Gene Delivery Using Ultrasound Contrast Agents
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
With the human genome product and continuing advances in molecular biology many therapeutic genes have been discovered. In the cardiovascular system, gene therapy has the potential to improve myocardial vascularization and ameliorate congestive heart failure. For successful development of clinical gene therapy, however, effective gene delivery vectors are needed. Ultrasound contrast agents can be used to develop new, more effective vectors for gene delivery. Ultrasound contrast agents lower the threshold for cavitation by ultrasound energy. Using physical properties of microbubbles and coating materials, genetic drugs have been incorporated into ultrasound contrast agents. Genebearing microbubbles can be injected IV and ultrasound energy applied to the target region. As the microbubbles enter the region of insonation, the microbubbles cavitate, locally releasing DNA. Cavitation also likely causes a local shockwave that improves cellular uptake of DNA. With transthoracic ultrasound, using commercially available diagnostic ultrasound system and an IV injection of gene‐bearing microbubbles, high levels of transgene expression are observed in the insonated region of the myocardium. This new technology using microbubbles and ultrasound for gene delivery merits further study and development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fischer, D., Bieber, T., Li, Y., Elsässer, H.-P., & Kissel, T. (1999) · Pharmaceutical Research · doi:10.1023/a:1014861900478 · Cited by 1,217
Baumgartner, I., Pieczek, A., Manor, O., Blair, R., Kearney, M., Walsh, K., & Isner, J. M. (1998) · Circulation · doi:10.1161/01.cir.97.12.1114 · Cited by 1,098
von der Leyen, H. E., Gibbons, G. H., Morishita, R., Lewis, N. P., Zhang, L., Nakajima, M., Kaneda, Y., Cooke, J. P., & Dzau, V. J. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.4.1137 · Cited by 762
Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound
Apfel, R. E., & Holland, C. K. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90125-g · Cited by 690
Metabolic instability of plasmid DNA in the cytosol: a potential barrier to gene transfer
Lechardeur, D., Sohn, K.-J., Haardt, M., Joshi, P. B., Monck, M., Graham, R. W., Beatty, B., Squire, J., O’Brodovich, H., & Lukacs, G. L. (1999) · Gene Therapy · doi:10.1038/sj.gt.3300867 · Cited by 633
A review of in vitro bioeffects of inertial ultrasonic cavitation from a mechanistic perspective
Miller, M. W., Miller, D. L., & Brayman, A. A. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00089-0 · Cited by 528
Skyba, D. M., Price, R. J., Linka, A. Z., Skalak, T. C., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.98.4.290 · Cited by 474
Price, R. J., Skyba, D. M., Kaul, S., & Skalak, T. C. (1998) · Circulation · doi:10.1161/01.cir.98.13.1264 · Cited by 393
Witzenbichler, B., Asahara, T., Murohara, T., Silver, M., Spyridopoulos, I., Magner, M., Principe, N., Kearney, M., Hu, J.-S., & Isner, J. M. (1998) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)65582-4 · Cited by 346
Liu, D. (2004) · Dalian Minzu Xueyuan xuebao · Cited by 326
Cited by
Gene Therapy Progress and Prospects: Nonviral vectors
Niidome, T., & Huang, L. (2002) · Gene Therapy · doi:10.1038/sj.gt.3301923 · Cited by 963
Therapeutic applications of lipid-coated microbubbles
Unger, E. C., Porter, T., Culp, W., Labell, R., Matsunaga, T., & Zutshi, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.12.006 · Cited by 591
Self-citationMultifunctional and stimuli-sensitive pharmaceutical nanocarriers
Torchilin, V. (2009) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.09.026 · Cited by 583
“There already exist the whole set of promising data on drug and gene delivery by ultrasound-sensitive drug carriers, some of which are reviewed in [186-188].”
