fMRI Activation in Continuous and Spike‐triggered EEG–fMRI Studies of Epileptic Spikes
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Summary: Purpose: To evaluate functional magnetic resonance imaging (fMRI) with simultaneous EEG for finding metabolic sources of epileptic spikes. To find the localizing value of activated regions and factors influencing fMRI responses. Methods: Patients with focal epilepsy and frequent spikes were subjected to spike‐triggered or continuous fMRI with simultaneous EEG. Results were analyzed in terms of fMRI activation, concordance with the location of EEG spiking and anatomic MRI abnormalities, and other EEG and clinical variables. In four patients, results also were compared with those of intracerebral EEG. Results: Forty‐eight studies were performed on 38 patients. Seventeen studies were not analyzed, primarily because no spikes occurred during scanning. Activation was obtained in 39% of 31 studies, with an activation volume of 2.55 ± 4.84 cc. Activated regions were concordant with EEG localization in almost all studies and confirmed by intracerebral EEG in four patients. Forty percent of patients without an MRI lesion showed activation; 37.5% of patients with a lesion had an activation; the activation was near or inside the lesion. Bursts of spikes were more likely to generate an fMRI response than were isolated spikes (76 vs. 11%; p < 0.05). Conclusions: Combining EEG and fMRI in focal epilepsy yields regions of activation that are presumably the source of spiking activity. These regions are highly linked with epileptic foci and epileptogenic lesions in a significant number of patients. Activation also is found in patients with no visible MRI lesion. Intracerebral recordings largely confirm that these activation regions represent epileptogenic areas. It is still unclear why many patients show no activation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483 · cited 2×
“The fMRI signal is caused by disproportionate changes in blood volume and deoxyhemoglobin concentration in the venous bed at or near the site of neuronal activation (4).”
BackgroundA Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI
Allen, P. J., Josephs, O., & Turner, R. (2000) · NeuroImage · doi:10.1006/nimg.2000.0599 · Cited by 1,301
Diffusion weighted fMRI at 1.5 T
Song, A. W., Wong, E. C., Tan, S. G., & Hyde, J. S. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350204 · Cited by 208 · cited 1×
“ca nomenon is thought to be less than 1cm (5).”
Background
Cited by
Intracranial EEG Substrates of Scalp EEG Interictal Spikes
Tao, J. X., Ray, A., Hawes‐Ebersole, S., & Ebersole, J. S. (2005) · Epilepsia · doi:10.1111/j.1528-1167.2005.11404.x · Cited by 424
Frontal theta EEG activity correlates negatively with the default mode network in resting state
Scheeringa, R., Bastiaansen, M. C. M., Petersson, K. M., Oostenveld, R., Norris, D. G., & Hagoort, P. (2008) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2007.05.017 · Cited by 400
“The EEG data were corrected for gradient and pulse artifacts along the lines described by Allen et al. (1998, 2000) using Vision Analyzer (Brainproducts).”
BackgroundMethodfMRI activation during spike and wave discharges in idiopathic generalized epilepsy
Aghakhani, Y. (2004) · Brain · doi:10.1093/brain/awh136 · Cited by 398
Correlating the alpha rhythm to BOLD using simultaneous EEG/fMRI: Inter-subject variability
Gonçalves, S. I., de Munck, J. C., Pouwels, P. J. W., Schoonhoven, R., Kuijer, J. P. A., Maurits, N. M., Hoogduin, J. M., Van Someren, E. J. W., Heethaar, R. M., & Lopes da Silva, F. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.09.062 · Cited by 356
Salek-Haddadi, A., Diehl, B., Hamandi, K., Merschhemke, M., Liston, A., Friston, K., Duncan, J. S., Fish, D. R., & Lemieux, L. (2006) · Brain Research · doi:10.1016/j.brainres.2006.02.098 · Cited by 280
Combining EEG and fMRI: A multimodal tool for epilepsy research
Gotman, J., Kobayashi, E., Bagshaw, A. P., Bénar, C., & Dubeau, F. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20577 · Cited by 280
Self-citationEEG–fMRI of idiopathic and secondarily generalized epilepsies
Hamandi, K., Salek-Haddadi, A., Laufs, H., Liston, A., Friston, K., Fish, D. R., Duncan, J. S., & Lemieux, L. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.016 · Cited by 274
EEG-fMRI in the preoperative work-up for epilepsy surgery
Zijlmans, M., Huiskamp, G., Hersevoort, M., Seppenwoolde, J.-H., van Huffelen, A. C., & Leijten, F. S. S. (2007) · Brain · doi:10.1093/brain/awm141 · Cited by 256
Evaluation of EEG localization methods using realistic simulations of interictal spikes
Grova, C., Daunizeau, J., Lina, J.-M., Bénar, C. G., Benali, H., & Gotman, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.053 · Cited by 233
Self-citationBagshaw, A. P., Aghakhani, Y., Bénar, C., Kobayashi, E., Hawco, C., Dubeau, F., Pike, G. B., & Gotman, J. (2004) · Human Brain Mapping · doi:10.1002/hbm.20024 · Cited by 227
Self-citationEEG–fMRI of epileptic spikes: Concordance with EEG source localization and intracranial EEG
Bénar, C.-G., Grova, C., Kobayashi, E., Bagshaw, A. P., Aghakhani, Y., Dubeau, F., & Gotman, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.008 · Cited by 179
Self-citationElectrophysiological correlates of the BOLD signal for EEG-informed fMRI
Murta, T., Leite, M., Carmichael, D. W., Figueiredo, P., & Lemieux, L. (2015) · Human Brain Mapping · doi:10.1002/hbm.22623 · Cited by 165
“The group found that frequency-weighted metrics yielded higher number of voxels exhibiting statistically significant BOLD changes, when compared to power-weighted metrics or to the conventional boxcar-based regression, in line with the heuristic proposed by Kilner et al. [2005].”
Metadata
- Authors
- Al‐Asmi, A., Bénar, C., Gross, D. W., Khani, Y. A., Andermann, F., Pike, B., Dubeau, F., & Gotman, J.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2003-09-22
- Volume
- 44
- Issue
- 10
- Pages
- 1328-1339
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W1592963603
- Cited by
- 203
- References
- 3
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.