The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Retinal vessel segmentation by improved matched filtering: evaluation on a new high‐resolution fundus image database
Open accessAbstract
Automatic assessment of retinal vessels plays an important role in the diagnosis of various eye, as well as systemic diseases. A public screening is highly desirable for prompt and effective treatment, since such diseases need to be diagnosed at an early stage. Automated and accurate segmentation of the retinal blood vessel tree is one of the challenging tasks in the computer‐aided analysis of fundus images today. We improve the concept of matched filtering, and propose a novel and accurate method for segmenting retinal vessels. Our goal is to be able to segment blood vessels with varying vessel diameters in high‐resolution colour fundus images. All recent authors compare their vessel segmentation results to each other using only low‐resolution retinal image databases. Consequently, we provide a new publicly available high‐resolution fundus image database of healthy and pathological retinas. Our performance evaluation shows that the proposed blood vessel segmentation approach is at least comparable with recent state‐of‐the‐art methods. It outperforms most of them with an accuracy of 95% evaluated on the new database.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398
An introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879
Survey over image thresholding techniques and quantitative performance evaluation
Sankur, B. (2004) · Journal of Electronic Imaging · doi:10.1117/1.1631315 · Cited by 4,583
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Kittler, J., & Illingworth, J. (1986) · Pattern Recognition · doi:10.1016/0031-3203(86)90030-0 · Cited by 2,180
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Blood vessel segmentation methodologies in retinal images – A survey
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.03.009 · Cited by 1,001
Marín, D., Aquino, A., Gegundez-Arias, M. E., & Bravo, J. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2064333 · Cited by 929
Cited by
A Dataset and a Technique for Generalized Nuclear Segmentation for Computational Pathology
Kumar, N., Verma, R., Sharma, S., Bhargava, S., Vahadane, A., & Sethi, A. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2677499 · Cited by 1,126
DUNet: A deformable network for retinal vessel segmentation
Jin, Q., Meng, Z., Pham, T. D., Chen, Q., Wei, L., & Su, R. (2019) · Knowledge-Based Systems · doi:10.1016/j.knosys.2019.04.025 · Cited by 867
Orlando, J. I., Fu, H., Barbosa Breda, J., van Keer, K., Bathula, D. R., Diaz-Pinto, A., Fang, R., Heng, P.-A., Kim, J., Lee, J., et al. (2020) · Medical Image Analysis · doi:10.1016/j.media.2019.101570 · Cited by 855
Robust Vessel Segmentation in Fundus Images
Budai, A., Bock, R., Maier, A., Hornegger, J., & Michelson, G. (2013) · International Journal of Biomedical Imaging · doi:10.1155/2013/154860 · Cited by 642
Self-citationA Cross-Modality Learning Approach for Vessel Segmentation in Retinal Images
Li, Q., Feng, B., Xie, L., Liang, P., Zhang, H., & Wang, T. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2457891 · Cited by 571
Blood vessel segmentation algorithms — Review of methods, datasets and evaluation metrics
Moccia, S., De Momi, E., El Hadji, S., & Mattos, L. S. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.02.001 · Cited by 567
Orlando, J. I., Prokofyeva, E., & Blaschko, M. B. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2535311 · Cited by 503
Robust Retinal Vessel Segmentation via Locally Adaptive Derivative Frames in Orientation Scores
Zhang, J., Dashtbozorg, B., Bekkers, E., Pluim, J. P. W., Duits, R., & ter Haar Romeny, B. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2587062 · Cited by 417
Enhancement of Vascular Structures in3D and 2D Angiographic Images
Jerman, T., Pernus, F., Likar, B., & Spiclin, Z. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2550102 · Cited by 294
Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening
Seoud, L., Hurtut, T., Chelbi, J., Cheriet, F., & Langlois, J. M. P. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2509785 · Cited by 277
Metadata
- Authors
- Odstrcilik, J., Kolar, R., Budai, A., Hornegger, J., Jan, J., Gazarek, J., Kubena, T., Cernosek, P., Svoboda, O., & Angelopoulou, E.
- Venue
- IET Image Processing
- Published
- 2013-06
- Volume
- 7
- Issue
- 4
- Pages
- 373-383
- ISSN
- 1751-9659 (ISSN-L)
- 1751-9667
- OpenAlex
- W2093545979
- Cited by
- 472
- References
- 33
- FWCI
- 13.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.