CoChat

Hydrogels as artificial matrices for cell seeding in microfluidic devices

Open access

The DOI matches its Crossref record; 146 of the 146 references it cites were found in a registry or an index.

Abstract

Hydrogel-based artificial scaffolds and its incorporation with microfluidic devices play a vital role in shifting in vitro models from two-dimensional (2D) cell culture to in vivo like three-dimensional (3D) cell culture

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/d0ra08566a

Cites

146 of 146 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Structural similarities between extracellular matrix (ECM) and hydrogels. (A) ECM is consisted of three groups of macromolecules: structural proteins (collagens), proteoglycans, and glycoproteins (fibronectin) to form the matrix for cell attachment. Proteoglycan and structural fibrous proteins fill the cells' interstitial space to provide the mechanical and biological supports. Hydrogel scaffold from (B) natural polymers and (C) synthetic polymers. Fibrous hydrogel polymers link by interconnected microscopic pores to provide mechanical and biological cellular support.
Fig. 1 Structural similarities between extracellular matrix (ECM) and hydrogels. (A) ECM is consisted of three groups of macromolecules: structural proteins (collagens), proteoglycans, and glycoproteins (fibronectin) to form the matrix for cell attachment. Proteoglycan and structural fibrous proteins fill the cells' interstitial space to provide the mechanical and biological supports. Hydrogel scaffold from (B) natural polymers and (C) synthetic polymers. Fibrous hydrogel polymers link by interconnected microscopic pores to provide mechanical and biological cellular support.CC BY · PubMed Central
Fig. 2 Hydrogel based artificial scaffold for cell culture. (A) Scaffold, composed of natural polymers, provides the cellular support by enabling the cells to bind with a variety of different integrin-binding sites and growth factor and regulates cell behaviour through activating signalling cascade. (B) Scaffold, composed of synthetic polymers, lacks growth factors and integrin binding sites that only provides the mechanical support for cell growth.
Fig. 2 Hydrogel based artificial scaffold for cell culture. (A) Scaffold, composed of natural polymers, provides the cellular support by enabling the cells to bind with a variety of different integrin-binding sites and growth factor and regulates cell behaviour through activating signalling cascade. (B) Scaffold, composed of synthetic polymers, lacks growth factors and integrin binding sites that only provides the mechanical support for cell growth.CC BY · PubMed Central
Fig. 3 Schematic illustration of synthesis of hydrogel by physical methods (A–C) and chemical method (D).
Fig. 3 Schematic illustration of synthesis of hydrogel by physical methods (A–C) and chemical method (D).CC BY · PubMed Central
Fig. 4 Stimuli-responsive hydrogels. (A) Thermoresponsive sol–gel transition of gelatin. (B) pH-sensitive swelling–deswelling behaviour of acidic and basic hydrogels redrew from Kocak et al.42 (D) Influence of applied electric filed on hydrogel reconstructed from Qureshi et al.43 (C) Photosensitivity in the sol–gel transition of azobenzene-based hydrogel redrew from Zhao et al.41
Fig. 4 Stimuli-responsive hydrogels. (A) Thermoresponsive sol–gel transition of gelatin. (B) pH-sensitive swelling–deswelling behaviour of acidic and basic hydrogels redrew from Kocak et al.42 (D) Influence of applied electric filed on hydrogel reconstructed from Qureshi et al.43 (C) Photosensitivity in the sol–gel transition of azobenzene-based hydrogel redrew from Zhao et al.41CC BY · PubMed Central
Fig. 5 Characteristic attributes of 2D and 3D microfluidic cell culture systems. (A) Characteristics of the conventional 2D cell culture system. (B) A commonly used microfluidic 3D cell culture model and cellular orientation in the gel compartment.
Fig. 5 Characteristic attributes of 2D and 3D microfluidic cell culture systems. (A) Characteristics of the conventional 2D cell culture system. (B) A commonly used microfluidic 3D cell culture model and cellular orientation in the gel compartment.CC BY · PubMed Central
Fig. 6 Reconstructed schematic diagrams of 3D microfluidic cell culture devices. (A) Isometric view of the hydrogel patterns with a zoomed in illustration (B) of the capillary barriers, PDMS pillars and hydrogel compartments of the compartmentalized model,73 (C) TEM (the tumour microenvironment) model,74 and (D) vascular model.75
Fig. 6 Reconstructed schematic diagrams of 3D microfluidic cell culture devices. (A) Isometric view of the hydrogel patterns with a zoomed in illustration (B) of the capillary barriers, PDMS pillars and hydrogel compartments of the compartmentalized model,73 (C) TEM (the tumour microenvironment) model,74 and (D) vascular model.75CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 146 references

Research works printed but not linked: 11

  1. Kapałczyńska, 2018, Arch. Med. Sci., 14, 910
  2. He, 2014, J. Mater. Sci.: Mater. Med., 25, 2491
  3. Almeida, 2012, J. Appl. Pharm. Sci., 2, 1
  4. Nikolova, 2019, Bioact. Mater. Med., 4, 271
  5. Rosser, 2015, J. Cell Biol. Cell Metab., 2, 40569161
  6. Chen, 2011, BioMEMS Biomed. Nanotechnol., 13, 753
  7. van Hennik, 1987, Cancer Res., 47, 6297
  8. Van Duinen, 2019, J. Visualized Exp., 31762444
  9. Li, 2012, Bioanalysis, 4, 1509, 10.4155/bio.12.133 · DOI · Paper page
  10. Ahn, 2019, Front. Bioeng. Biotechnol., 7, 31380359
  11. Cambria, 2020, Front. Bioeng. Biotechnol., 8, 32373605

Cited by

Items 101–128 of 128

Metadata

Authors
Akther, F., Little, P., Li, Z., Nguyen, N.-T., & Ta, H. T.
Affiliations
  • Griffith University (AU)
  • The University of Queensland (AU)
  • Queensland University of Technology (AU)
Corresponding author
Ta, Hang T.
Venue
RSC Advances
Published
2020
Volume
10
Issue
71
Pages
43682-43703
ISSN
2046-2069 (ISSN-L)
OpenAlex
W3110903371
Cited by
127
References
146
Citations by year
2026: 15 · 2025: 26 · 2024: 29 · 2023: 24 · 2022: 22 · 2021: 11
FWCI
1.02
Type
journal article
Language
en
Open access
Locations
  • RSC Advances (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • QUT ePrints (Queensland University of Technology) (submittedVersion, cc-by)
  • Griffith Research Online (submittedVersion, cc-by)
Funders
  • National Health and Medical Research Council (APP1037310, APP1182347)
  • National Heart Foundation of Australia (102761)
  • University of Queensland
Topics
  • Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
hydrogels, cell seeding, microfluidics, 3D cell culture, extracellular matrix, hydrogel scaffolds, hydrogel synthesis, hydrogel classification, cell microenvironment, mechanical environment

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.