Enhancement of Vascular Structures in3D and 2D Angiographic Images
Abstract
A number of imaging techniques are being used for diagnosis and treatment of vascular pathologies like stenoses, aneurysms, embolisms, malformations and remodelings, which may affect a wide range of anatomical sites. For computer-aided detection and highlighting of potential sites of pathology or to improve visualization and segmentation, angiographic images are often enhanced by Hessian based filters. These filters aim to indicate elongated and/or rounded structures by an enhancement function based on Hessian eigenvalues. However, established enhancement functions generally produce a response, which exhibits deficiencies such as poor and non-uniform response for vessels of different sizes and varying contrast, at bifurcations and aneurysms. This may compromise subsequent analysis of the enhanced images. This paper has three important contributions: i) reviews several established enhancement functions and elaborates their deficiencies, ii) proposes a novel enhancement function, which overcomes the deficiencies of the established functions, and iii) quantitatively evaluates and compares the novel and the established enhancement functions on clinical image datasets of the lung, cerebral and fundus vasculatures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Blood vessel segmentation methodologies in retinal images – A survey
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.03.009 · Cited by 1,001
A review of 3D vessel lumen segmentation techniques: Models, features and extraction schemes
Lesage, D., Angelini, E. D., Bloch, I., & Funka-Lea, G. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.07.011 · Cited by 920
Retinal vessel extraction by matched filter with first-order derivative of Gaussian
Zhang, B., Zhang, L., Zhang, L., & Karray, F. (2010) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2010.02.008 · Cited by 505
Odstrcilik, J., Kolar, R., Budai, A., Hornegger, J., Jan, J., Gazarek, J., Kubena, T., Cernosek, P., Svoboda, O., & Angelopoulou, E. (2013) · IET Image Processing · doi:10.1049/iet-ipr.2012.0455 · Cited by 472
Model-Based Detection of Tubular Structures in 3D Images
Krissian, K., Malandain, G., Ayache, N., Vaillant, R., & Trousset, Y. (2000) · Computer Vision and Image Understanding · doi:10.1006/cviu.2000.0866 · Cited by 404
Li, Q., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1581411 · Cited by 349
Tissue classification based on 3D local intensity structures for volume rendering
Sato, Y., Westin, C., Bhalerao, A., Nakajima, S., Shiraga, N., Tamura, S., & Kikinis, R. (2000) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.856997 · Cited by 338
Cited by
Shipley, F. B., Dani, N., Xu, H., Deister, C., Cui, J., Head, J. P., Sadegh, C., Fame, R. M., Shannon, M. L., Flores, V. I., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.08.024 · Cited by 118
Chen, J., Ding, L., Viana, M. P., Lee, H., Sluezwski, M. F., Morris, B., Hendershott, M. C., Yang, R., Mueller, I. A., & Rafelski, S. M. (2018) · doi:10.1101/491035 · Cited by 99
Metadata
- Authors
- Jerman, T., Pernus, F., Likar, B., & Spiclin, Z.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2016-09
- Volume
- 35
- Issue
- 9
- Pages
- 2107-2118
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2334170987
- Cited by
- 294
- References
- 28
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhancement of Vascular Structures in3D and 2D Angiographic Images. https://app.cochat.ai/papers/10.1109/tmi.2016.2550102
- The paper
- Jerman, T., Pernus, F., Likar, B., & Spiclin, Z. (2016). Enhancement of Vascular Structures in3D and 2D Angiographic Images. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2016.2550102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.