Long‐Term Complication Rates in Ventricular, Single Lead VDD, and Dual Chamber Pacing
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A higher incidence of pacemaker related complications has been reported in DDD systems as compared to VVI devices. The implantation of single lead VDD pacemakers might reduce the complication rate of physiological pacing in patients with AV block. In a retrospective study, the data records of 1,214 consecutive patients with pacemaker implantation for AV block between 1990 and 2001 (VVI 36.5%, DDD 32.9%, VDD 30.6%) were analyzed. Complications requiring surgical interventions were compared during a follow‐up period of 64 ± 31 months. Operation and fluoroscopic times were longer in DDD pacemaker implantation compared to VDD and VVI devices: 58 ± 23 versus 39 ± 10 and 37 ± 13 minutes (P < 0.001), 9.2 ± 5.2 versus 4.1 ± 2.4 and 3.5 ± 2.3 minutes , respectively. Differences remained significant after correction for covariates. In a multivariate Cox regression model, the corrected complication hazard of a DDD pacemaker implantation was increased by 3.9 (1.4–11.3) compared to VVI and increased by 2.3 (1.1–4.5) compared to VDD pacing. Higher complication rates in DDD pacing were mainly due to a higher incidence of early reoperation for atrial lead dysfunction, whereas the long‐term complication rate was not different from VDD or VVI pacing. Early and long‐term complication rates did not differ between VDD and VVI pacemaker systems. In conclusion, operation time and complication rates of physiological pacing are reduced by VDD pacemaker implantation achieving values comparable to VVI pacing. Thus, single lead VDD pacing can be recommended for patients with AV block. (PACE 2003; 26:1961–1969)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841
Connolly, S. J., Kerr, C. R., Gent, M., Roberts, R. S., Yusuf, S., Gillis, A. M., Sami, M. H., Talajic, M., Tang, A. S. L., Klein, G. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421902 · Cited by 775
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Udo, E. O., Zuithoff, N. P. A., van Hemel, N. M., de Cock, C. C., Hendriks, T., Doevendans, P. A., & Moons, K. G. M. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.014 · Cited by 597
“tricular block showed age at implantation to be an independent risk factor for complications.(6) The MOST study with 010 DDDR implants for sinus node disease, however, ould not show any relationship between age and compliations.”
BackgroundMethodCardiac Device Implantation in the United States from 1997 through 2004: A Population-based Analysis
Zhan, C., Baine, W. B., Sedrakyan, A., & Steiner, C. (2008) · Journal of General Internal Medicine · doi:10.1007/s11606-007-0392-0 · Cited by 266
Permanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review
Tjong, F. V. Y., & Reddy, V. Y. (2017) · Circulation · doi:10.1161/circulationaha.116.025037 · Cited by 228
Metadata
- Authors
- WIEGAND, U. K. H., BODE, F., BONNEMEIER, H., EBERHARD, F., SCHLEI, M., & PETERS, W.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 2003-10
- Volume
- 26
- Issue
- 10
- Pages
- 1961-1969
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2043900744
- Cited by
- 106
- References
- 2
- FWCI
- 2.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.