CoChat

The association of FAD with the cytochrome b–245 of human neutrophils

Open access
Cross, Andrew R., Jones, Owen T. G., Garcia, Rudolfo, Segal, Anthony W. · 1982 · Biochemical Journal
Cited by 111

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A plasma membrane fraction prepared from human neutrophils had a fluorescence resembling that of a fluorescent flavoprotein, with emission maximum near 520nm and excitation maxima near 380 and 460nm. The fluorescence emission and excitation properties of Triton N-101-solubilized membrane fraction resembled those of FAD. FAD was present in the membranes at a concentration of 417pmol/mg of protein and cytochrome b–245 at a concentration of 407pmol/mg of protein. In a 110-fold purified preparation of cytochrome b–245 the ratio of FAD:cytochrome b was 1:1. Analytical gradient centrifugation of neutrophil homogenates shows a coincidence of two cytochrome b peaks and two peaks of fluorescence, corresponding with plasma membrane and specific granule fractions; most of the FAD was non-fluorescent and located in fractions lighter than the plasma membrane. Plasma membrane fractions prepared from neutrophils of patients suffering from the X-linked form of chronic granulomatous disease lacked cytochrome b and contained 194pmol of FAD/mg of protein; plasma membrane fractions prepared from neutrophils of patients with the autosomal recessive form of chronic granulomatous disease contained both cytochrome b–245 and FAD in the normal range of concentrations in a ratio of 1:1. Phagocytic vesicles were prepared from normal neutrophils and found to contain FAD and cytochrome b in a ratio 2.22:1, suggesting that activation of neutrophils many involve the incorporation of an additional flavin into the membrane. Under anaerobic conditions in the presence of EDTA to act as an electron donor to a flavin, the cytochrome b–245 of neutrophil membranes was partly (12%) photoreducible, an effect increased to 100% by the addition of FMN. The extent of reduction of cytochrome b in an anaerobic neutrophil homogenate containing NADH increased from 30% to 70% on illumination. We suggest that these results indicate a close association between FAD and cytochrome b–245 and support a scheme for electron transport thus: [Formula: see text]

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1042/bj2080759

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Cross, A. R., Jones, O. T. G., Garcia, R., & Segal, A. W.
Venue
Biochemical Journal
Published
1982-12-15
Volume
208
Issue
3
Pages
759-763
ISSN
0306-3283 (ISSN-L)
OpenAlex
W2260504541
Cited by
111
References
1
FWCI
5.44
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.