Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 308

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Clinical Study of the Laser Sheath for Lead Extraction: The Total Experience in the United States

BYRD, CHARLES L., WILKOFF, BRUCE L., LOVE, CHARLES J., SELLERS, T. DUNCAN, REISER, CHRISTOPHER·2002·Pacing and Clinical Electrophysiology

Abstract

BYRD, C.L., et al.: Clinical Study of the Laser Sheath for Lead Extraction: The Total Experience in the United States. The laser sheath uses optical fibers, delivering pulsed ultraviolet excimer laser light, to vaporize fibrotic tissue binding intravenous cardiac leads to the vein or heart wall during lead extraction from the implant vein. The total investigational experience with laser sheaths is reported. During the period from October 1995 to December 1999, 2,561 pacing and defibrillator leads were treated in 1,684 patients at 89 sites in the United States with three sizes of laser sheath. Endpoints were complete removal of the lead, partial removal (leaving the tip behind), or failure (abandoning the lead, onset of complications, change to transfemoral or transatrial approach). Minimal follow‐up at 30 days was recorded. Of the leads, 90% were completely removed, 3% were partially removed, and the balance were failures. Major perioperative complications (tamponade, hemothorax, pulmonary embolism, lead migration, and death) were observed in 1.9% of patients with in hospital death in 13 (0.8%). Minor complications were seen in an additional 1.4% of patients. Multivariate analysis showed that implant duration was the only preoperative independent predictor of failure; female sex was the only multivariate predictor of complications. Success and complications were not dependent on laser sheath size. At follow‐up, various extraction related complications were observed in 2% of patients. The learning curve showed a trend toward fewer complications with experience. Lead extraction with the laser sheath can be safely practiced with high success rates. Success is independent of laser sheath size. Major complications can be expected in < 2% of patients, and occur more often during an investigator's early experience.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1460-9592.2002.t01-1-00804.x

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 308

Metadata

Authors
BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., & REISER, C.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2002-05
Volume
25
Issue
5
Pages
804-808
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2046028307
Cited by
308
References
8
FWCI
6.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Study of the Laser Sheath for Lead Extraction: The Total Experience in the United States. https://app.cochat.ai/papers/10.1046/j.1460-9592.2002.t01-1-00804.x
The paper
BYRD, C. L., WILKOFF, B. L., LOVE, C. J., SELLERS, T. D., & REISER, C. (2002). Clinical Study of the Laser Sheath for Lead Extraction: The Total Experience in the United States. Pacing and Clinical Electrophysiology. https://doi.org/10.1046/j.1460-9592.2002.t01-1-00804.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.