CoChat

Quantification of protein glycation using vibrational spectroscopy

Open access

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

FTIR-ATR and Raman spectroscopy can distinguish between glycated and non-glycated proteins.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c9an02318f

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Reaction scheme showing the general process of glycation in proteins.
Fig. 1 Reaction scheme showing the general process of glycation in proteins.CC-BY · From the PDF
Fig. 2 (a) FTIR-ATR spectrum showing the controls (samples incubated with no glucose labelled S and glycated lysozyme G from incubation day 1 through until day 30. Spectra are cut to only show between 1800 cm -1 to 700 cm -1 , b) PCA scores plot carried out across full spectra (400 -4000 cm -1 ) and (c) the corresponding PCA loadings plot. Samples were fi ltered, bu ff er exchanged to H2O and stored at -20 °C until the analysis was undertaken. The FTIR was carried on solid samples at 25 °C using the parameters stated in the methods. All FTIR data is an average of 5 replicates per sample. The data were scaled to allow a more accurate comparison between the samples as described in ESI (Data pre-processing and chemometrics † ). TEV = total explained variance.
Fig. 2 (a) FTIR-ATR spectrum showing the controls (samples incubated with no glucose labelled S and glycated lysozyme G from incubation day 1 through until day 30. Spectra are cut to only show between 1800 cm -1 to 700 cm -1 , b) PCA scores plot carried out across full spectra (400 -4000 cm -1 ) and (c) the corresponding PCA loadings plot. Samples were fi ltered, bu ff er exchanged to H2O and stored at -20 °C until the analysis was undertaken. The FTIR was carried on solid samples at 25 °C using the parameters stated in the methods. All FTIR data is an average of 5 replicates per sample. The data were scaled to allow a more accurate comparison between the samples as described in ESI (Data pre-processing and chemometrics † ). TEV = total explained variance.CC-BY · From the PDF
Fig. 3 FTIR-ATR spectra of control lysozyme (S30) after 30 days of incubation with no glucose; glycated lysozyme after 30 day (G30); and lysozyme mixed with free glucose. Samples are lyophilized and analysed under the same conditions to compare bound and free glucose peaks.
Fig. 3 FTIR-ATR spectra of control lysozyme (S30) after 30 days of incubation with no glucose; glycated lysozyme after 30 day (G30); and lysozyme mixed with free glucose. Samples are lyophilized and analysed under the same conditions to compare bound and free glucose peaks.CC-BY · From the PDF
Fig. 4 Raman spectra and PCA of glycation concentration with 9%, 78% and 94% glycated sample outliers removed. (a) Pre-processed Raman spectra with three repeats per sample, (b) PCA scores plot of samples excluding outliers showing PC 1 has a total explained variance (TEV) of 63% and PC 3 has a TEV of 10%, and (c) the corresponding loadings plot to highlight peaks that contributed to the separation of samples in the PCA.
Fig. 4 Raman spectra and PCA of glycation concentration with 9%, 78% and 94% glycated sample outliers removed. (a) Pre-processed Raman spectra with three repeats per sample, (b) PCA scores plot of samples excluding outliers showing PC 1 has a total explained variance (TEV) of 63% and PC 3 has a TEV of 10%, and (c) the corresponding loadings plot to highlight peaks that contributed to the separation of samples in the PCA.CC-BY · From the PDF
Fig. 5 Raman spectra of lysozyme and albumin all shown as an average of three replicates. (a) and (d) show lysozyme and albumin at 12 mg mL -1 in 25 mM MOPS and 115 mM NaCl at pH 7.4 glycated, control and with 10 mg mL -1 glucose added. (b) and (e) PCA scores plots of the albumin and lysozyme samples showing the three separate replicates per condition. (c) and (e) show the corresponding PCA loadings plot for lysozyme and albumin. Both loadings plots highlight peaks at 1040 cm -1 as being signi fi cant to the separation in PC 2.
Fig. 5 Raman spectra of lysozyme and albumin all shown as an average of three replicates. (a) and (d) show lysozyme and albumin at 12 mg mL -1 in 25 mM MOPS and 115 mM NaCl at pH 7.4 glycated, control and with 10 mg mL -1 glucose added. (b) and (e) PCA scores plots of the albumin and lysozyme samples showing the three separate replicates per condition. (c) and (e) show the corresponding PCA loadings plot for lysozyme and albumin. Both loadings plots highlight peaks at 1040 cm -1 as being signi fi cant to the separation in PC 2.CC-BY · From the PDF
Fig. 6 PLSR linear predictive model of % glycation of lysozyme from 0 to 100% in ∼ 6% increments totaling 16 concentrations. The model was built on 8 data sets each with three spectral repeats. The model was tested on the remaining 8 data sets. The model test set had a Q 2 p of 0.97 and an RMSEp of 5.53%.
Fig. 6 PLSR linear predictive model of % glycation of lysozyme from 0 to 100% in ∼ 6% increments totaling 16 concentrations. The model was built on 8 data sets each with three spectral repeats. The model was tested on the remaining 8 data sets. The model test set had a Q 2 p of 0.97 and an RMSEp of 5.53%.CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 4

  1. L. C. Maillard, C. R. Hebd. Seances Acad. Sci., 1912, 154, 66-68.
  2. J. M. Berg, J. L. Tymoczko, L. Stryer and L. Stryer, Biochemistry, W.H. Freeman, New York, 5th edn, 2002.
  3. ICH, ICH Topic Q 6 B Specifications: Test Procedures and Acceptance Criteria for Biotechnological/Biological Products, 1999.
  4. C. Quan, E. Alcala, I. Petkovska, D. Matthews, E. Canova-Davis, R. Taticek and S. Ma, Anal. Biochem., 2008, 373, 179-191. · DOI · Paper page

Cited by

See all 35

Metadata

Authors
McAvan, B. S., France, A. P., Bellina, B., Barran, P. E., Goodacre, R., & Doig, A. J.
Affiliations
  • University of Manchester (GB)
  • University of Liverpool (GB)
Corresponding author
Doig, Andrew J.
Venue
The Analyst
Published
2020
Volume
145
Issue
10
Pages
3686-3696
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W3000764852
Cited by
35
References
32
Citations by year
2026: 11 · 2025: 9 · 2024: 6 · 2023: 3 · 2022: 3 · 2021: 2 · 2020: 1
FWCI
1.07
Type
journal article
Language
en
Open access
Locations
  • The Analyst (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Research Explorer (The University of Manchester) (publishedVersion, cc-by)
Funders
Biotechnology and Biological Sciences Research Council (BB/L014734/1, BB/L014823/1)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Advanced Glycation End Products research
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
Keywords
protein glycation, glycated proteins, Raman spectroscopy, high-throughput quantification, disease diagnosis, vibrational spectroscopy
MeSH terms
Albumins, Glycosylation, Humans, Muramidase, Spectrum Analysis, Raman, Vibration, Spectroscopy, Fourier Transform Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.