Compliance properties of conduits used in vascular reconstruction
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Background: Compliance mismatch between native artery and prosthetic graft used for infrainguinal bypass is implicated in the aetiology of graft failure. The aim was to quantify the elastic properties of a new compliant poly(carbonate)polyurethane (CPU) vascular graft, and to compare the compliance properties of grafts made from CPU, expanded polytetrafluoroethylene (ePTFE), Dacron and human saphenous vein with that of human muscular artery. Methods: A pulsatile flow phantom was used to perfuse vessel and prosthetic graft segments at physiological pulse pressure and flow. Intraluminal pressure was measured using a Millar Mikro-tip catheter transducer and vessel wall motion was determined with duplex ultrasonography using an echo-locked wall-tracking system. Diametrical compliance and a stiffness index were then calculated for each type of conduit over mean pressures ranging from 30 to 100 mmHg by 10-mmHg increments. Results: The compliance values of CPU and artery (mean over the pressure range) were similar (mean(s.d.) 8·1(0·4) and 8·0(5·9) per cent per mmHg × 10−2 respectively), although the elastic behaviour of artery was anisotropic unlike CPU, which was isotropic. Dacron and ePTFE grafts had lower compliance values (1·8(1·2) and 1·2(0·3) per cent per mmHg × 10−2 respectively, averaged over the pressure range). In both these cases, compliance and stiffness differed significantly from that of artery over a mean pressure range of 30–90 mmHg. Human saphenous vein exhibited anisotropic behaviour and, although compliant at low pressure (30 mmHg), was markedly incompliant at higher pressures. Conclusion: Compliant polyurethane grafts offer a greater degree of compliance match than either ePTFE or Dacron.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Principles in Experimental Design
Green, P. E., Winer, B. J., Brown, D. R., & Michels, K. M. (1992) · Journal of Marketing Research · doi:10.2307/3172747 · Cited by 4,333
Veith, F. J., Gupta, S. K., Ascer, E., White-Flores, S., Samson, R. H., Scher, L. A., Towne, J. B., Bernhard, V. M., Bonier, P., Flinn, W. R., et al. (1986) · Journal of Vascular Surgery · doi:10.1016/0741-5214(86)90073-x · Cited by 1,112
The Mechanics of the Circulation
Caro, C. G., Pedley, T. J., Schroter, R. C., Seed, W. A., & Parker, K. H. (2011) · Cambridge University Press eBooks · doi:10.1017/cbo9781139013406 · Cited by 912
Relation of Structure to Function of the Tissues of the Wall of Blood Vessels
Burton, A. C. (1954) · Physiological Reviews · doi:10.1152/physrev.1954.34.4.619 · Cited by 798
Mechanical Properties of Arteries in Vivo
PETERSON, L. H., JENSEN, R. E., & PARNELL, J. (1960) · Circulation Research · doi:10.1161/01.res.8.3.622 · Cited by 679
KAWASAKI, T., SASAYAMA, S., YAGI, S.-I., ASAKAWA, T., & HIRAI, T. (1987) · Cardiovascular Research · doi:10.1093/cvr/21.9.678 · Cited by 655
The Mechanics of the Circulation.
(1979) · Annals of Internal Medicine · doi:10.7326/0003-4819-90-5-867_1 · Cited by 626
Effect of compliance mismatch on vascular graft patency
Abbott, W. M., Megerman, J., Hasson, J. E., L'Italien, G., & Warnock, D. F. (1987) · Journal of Vascular Surgery · doi:10.1016/0741-5214(87)90148-0 · Cited by 484
Assessment of the distensibility of superficial arteries
Hoeks, A. P. G., Brands, P. J., Smeets, F. A. M., & Reneman, R. S. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90139-4 · Cited by 479
Polyurethane Elastomer Biostability
Stokes, K., McVenes, R., & Anderson, J. M. (1995) · Journal of Biomaterials Applications · doi:10.1177/088532829500900402 · Cited by 366
Cited by
Non-toxic antifouling strategies
Magin, C. M., Cooper, S. P., & Brennan, A. B. (2010) · Materials Today · doi:10.1016/s1369-7021(10)70058-4 · Cited by 551
Long term performance of polycaprolactone vascular grafts in a rat abdominal aorta replacement model
de Valence, S., Tille, J.-C., Mugnai, D., Mrowczynski, W., Gurny, R., Möller, M., & Walpoth, B. H. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.09.024 · Cited by 423
The Mechanical Properties of Infrainguinal Vascular Bypass Grafts: Their Role in Influencing Patency
Sarkar, S., Salacinski, H. J., Hamilton, G., & Seifalian, A. M. (2006) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2006.01.006 · Cited by 301
Self-citationIntroductory biomechanics: from cells to organisms
(2007) · Choice Reviews Online · doi:10.5860/choice.45-1476 · Cited by 241
Seifalian, A. M., Tiwari, A., Hamilton, G., & Salacinski, H. J. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06841.x · Cited by 225
Self-citationElectrospun polydioxanone–elastin blends: potential for bioresorbable vascular grafts
Sell, S. A., McClure, M. J., Barnes, C. P., Knapp, D. C., Walpoth, B. H., Simpson, D. G., & Bowlin, G. L. (2006) · Biomedical Materials · doi:10.1088/1748-6041/1/2/004 · Cited by 216
Medical Textiles as Vascular Implants and Their Success to Mimic Natural Arteries
Singh, C., Wong, C., & Wang, X. (2015) · Journal of Functional Biomaterials · doi:10.3390/jfb6030500 · Cited by 196
“The consequences of poor compliance can be fatal as it can change the transmission characteristics of pulse waves [4,32,33].”
BackgroundYin, A., Luo, R., Li, J., Mo, X., Wang, Y., & Zhang, X. (2017) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2017.01.045 · Cited by 45
Metadata
- Authors
- Tai, N. R., Salacinski, H. J., Edwards, A., Hamilton, G., & Seifalian, A. M.
- Venue
- Journal of British Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-11-01
- Volume
- 87
- Issue
- 11
- Pages
- 1516-1524
- ISSN
- 0007-1323 (ISSN-L)
- 1365-2168
- OpenAlex
- W2078355519
- Cited by
- 267
- References
- 26
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.