication techniques for making organ-on-a-chip and body-on-a-chip devices
Azizgolshani, H., & Borenstein, J. T. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-16110-0.00021-2
Morais, A. S. A. S. (2020) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Ramos, S. M. D. M. (2017) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Organoids as Building Blocks for Adaptive and Resilient Biohybrid Robots
Georgopoulou, A. (2026) · Advanced Materials Technologies · doi:10.1002/admt.71449
Metadata
- Authors
- Maoz, B. M., Herland, A., Henry, O. Y. F., Leineweber, W. D., Yadid, M., Doyle, J., Mannix, R., Kujala, V. J., FitzGerald, E. A., Parker, K. K., & Ingber, D. E.
- Affiliations
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Ingber, Donald E.
- ORCID
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2017
- Volume
- 17
- Issue
- 13
- Pages
- 2294-2302
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2621877040
- Cited by
- 266
- References
- 36
- Citations by year
- 2026: 24 · 2025: 20 · 2024: 32 · 2023: 32 · 2022: 21 · 2021: 47 · 2020: 38 · 2019: 23 · 2018: 26 · 2017: 3
- FWCI
- 11.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Defense Advanced Research Projects Agency (W911NF-12-2-0036)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- organ-on-a-chip, microelectrode arrays, transepithelial electrical resistance, integrated sensing, heart-on-a-chip, human cardiomyocytes, human endothelial cells, vascular permeability, TNF-α, isoproterenol, microfluidic cell culture, real-time monitoring
- MeSH terms
- Cell Line, Electrodes, Equipment Design, Humans, Electric Impedance, Cell Culture Techniques, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices, Human Umbilical Vein Endothelial Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.