A quantitative study of gamma‐band activity in human intracranial recordings triggered by visual stimuli
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
This paper studies gamma‐band responses from two implanted epileptic patients during a simple visual discrimination task. Our main aim was to ascertain, in a reliable manner, whether evoked (stimulus‐locked) and induced (triggered by, but not locked to, stimuli) responses are present in intracranial recordings. For this purpose, we introduce new methods adapted to detect the presence of gamma responses at this level of recording, intermediary between EEG‐scalp and unicellular responses. The analysis relies on a trial‐by‐trial time–frequency analysis and on the use of surrogate data for statistical testing. We report that visual stimulation reliably elicits evoked and induced responses in human intracranial recordings. Induced intracranial gamma activity is significantly present in short oscillatory bursts (a few cycles) following visual stimulation. These responses are highly variable from trial to trial, beginning after 200 ms and lasting up to 500 ms. In contrast, intracranial‐evoked gamma responses concentrate around 100 ms latencies corresponding to evoked responses observed on the scalp. We discuss our results in relation to scalp gamma response in a similar protocol [Tallon‐Baudry et al. (1996) J. Neurosci., 16, 4240–4249] and draw some conclusions for bridging the gap between gamma oscillations observed on the scalp surface and their possible cortical sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gray, C. M., König, P., Engel, A. K., & Singer, W. (1989) · Nature · doi:10.1038/338334a0 · Cited by 4,183
Perception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915
Self-citationGamma (40-100 Hz) oscillation in the hippocampus of the behaving rat
Bragin, A., Jando, G., Nadasdy, Z., Hetke, J., Wise, K., & Buzsaki, G. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-01-00047.1995 · Cited by 1,527
Visuomotor integration is associated with zero time-lag synchronization among cortical areas
Roelfsema, P. R., Engel, A. K., König, P., & Singer, W. (1997) · Nature · doi:10.1038/385157a0 · Cited by 1,136
Coherent 40-Hz oscillation characterizes dream state in humans.
Llinás, R., & Ribary, U. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.5.2078 · Cited by 962
Destexhe, A., Contreras, D., & Steriade, M. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-11-04595.1999 · Cited by 573
Episodic multiregional cortical coherence at multiple frequencies during visual task performance
Bressler, S. L., Coppola, R., & Nakamura, R. (1993) · Nature · doi:10.1038/366153a0 · Cited by 533
Desmedt, J. E., & Tomberg, C. (1994) · Neuroscience Letters · doi:10.1016/0304-3940(94)90432-4 · Cited by 240
Cited by
The brainweb: phase synchronization and large-scale integration
Varela, F., Lachaux, J.-P., Rodriguez, E., & Martinerie, J. (2001) · Nature Reviews Neuroscience · doi:10.1038/35067550 · Cited by 4,761
Self-citationMeasuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798
Self-citationComparison of Hilbert transform and wavelet methods for the analysis of neuronal synchrony
Le Van Quyen, M., Foucher, J., Lachaux, J.-P., Rodriguez, E., Lutz, A., Martinerie, J., & Varela, F. J. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00372-7 · Cited by 887
Self-citationScaling Brain Size, Keeping Timing: Evolutionary Preservation of Brain Rhythms
Buzsáki, G., Logothetis, N., & Singer, W. (2013) · Neuron · doi:10.1016/j.neuron.2013.10.002 · Cited by 886
Transient induced gamma-band response in EEG as a manifestation of miniature saccades
Yuval-Greenberg, S., Tomer, O., Keren, A. S., Nelken, I., & Deouell, L. Y. (2008) · Neuron · doi:10.1016/j.neuron.2008.03.027 · Cited by 776
“…duration (Lachaux et al., 2005; Tallon-Baudry et al., 2005; Trautner et al., 2006), higher frequencies (Tallon-Baudry et al., 2005), and highly constrained distribution (Lachaux et al., 2000; Tallon-Baudry et al., 2005) or it was insensitive to experimental manipulations (Lachaux et al., 2000).”
BackgroundInfluential
Metadata
- Authors
- Lachaux, J., Rodriguez, E., Martinerie, J., Adam, C., Hasboun, D., & Varela, F. J.
- Venue
- European Journal of Neuroscience
- Publisher
- Wiley
- Published
- 2000-07
- Volume
- 12
- Issue
- 7
- Pages
- 2608-2622
- ISSN
- 0953-816X (ISSN-L)
- 1460-9568
- OpenAlex
- W2073040164
- Cited by
- 139
- References
- 8
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A quantitative study of gamma‐band activity in human intracranial recordings triggered by visual stimuli. https://app.cochat.ai/papers/10.1046/j.1460-9568.2000.00163.x
- The paper
- Lachaux, J., Rodriguez, E., Martinerie, J., Adam, C., Hasboun, D., & Varela, F. J. (2000). A quantitative study of gamma‐band activity in human intracranial recordings triggered by visual stimuli. European Journal of Neuroscience. https://doi.org/10.1046/j.1460-9568.2000.00163.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.