Abstract
Two methods to fuse a 3D gyroscope with a 3D accelerometer in order to measure rotations are presented. They are compared with a method requiring only a 3D gyroscope and assessed with a reference system. The good reported accuracies make this system suitable for clinical evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ambulatory measurement of 3D knee joint angle
Favre, J., Jolles, B. M., Aissaoui, R., & Aminian, K. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.12.003 · Cited by 316
Self-citationFunctional calibration procedure for 3D knee joint angle description using inertial sensors
Favre, J., Aissaoui, R., Jolles, B. M., de Guise, J. A., & Aminian, K. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.025 · Cited by 301
Self-citationInertial sensor-based knee flexion/extension angle estimation
Cooper, G., Sheret, I., McMillian, L., Siliverdis, K., Sha, N., Hodgins, D., Kenney, L., & Howard, D. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.004 · Cited by 281
Schall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I. (2016) · Ergonomics · doi:10.1080/00140139.2015.1079335 · Cited by 96
Drift Removal for Improving the Accuracy of Gait Parameters Using Wearable Sensor Systems
Takeda, R., Lisco, G., Fujisawa, T., Gastaldi, L., Tohyama, H., & Tadano, S. (2014) · Sensors · doi:10.3390/s141223230 · Cited by 84
“[10] used acceleration data to compensate for drift in the angular velocity data in situations where gravitational acceleration is the only component measured.”
MethodMassé, F., Gonzenbach, R. R., Arami, A., Paraschiv-Ionescu, A., Luft, A. R., & Aminian, K. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0060-2 · Cited by 77
“This procedure enabled to virtually align the sensor frame with the body frame, in order to ensure robustness against sensor misalignment across patients [26].”
MethodSelf-citationMeasurement of Multi-segment Foot Joint Angles During Gait Using a Wearable System
Rouhani, H., Favre, J., Crevoisier, X., & Aminian, K. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4006674 · Cited by 72
Self-citationDuc, C., Salvia, P., Lubansu, A., Feipel, V., & Aminian, K. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.09.002 · Cited by 61
Self-citationErtzgaard, P., Öhberg, F., Gerdle, B., & Grip, H. (2016) · Manual Therapy · doi:10.1016/j.math.2015.09.004 · Cited by 41
Metadata
- Authors
- Favre, J., Jolles, B. M., Siegrist, O., & Aminian, K.
- Venue
- Electronics Letters
- Published
- 2006-05-25
- Volume
- 42
- Issue
- 11
- Pages
- 612-614
- ISSN
- 0013-5194 (ISSN-L)
- 1350-911X
- OpenAlex
- W2163410835
- Cited by
- 158
- References
- 0
- FWCI
- 8.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.