The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress
Abstract
The relationship between aortic flow and pressure is described by a three-element model of the arterial input impedance, including continuous correction for variations in the diameter and the compliance of the aorta (Modelflow). We computed the aortic flow from arterial pressure by this model, and evaluated whether, under orthostatic stress, flow may be derived from both an invasive and a non-invasive determination of arterial pressure. In 10 young adults, Modelflow stroke volume (MFSV) was computed from both intra-brachial arterial pressure (IAP) and non-invasive finger pressure (FINAP) measurements. For comparison, a computer-controlled series of four thermodilution estimates (thermodilution-determined stroke volume; TDSV) were averaged for the following positions: supine, standing, head-down tilt at 20 ° (HDT20) and head-up tilt at 30 ° and 70 ° (HUT30 and HUT70 respectively). Data from one subject were discarded due to malfunctioning thermodilution injections. A total of 155 recordings from 160 series were available for comparison. The supine TDSV of 113±13 ml (mean±S.D.) dropped by 40% to 68±14 ml during standing, by 24% to 86±12 ml during HUT30, and by 51% to 55±15 ml during HUT70. During HDT20, TDSV was 114±13 ml. MFSV for IAP underestimated TDSV during HDT20 (-6±6 ml; P < 0.05), but that for FINAP did not (-4±7 ml; not significant). For HUT70 and standing, MFSV for IAP overestimated TDSV by 11±10 ml (HUT70; P < 0.01) and 12±9 ml (standing; P < 0.01). However, the offset of MFSV for FINAP was not significant for either HUT70 (3±8 ml) or standing (3±9 ml). In conclusion, due to orthostasis, changes in the aortic transmural pressure may lead to an offset in MFSV from IAP. However, Modelflow correctly calculated aortic flow from non-invasively determined finger pressure during orthostasis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Consensus Committee of the American Autonomic Society and the American Academy of Neurology (1996) · Neurology · doi:10.1212/wnl.46.5.1470 · Cited by 1,243
Computation of aortic flow from pressure in humans using a nonlinear, three-element model
Wesseling, K. H., Jansen, J. R., Settels, J. J., & Schreuder, J. J. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2566 · Cited by 1,137
Self-citationRowell, L. B. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199312000-00021 · Cited by 1,092
Tilt table testing for assessing syncope
Benditt, D. G., Ferguson, D. W., Grubb, B. P., Kapoor, W. N., Kugler, J., Lerman, B. B., Maloney, J. D., Ravielle, A., Ross, B., Sutton, R., et al. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(96)00236-7 · Cited by 568
Langewouters, G. J., Wesseling, K. H., & Goedhard, W. J. A. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90034-4 · Cited by 544
Self-citationDirect Blood Pressure Measurement —Dynamic Response Requirements
Gardner, R. M. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00010 · Cited by 518
Methodology of head-up tilt testing in patients with unexplained syncope
Fitzpatrick, A. P., Theodorakis, G., Vardas, P., & Sutton, R. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90714-k · Cited by 432
Imholz, B. P. M., Settels, J. J., van der Meiracker, A. H., Wesseling, K. H., & Wieling, W. (1990) · Cardiovascular Research · doi:10.1093/cvr/24.3.214 · Cited by 344
Self-citationCOMPARISON OF THE FICK AND DYE INJECTION METHODS OF MEASURING THE CARDIAC OUTPUT IN MAN
Hamilton, W. F., Riley, R. L., Attyah, A. M., Cournand, A., Fowell, D. M., Himmelstein, A., Noble, R. P., Remington, J. W., Richards, D. W., Wheeler, N. C., et al. (1948) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1948.153.2.309 · Cited by 322
Cardiovascular Adjustments to Gravitational Stress
Blomqvist, C. G., & Stone, H. L. (1983) · Comprehensive Physiology · doi:10.1002/cphy.cp020328 · Cited by 291
Thermodilution cardiac output: A critical analysis and review of the literature
Levett, J. M., & Replogle, R. L. (1979) · Journal of Surgical Research · doi:10.1016/0022-4804(79)90159-8 · Cited by 241
Physiocal, calibrating finger vascular physiology for finapres
Wesseling, K. H., Wit, B. D., van der Hoeven, G. M. A., Goudoever, J. V., & Settels, J. J. (1995) · TU/e Research Portal · Cited by 229
Self-citationPostural changes in the circulation
Oh, G. (1965) · Medical Entomology and Zoology · Cited by 218
Jellema, W. T., Wesseling, K. H., Groeneveld, J. A. B., Stoutenbeek, C. P., Thijs, L. G., & van Lieshout, J. J. (1999) · Anesthesiology · doi:10.1097/00000542-199905000-00016 · Cited by 213
Self-citationCardiovascular dynamics during orthostasis and the influence of intravascular instrumentation
Stevens, P. M. (1966) · The American Journal of Cardiology · doi:10.1016/0002-9149(66)90354-7 · Cited by 169
Assessment of Windkessel as a model of aortic input impedance.
