Self‐monitoring in Type 2 diabetes mellitus: a meta‐analysis
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
SUMMARY Aims Self‐monitoring of blood or urine glucose is widely used by subjects with Type 2 diabetes mellitus. This study evaluated the effectiveness of the technique at improving blood glucose control through a systematic review and meta‐analysis. Methods Randomized controlled trials were identified that compared the effects of blood or urine glucose monitoring with no self‐monitoring, or blood glucose self‐monitoring with urine glucose self‐monitoring, on glycated haemoglobin as primary outcome in Type 2 diabetes. Results Eight reports were identified. These were rated for quality and data were abstracted. The mean (sd) quality score was 15.0 (1.69) on a scale ranging from 0 to 28. No study had sufficient power to detect differences in glycated haemoglobin (GHb) of less than 0.5%. One study was excluded because it was a cluster randomized trial of a complex intervention and one because fructosamine was used as the outcome measure. A meta‐analysis was performed using data from four studies that compared blood or urine monitoring with no regular monitoring. The estimated reduction in GHb from monitoring was −0.25% (95% confidence interval −0.61 to 0.10%). Three studies that compared blood glucose monitoring with urine glucose monitoring were also combined. The estimated reduction in GHb from monitoring blood glucose rather than urine glucose was −0.03% (−0.52 to 0.47%). Conclusions The results do not provide evidence for clinical effectiveness of an item of care with appreciable costs. Further work is needed to evaluate self‐monitoring so that resources for diabetes care can be used more efficiently.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Stratton, I. M. (2000) · BMJ · doi:10.1136/bmj.321.7258.405 · Cited by 9,059
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252
Moher, D., Cook, D. J., Eastwood, S., Olkin, I., Rennie, D., & Stroup, D. F. (1999) · The Lancet · doi:10.1016/s0140-6736(99)04149-5 · Cited by 4,826
The Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Frison, L., & Pocock, S. J. (1992) · Statistics in Medicine · doi:10.1002/sim.4780111304 · Cited by 593
Senn, S., Frison, L., & Pocock, S. (1994) · Statistics in Medicine · doi:10.1002/sim.4780130210 · Cited by 529
Evans, J. M. M., Newton, R. W., Ruta, D. A., MacDonald, T. M., Stevenson, R. J., & Morris, A. D. (1999) · BMJ · doi:10.1136/bmj.319.7202.83 · Cited by 283
Implementation of Treatment Protocols in the Diabetes Control and Complications Trial
Diabetes Control and Complications Trial Research Group (1995) · Diabetes Care · doi:10.2337/diacare.18.3.361 · Cited by 283
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
“Similar conclusions were drawn in an early (2000) meta-analysis (97) of a sample of patients with type 2 diabetes in the NHANES (98) and the Freemantle Diabetes Study (99).”
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,130
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
“Similar conclusions were drawn in an early (2000) meta-analysis (97) of a sample of patients with type 2 diabetes in the NHANES (98) and the Freemantle Diabetes Study (99).”
Karter, A. J., Ackerson, L. M., Darbinian, J. A., D’Agostino, R. B., Ferrara, A., Liu, J., & Selby, J. V. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(01)00742-2 · Cited by 595
Does monitoring goal progress promote goal attainment? A meta-analysis of the experimental evidence.
Harkin, B., Webb, T. L., Chang, B. P. I., Prestwich, A., Conner, M., Kellar, I., Benn, Y., & Sheeran, P. (2016) · Psychological Bulletin · doi:10.1037/bul0000025 · Cited by 564
Farmer, A., Wade, A., Goyder, E., Yudkin, P., French, D., Craven, A., Holman, R., Kinmonth, A.-L., & Neil, A. (2007) · BMJ · doi:10.1136/bmj.39247.447431.be · Cited by 407
“so does the challenge of monitoring and managing the condition. Self monitoring of blood glucose for people with non-insulin treated diabetes may lead to improved glycaemic control and is commonly recommended. Existing evidence of effectiveness is, however, inconclusive.”