BackgroundMechanical Bioeffects of Ultrasound
Dalecki, D. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140126 · Cited by 564
Controlled and targeted tumor chemotherapy by ultrasound-activated nanoemulsions/microbubbles
Rapoport, N. Y., Kennedy, A. M., Shea, J. E., Scaife, C. L., & Nam, K.-H. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.05.026 · Cited by 551
Ultrasound, cavitation bubbles and their interaction with cells
Wu, J., & Nyborg, W. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.009 · Cited by 544
Ultrasound mediated delivery of drugs and genes to solid tumors
Frenkel, V. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.007 · Cited by 474
Micelles and nanoparticles for ultrasonic drug and gene delivery
Husseini, G. A., & Pitt, W. G. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.008 · Cited by 468
Klibanov, A. L. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000199292.88189.0f · Cited by 424
Rapoport, N., Nam, K.-H., Gupta, R., Gao, Z., Mohan, P., Payne, A., Todd, N., Liu, X., Kim, T., Shea, J., et al. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.01.022 · Cited by 423
Physical methods for gene transfer: Improving the kinetics of gene delivery into cells
MEHIERHUMBERT, S., & GUY, R. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.12.007 · Cited by 395
Karshafian, R., Bevan, P. D., Williams, R., Samac, S., & Burns, P. N. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.10.013 · Cited by 355
Lan, H. Y., Mu, W., Tomita, N., Huang, X. R., Li, J. H., Zhu, H.-J., Morishita, R., & Johnson, R. J. (2003) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000067632.04658.b8 · Cited by 344
Borden, M. A., & Longo, M. L. (2002) · Langmuir · doi:10.1021/la026082h · Cited by 340
Mohan, P., & Rapoport, N. (2010) · Molecular Pharmaceutics · doi:10.1021/mp100269f · Cited by 331
Bekeredjian, R., Chen, S., Frenkel, P. A., Grayburn, P. A., & Shohet, R. V. (2003) · Circulation · doi:10.1161/01.cir.0000084535.35435.ae · Cited by 321
Encapsulated ultrasound microbubbles: Therapeutic application in drug/gene delivery
Liu, Y., Miyoshi, H., & Nakamura, M. (2006) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.05.018 · Cited by 319
Pharmaceutical Strategies Utilizing Recombinant Human Serum Albumin
Tuan Giam Chuang, V., Kragh-Hansen, U., & Otagiri, M. (2002) · Pharmaceutical Research · doi:10.1023/a:1015396825274 · Cited by 295
Drug loaded microbubble design for ultrasound triggered delivery
Lentacker, I., De Smedt, S. C., & Sanders, N. N. (2009) · Soft Matter · doi:10.1039/b823051j · Cited by 264
Phase‐shift, stimuli‐responsive perfluorocarbon nanodroplets for drug delivery to cancer
Rapoport, N. (2012) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1176 · Cited by 246
Direct observations of ultrasound microbubble contrast agent interaction with the microvessel wall
Caskey, C. F., Stieger, S. M., Qin, S., Dayton, P. A., & Ferrara, K. W. (2007) · The Journal of the Acoustical Society of America · doi:10.1121/1.2747204 · Cited by 226
MR Imaging–Controlled Focused Ultrasound Ablation: A Noninvasive Image-Guided Surgery
Jolesz, F. A., Hynynen, K., McDannold, N., & Tempany, C. (2005) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2005.04.008 · Cited by 193
Salman, A., Kantor, A., McClements, M. E., Marfany, G., Trigueros, S., & MacLaren, R. E. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14091842 · Cited by 37
Metadata
- Authors
- Unger, E. C., Hersh, E., Vannan, M., & McCreery, T.
- Venue
- Echocardiography
- Publisher
- Wiley
- Published
- 2001-05
- Volume
- 18
- Issue
- 4
- Pages
- 355-361
- ISSN
- 0742-2822 (ISSN-L)
- 1540-8175
- OpenAlex
- W2009082552
- Cited by
- 170
- References
- 24
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.