Rapid Changes in Local Extracellular Rat Brain Glucose Observed with an In Vivo Glucose Sensor
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
A needle‐type electrochemically based microsensor for glucose (110 µm o.d.) is described. This sensor, designed for monitoring transient glucose content changes in response to neural stimuli, has a response time of ∼5 s and has been shown to be free of interference from endogenous electroactive species such as ascorbate, urate, and various neurotransmitters. It exhibits linear response to glucose up to 10 m M. The usefulness of the sensor has been demonstrated by examining the time‐dependent interstitial glucose concentration in the rat hippocampus in response to KCl depolarization and by stimulation of glutamate neurons through a perforant pathway. Simultaneous monitoring of oxygen is also carried out and demonstrates that for both oxygen and glucose there is substantial local depletion of both species and that their pools are replenished by increased regional cerebral blood flow. The transient initial rapid (10–13 s) decrease up to 20–34%, observed on a time scale comparable to that for neurotransmitter release, may be involved in a recently suggested astrocytic uptake for glutamate‐stimulated aerobic glycolysis possibly needed to meet energy homeostasis in brain. These studies demonstrate the importance of microsensors in monitoring transient events linked to neuronal stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pellerin, L., & Magistretti, P. J. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.22.10625 · Cited by 2,927
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
Siesjö, B. K. (1978) · Medical Entomology and Zoology · Cited by 1,437
Microdialysis—Theory and application
Benveniste, H., & Hüttemeier, P. C. (1990) · Progress in Neurobiology · doi:10.1016/0301-0082(90)90027-e · Cited by 646
Sokoloff, L. (1981) · PubMed · Cited by 479
Transport of glucose from blood to brain.
Lund-Andersen, H. (1979) · Physiological Reviews · doi:10.1152/physrev.1979.59.2.305 · Cited by 474 · cited 1×
“Glucose utilization within the brain has long been believed to be limited by phosphorylation, not transport (Cremer et al., 1979; Lund-Andersen, 1979).”
BackgroundFacilitated transfer of glucose from blood into brain tissue.
Crone, C. (1965) · The Journal of Physiology · doi:10.1113/jphysiol.1965.sp007748 · Cited by 442 · cited 1×
“Brain glucose is transported across the blood—brain barrier (BBB) by a saturable process of facilitated diffusion (Crone, 1965; Buschiazzo et al., 1970).”
BackgroundGrünewald, R. A. (1993) · Brain Research Reviews · doi:10.1016/0165-0173(93)90010-w · Cited by 293
Hu, Y., Mitchell, K. M., Albahadily, F. N., Michaelis, E. K., & Wilson, G. S. (1994) · Brain Research · doi:10.1016/0006-8993(94)90870-2 · Cited by 252
Self-citationO'Neill, R. D., Fillenz, M., Sundström, L., & Rawlins, J. N. P. (1984) · Neuroscience Letters · doi:10.1016/0304-3940(84)90166-6 · Cited by 117
In vivo voltammetry: Some methodological considerations
Stamford, J. A. (1986) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(86)90031-2 · Cited by 87
An amperometric enzyme electrode for monitoring brain glucose in the freely moving rat
Boutelle, M. G., Stanford, S. C., Fillenz, M., Albery, W. J., & Bartlett, P. (1986) · Neuroscience Letters · doi:10.1016/0304-3940(86)90527-6 · Cited by 77
Santoro, A. (1995) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/10.5.615 · Cited by 72
Astrocytes and the delivery of glucose from plasma to neurons
Forsyth, R. J. (1996) · Neurochemistry International · doi:10.1016/0197-0186(95)00094-1 · Cited by 64
Cellular Microenvironment in Relation to Local Blood Flow
Silver, I. A. (1978) · Novartis Foundation symposium · doi:10.1002/9780470720370.ch5 · Cited by 49
Modification of the sensitivity of glucose sensor implanted into subcutaneous tissue.
Thomé-Duret, V., Gangnerau, M.-N., Zhang, Y., Wilson, G. S., & Reach, G. (1996) · PubMed · Cited by 42
Self-citationTransport of essential nutrients across the blood-brain barrier of individual structures.
Hawkins, R. A. (1986) · PubMed · Cited by 30
Cited by
Cellular mechanisms of brain energy metabolism and their relevance to functional brain imaging
Magistretti, P. J., & Pellerin, L. (1999) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1999.0471 · Cited by 749
Monitoring Rapid Chemical Communication in the Brain
Robinson, D. L., Hermans, A., Seipel, A. T., & Wightman, R. M. (2008) · Chemical Reviews · doi:10.1021/cr068081q · Cited by 669
CNS energy metabolism as related to function
Ames, A. (2000) · Brain Research Reviews · doi:10.1016/s0165-0173(00)00038-2 · Cited by 663
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Self-citationBrain lactate metabolism: the discoveries and the controversies
Dienel, G. A. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.175 · Cited by 479
Metadata
- Authors
- Hu, Y., & Wilson, G. S.
- Venue
- Journal of Neurochemistry
- Publisher
- Wiley
- Published
- 1997-04
- Volume
- 68
- Issue
- 4
- Pages
- 1745-1752
- ISSN
- 0022-3042 (ISSN-L)
- 1471-4159
- OpenAlex
- W2046235838
- Cited by
- 186
- References
- 17
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.