Protection in DC microgrids: a comparative review
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
A direct current (DC) microgrid has become a superior power system in recent years due to the development of DC loads and higher efficiency of DC systems. One of the challenging problems on DC microgrids operation is protection, and it is still a particular concern associated with the challenges of developing a proper protection scheme owing to its characteristics and lack of standards in DC protection. Due to the significant increasing interest on DC microgrid; this study investigates protection problems and schemes that need to be addressed in modern power systems involving DC microgrids. This study analyses and presents a comprehensive review of the most recent growth in the DC microgrids protection. Additionally, the fault characteristics of DC microgrids, the impact of constant power loads, the protection devices and several proposed methods to overcome the protection problems are discussed. The differences between the proposed protection methods for the DC microgrids are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Electronics: Converters, Applications and Design
Mohan, N., Undeland, T. M., & Robbins, W. P. (1989) · Cited by 4,771
VSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216 · cited 1×
“However, the disadvantage of the IGBTs is that they are unidirectional protection actuators, hence, IGBTs only can clear faults in the DC line and cannot have an impact on the fault on the converter side [92].”
BackgroundHVDC Circuit Breakers: A Review Identifying Future Research Needs
Franck, C. M. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2095889 · Cited by 909
Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790 · cited 5×
“The steady state fault current is obtained by the following equation [14]:”
BackgroundMethodInfluentialProtection of Low-Voltage DC Microgrids
Salomonsson, D., Soder, L., & Sannino, A. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2016622 · Cited by 712
Locating and Isolating DC Faults in Multi-Terminal DC Systems
Tang, L., & Ooi, B.-T. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899276 · Cited by 640
Dynamic Behavior and Stabilization of DC Microgrids With Instantaneous Constant-Power Loads
Kwasinski, A., & Onwuchekwa, C. N. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2091285 · Cited by 626 · cited 1×
“Hence, the mathematical model of CPL can be obtained by the following equations [40]:”
MethodDC microgrids and distribution systems: An overview
Elsayed, A. T., Mohamed, A. A., & Mohammed, O. A. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2014.10.017 · Cited by 590
DC distribution for industrial systems: opportunities and challenges
Baran, M. E., & Mahajan, N. R. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.818969 · Cited by 582
DC Ring-Bus Microgrid Fault Protection and Identification of Fault Location
Park, J.-D., Candelaria, J., Ma, L., & Dunn, K. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2267750 · Cited by 411
Cited by
Protection Systems for DC Shipboard Microgrids
Bayati, N., & Savaghebi, M. (2021) · Energies · doi:10.3390/en14175319 · Cited by 21
“The fault protection system of a DC MG system typically includes fault detection, location, and isolation [10].”
BackgroundSelf-citation
Metadata
- Authors
- Bayati, N., Hajizadeh, A., & Soltani, M.
- Venue
- IET Smart Grid
- Published
- 2018-09-10
- Volume
- 1
- Issue
- 3
- Pages
- 66-75
- ISSN
- 2515-2947 (ISSN-L)
- OpenAlex
- W2888459562
- Cited by
- 202
- References
- 51
- FWCI
- 13.96
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.