BackgroundSelf-Monitoring of Blood Glucose in Patients With Type 2 Diabetes Who Are Not Using Insulin
Welschen, L. M. C., Bloemendal, E., Nijpels, G., Dekker, J. M., Heine, R. J., Stalman, W. A. B., & Bouter, L. M. (2005) · Diabetes Care · doi:10.2337/diacare.28.6.1510 · Cited by 374
Assessing Glycemia in Diabetes Using Self-monitoring Blood Glucose and Hemoglobin A 1c
Saudek, C. D., Derr, R. L., & Kalyani, R. R. (2006) · JAMA · doi:10.1001/jama.295.14.1688 · Cited by 373
Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin
Malanda, U. L., Welschen, L. M., Riphagen, I. I., Dekker, J. M., Nijpels, G., & Bot, S. D. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005060.pub3 · Cited by 358
Nyenwe, E. A., Jerkins, T. W., Umpierrez, G. E., & Kitabchi, A. E. (2011) · Metabolism · doi:10.1016/j.metabol.2010.09.010 · Cited by 343
Lawton, J., Ahmad, N., Hanna, L., Douglas, M., & Hallowell, N. (2006) · Health Education Research · doi:10.1093/her/cyh042 · Cited by 333
The Evidence for Medical Nutrition Therapy for Type 1 and Type 2 Diabetes in Adults
Franz, M. J., Powers, M. A., Leontos, C., Holzmeister, L. A., Kulkarni, K., Monk, A., Wedel, N., & Gradwell, E. (2010) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2010.09.014 · Cited by 306
Meal-Related Structured Self-Monitoring of Blood Glucose
Schwedes, U., Siebolds, M., Mertes, G., & For the SMBG Study Group (2002) · Diabetes Care · doi:10.2337/diacare.25.11.1928 · Cited by 300
Effectiveness of disease-management programs for improving diabetes care: a meta-analysis
Pimouguet, C., Le Goff, M., Thiebaut, R., Dartigues, J. F., & Helmer, C. (2011) · Canadian Medical Association Journal · doi:10.1503/cmaj.091786 · Cited by 285
Martin, S., Schneider, B., Heinemann, L., Lodwig, V., Kurth, H.-J., Kolb, H., Scherbaum, W. A., & for the ROSSO Study Group (2006) · Diabetologia · doi:10.1007/s00125-005-0083-5 · Cited by 284
Self-monitoring of blood glucose in type 2 diabetes: systematic review
Clar, C., Barnard, K., Cummins, E., Royle, P., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14120 · Cited by 274
“29 Consideration needs to be given to identifying those patients who would benefit from SMBG both biomedically in terms of glycaemic control and psychosocially in terms of improved QoL. However, the key may be to not only identify these patients, but also have a supportive HCP who supports them in self-management and…”
Simon, J., Gray, A., Clarke, P., Wade, A., Neil, A., & Farmer, A. (2008) · BMJ · doi:10.1136/bmj.39526.674873.be · Cited by 206
Peel, E., Douglas, M., & Lawton, J. (2007) · BMJ · doi:10.1136/bmj.39302.444572.de · Cited by 203
“Despite the lack of conclusive evidence of an association between self monitoring of blood glucose and glycaemic control (even in large scale observational studies with heterogeneous groups of patients”
BackgroundSerum 1,5-Anhydroglucitol (GlycoMark™): A Short-Term Glycemic Marker
Buse, J. B., Freeman, J. L. R., Edelman, S. V., Jovanovic, L., & McGill, J. B. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503765691839 · Cited by 187
Davidson, M. B., Castellanos, M., Kain, D., & Duran, P. (2005) · The American Journal of Medicine · doi:10.1016/j.amjmed.2004.12.006 · Cited by 178
Jr., J. N. S., Jr., N. A. N., Tan, K. M., & Grava, M. B. (2005) · Current Medical Research and Opinion · doi:10.1185/030079904x20286 · Cited by 177
Longitudinal study of new and prevalent use of self-monitoring of blood glucose
Karter, A. J., Parker, M. M., Moffet, H. H., Spence, M. M., Chan, J., Ettner, S. L., & Selby, J. V. (2006) · Diabetes Care · doi:10.2337/dc06-2073 · Cited by 139
Skeie, S., Thue, G., Nerhus, K., & Sandberg, S. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.7.994 · Cited by 131
“n (%) 9 ( 6 ) 31 (12) No. of years using instrumenta 1 11 1”
Poolsup, N., Suksomboon, N., & Rattanasookchit, S. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0091 · Cited by 127
Allemann, S., Houriet, C., Diem, P., & Stettler, C. (2009) · Current Medical Research and Opinion · doi:10.1185/03007990903364665 · Cited by 115
Barnett, A. H., Krentz, A. J., Strojek, K., Sieradzki, J., Azizi, F., Embong, M., Imamoglu, S., Perušičová, J., Uličiansky, V., & Winkler, G. (2008) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2008.00894.x · Cited by 106
“To provide a more clearly defined answer to the question of whether patients with type 2 diabetes not receiving insulin should monitor their blood glucose levels, there have been a number of calls for an adequately powered, prospective, randomized, controlled trial [10,12, 13 ,23,24].”
BackgroundValue of Self-Monitoring Blood Glucose Pattern Analysis in Improving Diabetes Outcomes
Parkin, C. G., & Davidson, J. A. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300314 · Cited by 96
Health Technologies for Monitoring and Managing Diabetes: A Systematic Review
Russell-Minda, E., Jutai, J., Speechley, M., Bradley, K., Chudyk, A., & Petrella, R. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300628 · Cited by 92
Berard, L. D., Siemens, R., & Woo, V. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2017.10.007 · Cited by 69
Machry, R. V., Rados, D. V., Gregório, G. R. D., & Rodrigues, T. C. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2018.05.037 · Cited by 55
Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin
Welschen, L. M., Bloemendal, E., Nijpels, G., Dekker, J. M., Heine, R. J., Stalman, W. A., & Bouter, L. M. (2005) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005060.pub2 · Cited by 51
B. Davidson, M. (2010) · Reviews on Recent Clinical Trials · doi:10.2174/157488710792007248 · Cited by 15
“I have followed the literature on SMBG in non-insulin treated diabetic patients for many years and have identified 14 RCTs evaluating its effect on Hb A1c levels in this cohort (Table 1) Nine studies showed no difference between patients who performed SMBG compared to those who did not [57,9,11,12,15-17]; five of them…”
BackgroundMethod
Metadata
- Authors
- Coster, S., Gulliford, M. C., Seed, P. T., Powrie, J. K., & Swaminathan, R.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2000-11
- Volume
- 17
- Issue
- 11
- Pages
- 755-761
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W2157159336
- Cited by
- 177
- References
- 25
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.