The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Skin Melanin, Hemoglobin, and Light Scattering Properties can be Quantitatively Assessed In Vivo Using Diffuse Reflectance Spectroscopy
Open accessAbstract
Noninvasive and real-time analysis of skin properties is useful in a wide variety of applications. In particular, the quantitative assessment of skin in terms of hemoglobin and melanin content, as well as in terms of its light scattering properties, is a challenging problem in dermatology. We present here a technique for examining human skin, based on the in vivo measurement of diffuse reflectance spectra in the visible and near-infrared ranges of the electromagnetic spectrum. Spectra were measured by means of a fiber optic probe, and they were analyzed using an analytical model of light diffusion in the skin. The results of the analysis indicate that it is possible to obtain quantitative information about hemoglobin and melanin content, as well as basic information regarding the scattering properties of the skin.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“increased melanin reduces signal penetration into the blood-containing dermis, attenuating the AC component of the PPG signal.”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [10]
In the citing paper
“failing to correct for these errors exacerbates existing healthcare disparities [10,23,24,25,26]”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [10]
In the citing paper
“consistent with optical absorption by melanin in the green band and reduced pulsatile content reaching the photodiode [10,11,28].”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [10]
In the citing paper
“previous research demonstrated that inaccurate PPG HR measurements occur up to 15% more frequently in dark skin as compared to light skin”
From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [23]
In the citing paper
“likely because darker skin contains more melanin which absorbs more green light than lighter skin.”
From Investigating sources of inaccuracy in wearable optical heart rate sensors (2020) · cites this paper as [23]
In the citing paper
“This effect has been documented by other investigators68 and it may account for some of the errors experienced by dark skin individuals utilizing wearable based on PPG68–71.”
From Synthetic photoplethysmography (PPG) of the radial artery through parallelized Monte Carlo and its correlation to body mass index (BMI) (2021) · cites this paper as [70]
Citations
Cites
Born, M., Wolf, E., Bhatia, A. B., Clemmow, P. C., Gabor, D., Stokes, A. R., Taylor, A. M., Wayman, P. A., & Wilcock, W. L. (1999) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,627
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Farrell, T. J., Patterson, M. S., & Wilson, B. C. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,380
In Vivo Confocal Scanning Laser Microscopy of Human Skin: Melanin Provides Strong Contrast
Rajadhyaksha, M. M., Grossman, M. C., Esterowitz, D., Webb, R. H., & Anderson, R. R. (1995) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12606215 · Cited by 1,090
Principles of color technology
Billmeyer, F. W., & Saltzman, M. (1981) · Cited by 814
van Gemert, M. J. C., Jacques, S. L., Sterenborg, H. J. C. M., & Star, W. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.42108 · Cited by 807
Mourant, J. R., Freyer, J. P., Hielscher, A. H., Eick, A. A., Shen, D., & Johnson, T. M. (1998) · Applied Optics · doi:10.1364/ao.37.003586 · Cited by 682
Diffuse reflectance spectroscopy of human adenomatous colon polyps in vivo
Zonios, G. I., Perelman, L. T., Backman, V., Manoharan, R., Fitzmaurice, M., Dam, J. V., & Feld, M. S. (1999) · Applied Optics · doi:10.1364/ao.38.006628 · Cited by 532
Self-citationPerelman, L. T., Backman, V., Wallace, M. B., Zonios, G. I., Manoharan, R., Nusrat, A., Shields, S. J., Seiler, M., Lima, C., Hamano, T., et al. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.627 · Cited by 492
Self-citationKollias, N., Sayre, R. M., Zeise, L., & Chedekel, M. R. (1991) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/1011-1344(91)80147-a · Cited by 482
Self-citation
Research works printed but not linked: 1
- Press, 1992, 681
Cited by
Sorted by citations
Shedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,902
Molecular imaging in drug discovery and development
Rudin, M., & Weissleder, R. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1007 · Cited by 811
Rare-earth-doped biological composites as in vivo shortwave infrared reporters
Naczynski, D. J., Tan, M. C., Zevon, M., Wall, B., Kohl, J., Kulesa, A. B., Chen, S., Roth, C. M., Riman, R. E., & Moghe, P. V. (2013) · Nature Communications · doi:10.1038/ncomms3199 · Cited by 766
Investigating sources of inaccuracy in wearable optical heart rate sensors
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0226-6 · Cited by 673
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Metadata
- Authors
- Zonios, G., Bykowski, J., & Kollias, N.
- Affiliations
- Harvard University (US)
- Corresponding author
- Kollias, Nikiforos
- Venue
- Journal of Investigative Dermatology
- Publisher
- Elsevier BV
- Published
- 2001-12
- Volume
- 117
- Issue
- 6
- Pages
- 1452-1457
- ISSN
- 0022-202X (ISSN-L)
- OpenAlex
- W2089724274
- Cited by
- 477
- References
- 30
- Citations by year
- 2026: 11 · 2025: 27 · 2024: 35 · 2023: 20 · 2022: 16 · 2021: 32 · 2020: 25 · 2019: 29 · 2018: 25 · 2017: 17 · 2016: 28 · 2015: 30 · 2014: 18 · 2013: 29 · 2012: 17
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Investigative Dermatology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Health Sciences › Medicine › Oncology › Cutaneous Melanoma Detection and Management
- Keywords
- skin melanin, light scattering properties, diffuse reflectance spectroscopy, in vivo skin measurement, optical fiber probe, visible and near-infrared spectra
- MeSH terms
- Fiber Optic Technology, Hemoglobins, Humans, Melanins, Models, Biological, Scattering, Radiation, Skin, Skin Pigmentation, Spectroscopy, Near-Infrared, Optical Fibers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review