The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Synchronisation methods for grid-connected voltage source converters
Abstract
Four different synchronisation methods for a voltage source converter connected to a three-phase grid are investigated. The methods are adapted for use in a digital controller. The performance of the synchronisation methods is studied by response characteristics of phase-shift steps, frequency steps and low-frequency grid voltage harmonics. The low-pass filtering method can be used only if the frequency of the grid is constant and phase jumps do not occur. If phase jumps occur, the novel space vector filtering method is recommended. The extended space vector filtering method is adapted to handle frequency variations and is also preferred if fast frequency variations occur. This method even has a higher performance than the extended Kalman filter method, in spite of the large number of calculations that must be performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase-locked loop techniques. A survey
Hsieh, G.-C., & Hung, J. C. (1996) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.544547 · Cited by 784
Fast assessment methods for voltage sags in distribution systems
Bollen, M. (2002) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1995.530593 · Cited by 127
Fast assessment methods for voltage sags in distribution systems
Bollen, M. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.556647 · Cited by 126
Cited by
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Decoupled Double Synchronous Reference Frame PLL for Power Converters Control
Rodriguez, P., Pou, J., Bergas, J., Candela, J. I., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890000 · Cited by 1,359
Power-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
Self-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit
Zhong, Q.-C., Nguyen, P.-L., Ma, Z., & Sheng, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2258684 · Cited by 1,026
Gnanarathna, U. N., Gole, A. M., & Jayasinghe, R. P. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2060737 · Cited by 739
Virtual Inertia: Current Trends and Future Directions
Tamrakar, U., Shrestha, D., Maharjan, M., Bhattarai, B., Hansen, T., & Tonkoski, R. (2017) · Applied Sciences · doi:10.3390/app7070654 · Cited by 640
Karimi-Ghartemani, M., & Iravani, M. R. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.831280 · Cited by 575
Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design Guidelines
Golestan, S., Ramezani, M., Guerrero, J. M., Freijedo, F. D., & Monfared, M. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2273461 · Cited by 564
Timbus, A., Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE 36th Conference on Power Electronics Specialists, 2005. · doi:10.1109/pesc.2005.1581980 · Cited by 347
Metadata
- Authors
- Svensson, J.
- Venue
- IEE Proceedings - Generation, Transmission and Distribution
- Published
- 2001
- Volume
- 148
- Issue
- 3
- Pages
- 229
- ISSN
- 1350-2360 (ISSN-L)
- OpenAlex
- W2075997616
- Cited by
- 284
- References
- 4
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.