Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 568

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A screening program for trisomy 21 at 10–14 weeks using fetal nuchal translucency, maternal serum free β‐human chorionic gonadotropin and pregnancy‐associated plasma protein‐A

Spencer, K., Souter, V., Tul, N., Snijders, R., Nicolaides, K. H.·1999·Ultrasound in Obstetrics & Gynecology

Abstract

Objective: To examine the potential impact of combining maternal age with fetal nuchal translucency thickness and maternal serum free β‐human chorionic gonadotropin (β‐hCG) and pregnancy‐associated plasma protein‐A (PAPP‐A) in screening for trisomy 21 at 10–14 weeks of gestation. Methods: Maternal serum free β‐hCG and PAPP‐A were measured by Kryptor, a random access immunoassay analyzer using time‐resolved amplified cryptate emission, in 210 singleton pregnancies with trisomy 21 and 946 chromosomally normal controls, matched for maternal age, gestation and sample storage time. In all cases the fetal crown–rump length and nuchal translucency thickness had been measured by ultrasonography at 10–14 weeks of gestation and maternal blood had been obtained at the time of the scan. The distributions (in multiples of the median; MoM) of free β‐hCG and PAPP‐A (corrected for maternal weight) and fetal nuchal translucency (NT) were determined in the trisomy 21 group and the controls. Likelihood ratios for the various marker combinations were calculated and these were used together with the age‐related risk for trisomy 21 in the first trimester to calculate the expected detection rate of affected pregnancies, at a fixed false‐positive rate, in a population with the maternal age distribution of pregnancies in England and Wales. Results: In a population with the maternal age distribution of pregnancies in England and Wales, it was estimated that, using the combination of maternal age, fetal nuchal translucency thickness and maternal serum free ß‐hCG and PAPP‐A, the detection of trisomy 21 pregnancies would be 89% at a fixed false‐positive rate of 5%. Alternatively, at a fixed detection rate of 70%, the false‐positive rate would be 1%. The inclusion of biochemical parameters added an additional 16% to the detection rate obtained using NT and maternal age alone. Conclusions: Rapid diagnostic technology like Kryptor, which can provide automated reproducible biochemical measurements within 30 min of obtaining a blood sample, will allow the development of interdisciplinary one‐stop clinics for early fetal assessment. Such clinics will be able to deliver improved screening sensitivity, rapidly and more efficiently, leading to reduced patient anxiety and stress. Copyright © 1999 International Society of Ultrasound in Obstetrics and Gynecology

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1469-0705.1999.13040231.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 568

Metadata

Authors
Spencer, K., Souter, V., Tul, N., Snijders, R., & Nicolaides, K. H.
Venue
Ultrasound in Obstetrics & Gynecology
Publisher
Wiley
Published
1999-04
Volume
13
Issue
4
Pages
231-237
ISSN
  • 0960-7692 (ISSN-L)
  • 1469-0705
OpenAlex
W2142091369
Cited by
568
References
1
FWCI
35.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A screening program for trisomy 21 at 10–14 weeks using fetal nuchal translucency, maternal serum free β‐human chorionic gonadotropin and pregnancy‐associated plasma protein‐A. https://app.cochat.ai/papers/10.1046/j.1469-0705.1999.13040231.x
The paper
Spencer, K., Souter, V., Tul, N., Snijders, R., & Nicolaides, K. H. (1999). A screening program for trisomy 21 at 10–14 weeks using fetal nuchal translucency, maternal serum free β‐human chorionic gonadotropin and pregnancy‐associated plasma protein‐A. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1046/j.1469-0705.1999.13040231.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.