Protection in DC microgrids: a comparative review
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
A direct current (DC) microgrid has become a superior power system in recent years due to the development of DC loads and higher efficiency of DC systems. One of the challenging problems on DC microgrids operation is protection, and it is still a particular concern associated with the challenges of developing a proper protection scheme owing to its characteristics and lack of standards in DC protection. Due to the significant increasing interest on DC microgrid; this study investigates protection problems and schemes that need to be addressed in modern power systems involving DC microgrids. This study analyses and presents a comprehensive review of the most recent growth in the DC microgrids protection. Additionally, the fault characteristics of DC microgrids, the impact of constant power loads, the protection devices and several proposed methods to overcome the protection problems are discussed. The differences between the proposed protection methods for the DC microgrids are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Electronics: Converters, Applications and Design
Mohan, N., Undeland, T. M., & Robbins, W. P. (1989) · Cited by 4,771
VSC-Based HVDC Power Transmission Systems: An Overview
Flourentzou, N., Agelidis, V. G., & Demetriades, G. D. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2008441 · Cited by 2,216 · cited 1×
“However, the disadvantage of the IGBTs is that they are unidirectional protection actuators, hence, IGBTs only can clear faults in the DC line and cannot have an impact on the fault on the converter side [92].”
BackgroundHVDC Circuit Breakers: A Review Identifying Future Research Needs
Franck, C. M. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2095889 · Cited by 909
Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790 · cited 5×
“The steady state fault current is obtained by the following equation [14]:”
BackgroundMethodInfluentialProtection of Low-Voltage DC Microgrids
Salomonsson, D., Soder, L., & Sannino, A. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2016622 · Cited by 712
Locating and Isolating DC Faults in Multi-Terminal DC Systems
Tang, L., & Ooi, B.-T. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2007.899276 · Cited by 640
Dynamic Behavior and Stabilization of DC Microgrids With Instantaneous Constant-Power Loads
Kwasinski, A., & Onwuchekwa, C. N. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2091285 · Cited by 626 · cited 1×
“Hence, the mathematical model of CPL can be obtained by the following equations [40]:”
MethodDC microgrids and distribution systems: An overview
Elsayed, A. T., Mohamed, A. A., & Mohammed, O. A. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2014.10.017 · Cited by 590
DC distribution for industrial systems: opportunities and challenges
Baran, M. E., & Mahajan, N. R. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.818969 · Cited by 582
DC Ring-Bus Microgrid Fault Protection and Identification of Fault Location
Park, J.-D., Candelaria, J., Ma, L., & Dunn, K. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2267750 · Cited by 411
Protection of Nonpermanent Faults on DC Overhead Lines in MMC-Based HVDC Systems
Li, X., Song, Q., Liu, W., Rao, H., Xu, S., & Li, L. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2226249 · Cited by 402
Meyer, J.-M., & Rufer, A. (2006) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.870981 · Cited by 380
Dhar, S., Patnaik, R. K., & Dash, P. K. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2654267 · Cited by 380 · cited 1×
“For instance, in [61], a protection scheme is proposed based on the differential protection strategy for DC microgrids.”
BackgroundOvercurrent Protection on Voltage-Source-Converter-Based Multiterminal DC Distribution Systems
Baran, M. E., & Mahajan, N. R. (2007) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2006.877086 · Cited by 380
A Non-unit Protection Scheme for DC Microgrid Based on Local Measurements
Meghwani, A., Srivastava, S. C., & Chakrabarti, S. (2017) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2016.2555844 · Cited by 351
Wavelet-based protection strategy for DC faults in multi-terminal VSC HVDC systems
De Kerf, K., Srivastava, K., Reza, M., Bekaert, D., Cole, S., Van Hertem, D., & Belmans, R. (2011) · IET Generation, Transmission & Distribution · doi:10.1049/iet-gtd.2010.0587 · Cited by 329 · cited 1×
“Due to this high raising rate of fault, faults in DC microgrids develop with more speed than AC microgrids [36, 37].”
BackgroundGeneral aspects, hierarchical controls and droop methods in microgrids: A review
Planas, E., Gil-de-Muro, A., Andreu, J., Kortabarria, I., & Martínez de Alegría, I. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.09.032 · Cited by 318 · cited 1×
“Batteries, loads and PVs can be easily connected to the DC microgrids without extra inversion stages [21], which can reduce the probability of internal faults.”
BackgroundYao, J., Li, H., Liao, Y., & Chen, Z. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.921177 · Cited by 312 · cited 1×
“Hence, in [117] a control strategy was proposed to limit the DC side voltage during the fault.”
