CoChat

Enhanced, Simplified Glucose Sensors: Long‐Term Clinical Application of Wearable Artificial Endocrine Pancreas

Shichiri, Motoaki, Sakakida, Michiharu, Nishida, Kenro, Shimoda, Seiya · 1998 · Artificial Organs
Cited by 66

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

At present, 2 major problems should be solved before long‐term application of the wearable artificial endocrine pancreas, the development of a reliable and stable glucose monitoring system and the development of a subcutaneous insulin infusion algorithm. With either a miniaturized extracorporeal glucose monitoring system based on microdialysis sampling method or a ferrocene‐mediated needle‐type glucose sensor covered with highly biocompatible membrane, poly(2‐methacryloyloxyethyl phosphorylcholine‐co‐n‐butyl methacrylate) (poly[MPC‐co‐BMA]) membrane, subcutaneous glucose concentrations could be monitored for 7 days without any in vivo calibrations, followed by 14 days with one point calibration. Considering the management and safety of the insulin delivery route, subcutaneous insulin infusion is obligatory. With the subcutaneous insulin infusion algorithm using a short acting insulin analogue (Insulin Lispro), near physiological glycemic control could be established in diabetic patients without showing any delayed hyperinsulinemia or hypoglycemia. The wearable artificial endocrine pancreas is now recognized as an excellent therapeutic tool for regulating blood glucose excursions physiologically in ambulatory diabetic patients on a long‐term basis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1525-1594.1998.06043.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 66

Metadata

Authors
Shichiri, M., Sakakida, M., Nishida, K., & Shimoda, S.
Venue
Artificial Organs
Publisher
Wiley
Published
1998-01
Volume
22
Issue
1
Pages
32-42
ISSN
  • 0160-564X (ISSN-L)
  • 1525-1594
OpenAlex
W2046688803
Cited by
66
References
1
FWCI
3.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enhanced, Simplified Glucose Sensors: Long‐Term Clinical Application of Wearable Artificial Endocrine Pancreas. https://app.cochat.ai/papers/10.1046/j.1525-1594.1998.06043.x
The paper
Shichiri, M., Sakakida, M., Nishida, K., & Shimoda, S. (1998). Enhanced, Simplified Glucose Sensors: Long‐Term Clinical Application of Wearable Artificial Endocrine Pancreas. Artificial Organs. https://doi.org/10.1046/j.1525-1594.1998.06043.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.