Finger Arterial versus Intrabrachial Pressure and Continuous Cardiac output during Head-up Tilt Testing in Healthy Subjects
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
1. The aims of this study were to determine the clinical feasibility of continuous, non-invasive Finapres recordings as a replacement for intrabrachial pressure during a 30 min head-up tilt, and the reliability of continuous cardiac output computation by pulse contour analysis from the finger arterial versus the brachial waveform. 2. In eight healthy subjects a 30 min 70° passive head-up tilt was performed. Finger arterial (FINAP) and intrabrachial (IAP) pressures were measured simultaneously. Beat-to-beat changes in stroke volume were computed using a pulse contour algorithm. 3. Accuracy (the group-averaged FINAP—IAP difference) and precision (the SD of the difference) of Finapres measurements were 4 and 9 mmHg for systolic blood pressure, −5 and 9 mmHg for mean blood pressure and −5 and 9 mmHg for diastolic blood pressure. 4. The time course of the FINAP—IAP differences during head-up tilt showed a linear trend (P < 0.001 for all pressure levels). Averaged for the group, the difference increased 7 mmHg for mean blood pressure. The difference in stroke volume computed from FINAP and IAP was 0.3 ± 5% (mean ± SD), and independent of the duration of the tilt (P > 0.05). This difference did not change at low blood pressure levels (0.5 ± 6%). 5. The qualitative performance of the Finapres allows it to be used in the clinical setting as a monitor of sudden changes in blood pressure induced by a 30 min head-up tilt. Relative changes in stroke volume, as obtained by pulse contour analysis of the finger arterial waveform, closely follow intrabrachial values during long-duration head-up tilt and associated arterial hypotension.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Cited by
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Self-citationAssessment of cardiac output from systemic arterial pressure in humans
Romano, S. M., & Pistolesi, M. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00027 · Cited by 616
Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
Self-citationManagement of Vasovagal Syncope: Controlling or Aborting Faints by Leg Crossing and Muscle Tensing
Krediet, C. T. P., van Dijk, N., Linzer, M., van Lieshout, J. J., & Wieling, W. (2002) · Circulation · doi:10.1161/01.cir.0000030939.12646.8f · Cited by 372
Syncope, cerebral perfusion, and oxygenation
Van Lieshout, J. J., Wieling, W., Karemaker, J. M., & Secher, N. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00260.2002 · Cited by 365
Metadata
- Authors
- Jellema, W. T., Imholz, B. P. M., Van Goudoever, J., Wesseling, K. H., & Van Lieshout, J. J.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1996-08-01
- Volume
- 91
- Issue
- 2
- Pages
- 193-200
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W2403237581
- Cited by
- 121
- References
- 2
- FWCI
- 5.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Finger Arterial versus Intrabrachial Pressure and Continuous Cardiac output during Head-up Tilt Testing in Healthy Subjects. https://app.cochat.ai/papers/10.1042/cs0910193
- The paper
- Jellema, W. T., Imholz, B. P. M., Van Goudoever, J., Wesseling, K. H., & Van Lieshout, J. J. (1996). Finger Arterial versus Intrabrachial Pressure and Continuous Cardiac output during Head-up Tilt Testing in Healthy Subjects. Clinical Science. https://doi.org/10.1042/cs0910193
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.