Fault diagnosis scheme for open‐circuit faults in field‐oriented control induction motor drives
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In this study, a new model‐based fault detection and isolation (FDI) strategy is proposed for field‐oriented control (FOC) induction motor (IM) drives. Actuator faults are addressed, and specifically, single open‐circuit faults are considered in this study. The residual signals are synthesised by taking the resulting closed‐loop dynamics when a FOC strategy is applied, that is, the residuals are referenced to the synchronous reference frame ( dq e ‐coordinates), which are generated by using a bank of variable structure observers to obtain a robust FDI scheme. Thus, subsystems sensitive to a specific fault, but decoupled from other faults are obtained in a natural way, where only two stator currents and the mechanical position are required for fault isolation purposes. Residual evaluation is carried out in the stator reference frame ( dq ‐coordinates) for the IM model, where the residual direction (angle) is employed to isolate a fault in each one of the six power switches in a voltage source inverter. In addition, the observer FDI scheme can be combined with a fault re‐configuration strategy in order to improve the reliability of the motor drive. Experimental results are illustrated for a three‐phase 3/4 HP IM drive at different reference frequencies and load torques with single open‐circuit faults that verify the ideas presented in this work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Condition Monitoring for Device Reliability in Power Electronic Converters: A Review
Yang, S., Xiang, D., Bryant, A., Mawby, P., Ran, L., & Tavner, P. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2049377 · Cited by 1,278
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Ageing and Failure Modes of IGBT Modules in High-Temperature Power Cycling
Smet, V., Forest, F., Huselstein, J.-J., Richardeau, F., Khatir, Z., Lefebvre, S., & Berkani, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2114313 · Cited by 620
Estima, J. O., & Marques Cardoso, A. J. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188877 · Cited by 377
Fault-Tolerant Voltage Source Inverter for Permanent Magnet Drives
Errabelli, R. R., & Mutschler, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2135866 · Cited by 278
Cited by
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
Jlassi, I., Estima, J. O., Khojet El Khil, S., Mrabet Bellaaj, N., & Marques Cardoso, A. J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2342506 · Cited by 212
“Observer-based approaches for single and simultaneous faults were addressed in [23], [24].”
BackgroundWu, F., & Zhao, J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2587339 · Cited by 82
“Model-based methods are proposed in [19]–[21], these methods are effective, fast and low cost, however, they are poor in robustness and sensitive to parameters.”
MethodFault-Diagnosis and Fault-Tolerant-Control in Industrial Processes and Electrical Drives
Orłowska-Kowalska, T., Kowalski, C. T., & Dybkowski, M. (2017) · Studies in Systems, Decision and Control · doi:10.1007/978-3-319-45735-2_5 · Cited by 21
Metadata
- Authors
- Espinoza‐Trejo, D. R., Campos‐Delgado, D. U., Bossio, G., Bárcenas, E., Hernández‐Díez, J. E., & Lugo‐Cordero, L. F.
- Venue
- IET Power Electronics
- Published
- 2013-05
- Volume
- 6
- Issue
- 5
- Pages
- 869-877
- ISSN
- 1755-4535 (ISSN-L)
- 1755-4543
- OpenAlex
- W2072438027
- Cited by
- 78
- References
- 5
- FWCI
- 4.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.