Gene Delivery Using Ultrasound Contrast Agents
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
With the human genome product and continuing advances in molecular biology many therapeutic genes have been discovered. In the cardiovascular system, gene therapy has the potential to improve myocardial vascularization and ameliorate congestive heart failure. For successful development of clinical gene therapy, however, effective gene delivery vectors are needed. Ultrasound contrast agents can be used to develop new, more effective vectors for gene delivery. Ultrasound contrast agents lower the threshold for cavitation by ultrasound energy. Using physical properties of microbubbles and coating materials, genetic drugs have been incorporated into ultrasound contrast agents. Genebearing microbubbles can be injected IV and ultrasound energy applied to the target region. As the microbubbles enter the region of insonation, the microbubbles cavitate, locally releasing DNA. Cavitation also likely causes a local shockwave that improves cellular uptake of DNA. With transthoracic ultrasound, using commercially available diagnostic ultrasound system and an IV injection of gene‐bearing microbubbles, high levels of transgene expression are observed in the insonated region of the myocardium. This new technology using microbubbles and ultrasound for gene delivery merits further study and development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fischer, D., Bieber, T., Li, Y., Elsässer, H.-P., & Kissel, T. (1999) · Pharmaceutical Research · doi:10.1023/a:1014861900478 · Cited by 1,217
Baumgartner, I., Pieczek, A., Manor, O., Blair, R., Kearney, M., Walsh, K., & Isner, J. M. (1998) · Circulation · doi:10.1161/01.cir.97.12.1114 · Cited by 1,098
von der Leyen, H. E., Gibbons, G. H., Morishita, R., Lewis, N. P., Zhang, L., Nakajima, M., Kaneda, Y., Cooke, J. P., & Dzau, V. J. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.4.1137 · Cited by 762
Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound
Apfel, R. E., & Holland, C. K. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90125-g · Cited by 690
Metabolic instability of plasmid DNA in the cytosol: a potential barrier to gene transfer
Lechardeur, D., Sohn, K.-J., Haardt, M., Joshi, P. B., Monck, M., Graham, R. W., Beatty, B., Squire, J., O’Brodovich, H., & Lukacs, G. L. (1999) · Gene Therapy · doi:10.1038/sj.gt.3300867 · Cited by 633
A review of in vitro bioeffects of inertial ultrasonic cavitation from a mechanistic perspective
Miller, M. W., Miller, D. L., & Brayman, A. A. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00089-0 · Cited by 528
Skyba, D. M., Price, R. J., Linka, A. Z., Skalak, T. C., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.98.4.290 · Cited by 474
Price, R. J., Skyba, D. M., Kaul, S., & Skalak, T. C. (1998) · Circulation · doi:10.1161/01.cir.98.13.1264 · Cited by 393
Witzenbichler, B., Asahara, T., Murohara, T., Silver, M., Spyridopoulos, I., Magner, M., Principe, N., Kearney, M., Hu, J.-S., & Isner, J. M. (1998) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)65582-4 · Cited by 346
Liu, D. (2004) · Dalian Minzu Xueyuan xuebao · Cited by 326
Acoustically Active Lipospheres Containing Paclitaxel: A New Therapeutic Ultrasound Contrast Agent
UNGER, E. C., McCREERY, T. P., SWEITZER, R. H., CALDWELL, V. E., & WU, Y. (1998) · Investigative Radiology · doi:10.1097/00004424-199812000-00007 · Cited by 267
Self-citationA novel potent strategy for gene delivery using a single peptide vector as a carrier
Morris, M. C., Chaloin, L., Mery, J., Heitz, F., & Divita, G. (1999) · Nucleic Acids Research · doi:10.1093/nar/27.17.3510 · Cited by 182
Ultrasound Enhances Gene Expression of Liposomal Transfection
UNGER, E. C., McCREERY, T. P., & SWEITZER, R. H. (1997) · INVESTIGATIVE RADIOLOGY · doi:10.1097/00004424-199712000-00001 · Cited by 160
Self-citationSelective gene delivery to head and neck cancer cells via an integrin targeted adenoviral vector.