BackgroundYang, J., Fletcher, J. E., & O'Reilly, J. (2010) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2009.2037970 · Cited by 308
Fault Detection and Isolation in Low-Voltage DC-Bus Microgrid System
Park, J.-D., & Candelaria, J. (2013) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2243478 · Cited by 303
Li, W., Monti, A., & Ponci, F. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2313035 · Cited by 294
The Status of DC Micro-Grid Protection
Cuzner, R. M., & Venkataramanan, G. (2008) · 2008 IEEE Industry Applications Society Annual Meeting · doi:10.1109/08ias.2008.382 · Cited by 263 · cited 3×
“Direct current (DC) microgrids have the wide potential for different power applications, such as small-scale generation, backup of energy storages, data centres, marine and other sensitive loads and industrial applications [1, 2].”
BackgroundA review on issues and approaches for microgrid protection
Brearley, B. J., & Prabu, R. R. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.09.047 · Cited by 256 · cited 1×
“Hence, one of the main problems of using microgrids is related to protection issues, because the protection of microgrids may not be solved by conventional methods for several reasons [4] such as bidirectional power flow of microgrids, dynamic characteristics of renewable resources, changing the fault current during i…”
BackgroundVSC-HVDC system protection: A review of current methods
Candelaria, J., & Park, J.-D. (2011) · 2011 IEEE/PES Power Systems Conference and Exposition · doi:10.1109/psce.2011.5772604 · Cited by 206 · cited 1×
“One of the most important devices for the isolating system after faults is the DC CB, various DC CBs have been proposed in [77, 78].”
BackgroundMalekpour, A. R., Niknam, T., Pahwa, A., & Kavousi‐Fard, A. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2218261 · Cited by 197
Fault Analysis on Distribution Feeders With High Penetration of PV Systems
Hooshyar, H., & Baran, M. E. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2227842 · Cited by 184
Al-Nussairi, M. K., Bayındır, R., Padmanaban, S., Mihet‐Popa, L., & Siano, P. (2017) · Energies · doi:10.3390/en10101656 · Cited by 167
Monadi, M., Zamani, M., Candela, J. I., Luna, Á., & Rodríguez, P. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.013 · Cited by 165 · cited 3×
“The impedance and travelling wave methods have been accepted as an industry standard for AC power systems, however, it is difficult to directly implement these methods to the DC microgrids due to the lack of phasor parameters [26].”
BackgroundMethodInfluentialAnalysis and Design of DC System Protection Using Z-Source Circuit Breaker
Chang, A. H., Sennett, B. R., Avestruz, A.-T., Leeb, S. B., & Kirtley, J. L. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2415775 · Cited by 159
Satpathi, K., Ukil, A., & Pou, J. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2017.2788199 · Cited by 137
Cairoli, P., Kondratiev, I., & Dougal, R. A. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2214790 · Cited by 128 · cited 20×
“One of the most important devices for the isolating system after faults is the DC CB, various DC CBs have been proposed in [77, 78].”
MethodInfluentialShi, Y., & Li, H. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2695575 · Cited by 127
Fletcher, S. D. A., Norman, P., Galloway, S., & Burt, G. (2011) · IET Electrical Systems in Transportation · doi:10.1049/iet-est.2010.0070 · Cited by 117
Progress and problems in micro-grid protection schemes
Mirsaeidi, S., Said, D. M., Mustafa, M. W., Habibuddin, M. H., & Ghaffari, K. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.044 · Cited by 111 · cited 3×
“Traditional power systems are normally radial, and because of the unidirectional behaviour of current, they are protected by currentbased relays [44, 45].”
BackgroundInfluentialA Survey on Fault Detection, Isolation, and Reconfiguration Methods in Electric Ship Power Systems
Babaei, M., Shi, J. F., & Abdelwahed, S. (2018) · IEEE Access · doi:10.1109/access.2018.2798505 · Cited by 95 · cited 1×
“All DC microgrids cannot be protected by this method, because this method needs some specific paths for fault current [107].”
MethodThe emitter turn-off thyristor-based DC circuit breaker
Xu, Z., Zhang, B., Sirisukprasert, S., Zhou, X., & Huang, A. Q. (2003) · IEEE Power Engineering Society Winter Meeting · doi:10.1109/pesw.2002.985000 · Cited by 78 · cited 1×
“Furthermore, the emitter turn off (ETO) is a high power switch which is proper for high frequency, high power, and high speed faults [96].”
