Near‐infrared spectroscopy for monitoring muscle oxygenation
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Near‐infrared spectroscopy (NIRS) is a non‐invasive method for monitoring oxygen availability and utilization by the tissues. In intact skeletal muscle, NIRS allows semi‐quantitative measurements of haemoglobin plus myoglobin oxygenation (tissue O 2 stores) and the haemoglobin volume. Specialized algorithms allow assessment of the oxidation–reduction (redox) state of the copper moiety (CuA) of mitochondrial cytochrome c oxidase and, with the use of specific tracers, accurate assessment of regional blood flow. NIRS has demonstrated utility for monitoring changes in muscle oxygenation and blood flow during submaximal and maximal exercise and under pathophysiological conditions including cardiovascular disease and sepsis. During work, the extent to which skeletal muscles deoxygenate varies according to the type of muscle, type of exercise and blood flow response. In some instances, a strong concordance is demonstrated between the fall in O 2 stores with incremental work and a decrease in CuA oxidation state. Under some pathological conditions, however, the changes in O 2 stores and redox state may diverge substantially.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Wray, S., Cope, M., Delpy, D. T., Wyatt, J. S., & Reynolds, E. O. R. (1988) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(88)90069-2 · Cited by 912
van der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427
Hiraoka, M., Firbank, M., Essenpreis, M., Cope, M., Arridge, S. R., Zee, P. V. D., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/12/011 · Cited by 374
COTSIDE MEASUREMENT OF CEREBRAL BLOOD FLOW IN ILL NEWBORN INFANTS BY NEAR INFRARED SPECTROSCOPY
Edwards, A. D., Richardson, C., Cope, M., Wyatt, J. S., Delpy, D. T., & Reynolds, E. O. R. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92418-x · Cited by 370
Near infrared monitoring of human skeletal muscle oxygenation during forearm ischemia
Hampson, N. B., & Piantadosi, C. A. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.6.2449 · Cited by 300
Self-citationNoninvasive measurement of forearm blood flow and oxygen consumption by near-infrared spectroscopy
De Blasi, R. A., Ferrari, M., Natali, A., Conti, G., Mega, A., & Gasparetto, A. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.3.1388 · Cited by 292
Noninvasive measures of oxidative metabolism on working human muscles by near-infrared spectroscopy
Hamaoka, T., Iwane, H., Shimomitsu, T., Katsumura, T., Murase, N., Nishio, S., Osada, T., Kurosawa, Y., & Chance, B. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.3.1410 · Cited by 280
Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy
De Blasi, R. A., Cope, M., Elwell, C., Safoue, F., & Ferrari, M. (1993) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00377698 · Cited by 238
Fractionation of the Cardiac Output of Rats with Isotopic Potassium
SAPIRSTEIN, L. A. (1956) · Circulation Research · doi:10.1161/01.res.4.6.689 · Cited by 208
Cited by
Muscle fatigue: what, why and how it influences muscle function
Enoka, R. M., & Duchateau, J. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.139477 · Cited by 1,672
Why is the partial oxygen pressure of human tissues a crucial parameter? Small molecules and hypoxia
Carreau, A., Hafny‐Rahbi, B. E., Matejuk, A., Grillon, C., & Kieda, C. (2011) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2011.01258.x · Cited by 1,246
“NIRS is a non-invasive, optical technique applying the principles of light transmission and absorption to investigate dynamic changes in tissue oxygenation by measuring haemoglobin saturation [9].”
MethodPrinciples, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Wittenberg, J. B., & Wittenberg, B. A. (2003) · Journal of Experimental Biology · doi:10.1242/jeb.00243 · Cited by 550
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Monitoring the microcirculation in the critically ill patient: current methods and future approaches
De Backer, D., Ospina-Tascon, G., Salgado, D., Favory, R., Creteur, J., & Vincent, J.-L. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-2005-3 · Cited by 426
DeLorey, D. S., Kowalchuk, J. M., & Paterson, D. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00956.2002 · Cited by 369
Cerebral blood flow and metabolism during exercise: implications for fatigue
Secher, N. H., Seifert, T., & Van Lieshout, J. J. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00853.2007 · Cited by 344
“NIRS. NIRS is used to evaluate muscle O2 extraction during muscular activity (3, 4, 7 , 31, 42), and maximal rowing affects light absorption related to an increase in muscle Hb (9) and a decrease in oxygenated Hb (41).”
MethodHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Flexible graphene photodetectors for wearable fitness monitoring
Polat, E. O., Mercier, G., Nikitskiy, I., Puma, E., Galan, T., Gupta, S., Montagut, M., Piqueras, J. J., Bouwens, M., Durduran, T., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw7846 · Cited by 298
Significant Molecular and Systemic Adaptations after Repeated Sprint Training in Hypoxia
Faiss, R., Léger, B., Vesin, J.-M., Fournier, P.-E., Eggel, Y., Dériaz, O., & Millet, G. P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056522 · Cited by 294
Can Near-Infrared Spectroscopy Identify the Severity of Shock in Trauma Patients?
Crookes, B. A., Cohn, S. M., Bloch, S., Amortegui, J., Manning, R., Li, P., Proctor, M. S., Hallal, A., Blackbourne, L. H., Benjamin, R., et al. (2005) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000158269.68409.1c · Cited by 211
Passive versus Active Recovery during High-Intensity Intermittent Exercises
DUPONT, G., MOALLA, W., GUINHOUYA, C., AHMAIDI, S., & BERTHOIN, S. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000113477.11431.59 · Cited by 159
“Several studies (12,28) have reported that the adipose tissue thickness has an effect on light propagation in muscles.”
BackgroundDoerschug, K. C., Delsing, A. S., Schmidt, G. A., & Ashare, A. (2010) · Critical Care · doi:10.1186/cc8887 · Cited by 119
Celie, B., Boone, J., Van Coster, R., & Bourgois, J. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2183-x · Cited by 59
“Three molecules account for most of the NIRS light absorption: oxygenated and deoxygenated hemoglobin (Hb), myoglobin (Mb) and cytochrome oxidase c (Boushel and Piantadosi 2001).”
BackgroundEvaluation of cuff-induced ischemia in the lower extremity by magnetic resonance oximetry
Langham, M. C., Floyd, T. F., Mohler, E. R., Magland, J. F., & Wehrli, F. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.08.068 · Cited by 46
“he separation of the source-detector probes determines the epth of the layer being probed, and the true path of the nfrared light is not known (5).”
Quaresima, V., Ferrari, M., Franceschini, M. A., Hoimes, M. L., & Fantini, S. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1646417 · Cited by 45
Fellahi, J.-L., Butin, G., Fischer, M.-O., Zamparini, G., Gérard, J.-L., & Hanouz, J.-L. (2013) · Journal of Critical Care · doi:10.1016/j.jcrc.2013.05.004 · Cited by 42
Koga, S., Poole, D. C., Kondo, N., Oue, A., Ohmae, E., & Barstow, T. J. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-014-3019-2 · Cited by 39
KOMIYAMA, T., QUARESIMA, V., SHIGEMATSU, H., & FERRARI, M. (2001) · Clinical Science · doi:10.1042/cs1010715 · Cited by 31
Lee, J.-H., Park, Y.-H., Kim, H.-S., & Kim, J.-T. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-014-9595-1 · Cited by 20
Muscle deoxygenation of upper-limb muscles during progressive arm-cranking exercise
Lusina, S.-J. C., Warburton, D. E. R., Hatfield, N. G., & Sheel, A. W. (2008) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h07-156 · Cited by 18
Metadata
- Authors
- Boushel, R., & Piantadosi, C. A.
- Venue
- Acta Physiologica Scandinavica
- Publisher
- Wiley
- Published
- 2000-04
- Volume
- 168
- Issue
- 4
- Pages
- 615-622
- ISSN
- 0001-6772 (ISSN-L)
- 1365-201X
- OpenAlex
- W2094344644
- Cited by
- 299
- References
- 25
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.