CoChat

Validation of skinfold thickness and hand‐held impedance measurements for estimation of body fat percentage among Singaporean Chinese, Malay and Indian subjects

Deurenberg, Paul, Deurenberg‐Yap, Mabel · 2002 · Asia Pacific Journal of Clinical Nutrition
Cited by 79

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Body fat percentage (BF%) was measured in 298 Singaporean Chinese, Malay and Indian men and women using a chemical four‐compartment model consisting of fat, water, protein and mineral (BF%4C). In addition, weight, height, skinfold thickness and segmental impedance (from hand to hand) was measured. Body fat percentage was predicted using prediction equations from the literature (for skinfolds BF%SKFD) and using the manufacturer’s software for the hand‐held impedance analyser (BF%IMP). The subjects ranged in age from 18–70 years and in body mass index from 16.0 to 40.2 kg/m 2. Body fat ranged from 6.5 to 53.3%. The biases for skinfold prediction (BF%4C–BF%SKFD, mean ± SD) were –0.4 ± 3.9, 2.3 ± 4.1 and 3.1 ± 4.2 in Chinese, Malay and Indian women, respectively, the Chinese being different from the Malays and Indians. The differences were significant from zero (P< 0.05) in the Malays and Indians. For the men, the biases were 0.5 ± 3.8, 0.0 ± 4.8 and 0.9 ± 4.0 in Chinese, Malays and Indians, respectively. These biases were not significantly different from zero and not different among the ethnic groups. The biases for hand‐held impedance BF% were –0.7 ± 4.5, 1.5 ± 4.4 and 0.4 ± 3.8 in Chinese, Malay and Indian women. These biases were not significantly different from zero but the bias in the Chinese was significantly different from the biases in the Malays and Indians. In the Chinese, Malay and Indian men, the biases of BF%IMP were 0.7 ± 4.6, 1.9 ± 4.8 and 2.0 ± 4.4, respectively. These biases in Malay and Indian men were significantly different from zero and significantly different from the bias in Chinese men. The biases were correlated with level of body fat and age, and also with relative arm span (arm span/height) for impedance. After correction, the differences in bias among the ethnic groups disappeared. The study shows that the biases in predicted BF% differ between ethnic groups, differences that can be explained by differences in body composition and differences in body build. This information is important and should be taken into account when comparing body composition across ethnic groups using predictive methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1440-6047.2002.00258.x

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 79

Metadata

Authors
Deurenberg, P., & Deurenberg‐Yap, M.
Venue
Asia Pacific Journal of Clinical Nutrition
Publisher
Wiley
Published
2002-02-26
Volume
11
Issue
1
Pages
1-7
ISSN
  • 0964-7058 (ISSN-L)
  • 1440-6047
OpenAlex
W2170525762
Cited by
79
References
13
FWCI
2.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.