BackgroundCairoli, P., & Dougal, R. A. (2013) · IEEE Electrification Magazine · doi:10.1109/mele.2013.2291431 · Cited by 74
Protection of AC and DC microgrids: Challenges, solutions and future trends
Beheshtaein, S., Savaghebi, M., Vásquez, J. C., & Guerrero, J. M. (2015) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2015.7392927 · Cited by 69 · cited 2×
“Also, grounding in the DC microgrids must be designed properly to detect the faults [51].”
BackgroundModeling, Control and Protection of Low-Voltage DC Microgrids
Salomonsson, D. (2008) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 60
Fault current limiting power converters for protection of DC microgrids
Cairoli, P., Rodrigues, R., & Zheng, H. (2017) · IEEE SoutheastCon · doi:10.1109/secon.2017.7925392 · Cited by 55 · cited 1×
“DC microgrids provide great advantages in terms of resilience, efficiency, reliability, and flexibility [5].”
BackgroundPeng, C., Song, X., Rezaei, M. A., Huang, X., Widener, C., Huang, A. Q., & Steurer, M. M. (2014) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2014.7049287 · Cited by 55 · cited 1×
“However, the ETO may cause a loss in the system [98].”
BackgroundWavelet based method for fault detection in Medium Voltage DC shipboard power systems
Li, W., Luo, M., Monti, A., & Ponci, F. (2012) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2012.6229382 · Cited by 47 · cited 2×
“A WT fault protection method is proposed in [66].”
MethodDesign and development of a communication-assisted microgrid protection system
Ustun, T. S. (2013) · Victoria University Research Repository (Victoria University) · Cited by 43
Jin, Z., Savaghebi, M., Vásquez, J. C., Meng, L., & Guerrero, J. M. (2016) · International Power Electronics and Motion Control Conference (EPE-PEMC) · doi:10.1109/ipemc.2016.7512282 · Cited by 38 · cited 1×
“• Synchronisation problems are eliminated in DC microgrids [10].”
BackgroundDirectional protection scheme for MVDC shipboard power system
Satpathi, K., Thukral, N., Ukil, A., & Zagrodnik, M. A. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793893 · Cited by 34 · cited 1×
“Therefore, converters can lose the voltage and current control, converters need higher power rating that increases the cost, and cascade tripping in the other protection zones [25].”
BackgroundShort-circuit protection for low-voltage DC microgrids based on solid-state circuit breakers
Munasib, S., & Balda, J. C. (2016) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2016.7527062 · Cited by 31 · cited 1×
“In [101], an IGCT-based protection system was applied to a DC microgrid and used as an reverse blocking IGCT (RB-IGCT).”
MethodEvaluation of the Impact of High-Bandwidth Energy-Storage Systems on DC Protection
Rakhra, P., Norman, P., Fletcher, S. D. A., Galloway, S., & Burt, G. (2015) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2015.2470559 · Cited by 30
Transient voltage and frequency stability of an isolated microgrid based on energy storage systems
Kermani, M. (2016) · IEEE International Conference on Environment and Electrical Engineering and IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe) · doi:10.1109/eeeic.2016.7555871 · Cited by 29 · cited 1×
“In the conventional power systems, the topology of the system is radial [55], and the protection of these systems designed based on unidirectional power flows.”
BackgroundFirefly Algorithm Optimized Robust Protection Scheme for DC Microgrid
Amamra, S.-A., Ahmed, H., & El-Sehiemy, R. A. (2017) · Electric Power Components and Systems · doi:10.1080/15325008.2017.1319435 · Cited by 27
A protection scheme against DC faults VSC based DC systems with bus capacitors
Peng, C., & Huang, A. Q. (2014) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2014.6803800 · Cited by 26 · cited 1×
“Due to this high raising rate of fault, faults in DC microgrids develop with more speed than AC microgrids [36, 37].”
BackgroundEffect of load type on standalone micro grid fault performance
Kamel, R. M., & Nagasaka, K. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.09.044 · Cited by 19
Cited by
Protection Systems for DC Shipboard Microgrids
Bayati, N., & Savaghebi, M. (2021) · Energies · doi:10.3390/en14175319 · Cited by 21
“The fault protection system of a DC MG system typically includes fault detection, location, and isolation [10].”
BackgroundSelf-citation
Metadata
- Authors
- Bayati, N., Hajizadeh, A., & Soltani, M.
- Venue
- IET Smart Grid
- Published
- 2018-09-10
- Volume
- 1
- Issue
- 3
- Pages
- 66-75
- ISSN
- 2515-2947 (ISSN-L)
- OpenAlex
- W2888459562
- Cited by
- 202
- References
- 51
- FWCI
- 13.96
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.