Burkhoff, D., Alexander, J., & Schipke, J. (1988) · American Journal of Physiology · doi:10.1152/ajpheart.1988.255.4.h742 · Cited by 146
Blood volume distribution during head‐up tilt induced central hypovolaemia in man
Matzen, S., Perko, G., Groth, S., Friedman, D. B., & Secher, N. H. (1991) · Clinical Physiology · doi:10.1111/j.1475-097x.1991.tb00813.x · Cited by 133
Self-citationJellema, W. T., Imholz, B. P. M., van Goudoever, J., Wesseling, K. H., & LIESHOUT, J. J. V. (1996) · Clinical Science · doi:10.1042/cs0910193 · Cited by 121
Self-citationPETERSEN, M. E. V., Williams, T. R., & Sutton, R. (1995) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060791 · Cited by 96
Maintenance of postural normotension in humans
Wieling, W., & LIESHOUT, J. J. V. (1997) · Cited by 89
Schreuder, J. J., van der Veen, F. H., van der Velde, E. T., Delahaye, F., Alfieri, O., Jegaden, O., Lorusso, R., Jansen, J. R. C., van Ommen, V., Finet, G., et al. (1995) · Circulation · doi:10.1161/01.cir.91.7.2010 · Cited by 87
Bos, W. J. W., Imholz, B. P. M., van Goudoever, J., et al. (1992) · American Journal of Hypertension · doi:10.1093/ajh/5.8.529 · Cited by 85
Non‐invasive blood pressure monitoring during head‐up tilt using the Penaz principle
Friedman, D. B., Jensen, F. B., Matzen, S., & Secher, N. H. (1990) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1990.tb03137.x · Cited by 81
Self-citationContinuous noninvasive cardiac output as estimated from the pulse contour curve
Gratz, I., Kraidin, J. L., Jacobi, A. G. M., deCastro, N. G., Spagna, P., & Larijani, G. E. (1992) · Journal of Clinical Monitoring and Computing · doi:10.1007/bf01618083 · Cited by 64
Single Injection Thermodilution
Jansen, J. R. C., Schreuder, J. J., Settels, J. J., Kornet, L., Penn, O. C. K. M., Mulder, P. G. H., Versprille, A., & Wesseling, K. H. (1996) · Anesthesiology · doi:10.1097/00000542-199609000-00006 · Cited by 33
Self-citationMuscle sympathetic nerve activity during postural change in healthy young and older adults
Ng, A. V., Johnson, D. G., Callister, R., & Seals, D. R. (1995) · Clinical Autonomic Research · doi:10.1007/bf01845500 · Cited by 30
ten Harkel, A. D. J., LIESHOUT, J. J. V., Karemaker, J. M., & Wieling, W. (1993) · Clinical Autonomic Research · doi:10.1007/bf01818996 · Cited by 30
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
Assessment of cardiac output from systemic arterial pressure in humans
Romano, S. M., & Pistolesi, M. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00027 · Cited by 616
Jansen, J. R. C., Schreuder, J. J., Mulier, J. P., Smith, N. T., Settels, J. J., & Wesseling, K. H. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.2.212 · Cited by 583
Self-citationRicci, F., De Caterina, R., & Fedorowski, A. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.06.1084 · Cited by 472
Metadata
- Authors
- HARMS, M. P. M., WESSELING, K. H., POTT, F., JENSTRUP, M., VAN GOUDOEVER, J., SECHER, N. H., & VAN LIESHOUT, J. J.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1999-07-21
- Volume
- 97
- Issue
- 3
- Pages
- 291-301
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W2072486627
- Cited by
- 345
- References
- 27
- FWCI
- 11.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.