Kasono, K., Blackwell, J. L., Douglas, J. T., Dmitriev, I. P., Strong, T. V., Reynolds, P. N., Kropf, D. A., Carroll, W. R., Peters, G. E., Bucy, R. P., et al. (1999) · PubMed · Cited by 133
Progress in Adeno-Associated Virus Type 2 Vector Production: Promises and Prospects for Clinical Use
Grimm, D., & Kleinschmidt, J. A. (1999) · Human Gene Therapy · doi:10.1089/10430349950016799 · Cited by 123
Inflammatory responses following direct injection of plasmid DNA into skeletal muscle
McMahon, J. M., Wells, K., Bamfo, J., Cartwright, M., & Wells, D. J. (1998) · Gene Therapy · doi:10.1038/sj.gt.3300718 · Cited by 106
Gene therapy for myocardial angiogenesis
Losordo, D. W., Vale, P. R., & Isner, J. M. (1999) · American Heart Journal · doi:10.1016/s0002-8703(99)70333-9 · Cited by 100
Mendiratta, S. K., Quezada, A., Matar, M. M., Wang, J., Hebel, H. L., Long, S., Nordstrom, J. L., & Pericle, F. (1999) · Gene Therapy · doi:10.1038/sj.gt.3300891 · Cited by 73
Phase I Clinical Trials of MRX-115: A New Ultrasound Contrast Agent
Fritz, T., Unger, E. C., SUTHERLAND, G., & Sahn, D. J. (1997) · Investigative Radiology · doi:10.1097/00004424-199712000-00003 · Cited by 70
Self-citationBroillet, A., Puginier, J., VENTRONE, R., & SCHNEIDER, M. (1998) · Investigative Radiology · doi:10.1097/00004424-199804000-00003 · Cited by 67
Regulated expression of a foreign gene targeted to the ischaemic myocardium
Prentice, H. (1997) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00158-2 · Cited by 59
Anwer, K., Shi, M., French, M. F., Muller, S. R., Chen, W., Liu, Q., Proctor, B., Wang, J., Mumper, R. J., Singhal, A. K., et al. (1998) · Human Gene Therapy · doi:10.1089/hum.1998.9.5-659 · Cited by 57
Srinivasakumar, N., & Schuening, F. (1999) · Journal of Virology · doi:10.1128/jvi.73.11.9589-9598.1999 · Cited by 43
Molecular biology and gene transfer in atherosclerosis in the stenting era
Caplice, N. M., Simari, R. D., & Holmes, D. R. (1999) · International Journal of Cardiovascular Interventions · doi:10.1080/acc.2.3.141.152 · Cited by 3
Cited by
Gene Therapy Progress and Prospects: Nonviral vectors
Niidome, T., & Huang, L. (2002) · Gene Therapy · doi:10.1038/sj.gt.3301923 · Cited by 963
Therapeutic applications of lipid-coated microbubbles
Unger, E. C., Porter, T., Culp, W., Labell, R., Matsunaga, T., & Zutshi, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.12.006 · Cited by 591
Self-citationMultifunctional and stimuli-sensitive pharmaceutical nanocarriers
Torchilin, V. (2009) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.09.026 · Cited by 583
“There already exist the whole set of promising data on drug and gene delivery by ultrasound-sensitive drug carriers, some of which are reviewed in [186-188].”
BackgroundMechanical Bioeffects of Ultrasound
Dalecki, D. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140126 · Cited by 564
Controlled and targeted tumor chemotherapy by ultrasound-activated nanoemulsions/microbubbles
Rapoport, N. Y., Kennedy, A. M., Shea, J. E., Scaife, C. L., & Nam, K.-H. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.05.026 · Cited by 551
Metadata
- Authors
- Unger, E. C., Hersh, E., Vannan, M., & McCreery, T.
- Venue
- Echocardiography
- Publisher
- Wiley
- Published
- 2001-05
- Volume
- 18
- Issue
- 4
- Pages
- 355-361
- ISSN
- 0742-2822 (ISSN-L)
- 1540-8175
- OpenAlex
- W2009082552
- Cited by
- 170
- References
- 24
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.